We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable PGA Multifilament Suture 1/2 Circle Cylindrical Trocar Point (Tapercut) HRT 26 mm | USP 2/0 (Metric 3) | Violet Grooved Thread 75 cm | Ref. 112HRT2620 | Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament suture of 100% polyglycolic acid (PGA) from the Premisut range, mounted on a ½ circle needle with cylindrical body and trocar point (tapercut) of 26 mm (HRT 26), USP gauge 2/0 (metric 3) and braided thread violet grooved of 75 cm. Coated with polycaprolactone and calcium stearate for smooth glide and maximum knot security. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures and general surgery. Ref. 112HRT2620 (SKU AM112HRT2620) in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM112HRT2620

Description

1. Commercial Introduction

The absorbable multifilament suture of polyglycolic acid (PGA), reference 112HRT2620 from the Premisut range, is the trusted choice for the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery. Its ½ circle needle with cylindrical body and trocar point (tapercut) of 26 mm ensures clean penetration in moderately tense tissues with contained trauma, while the violet braided fluted 75 cm thread offers optimal visibility over the surgical field.

It is a synthetic, absorbable, sterile and single-use medical device, with an excellent price-quality ratio for the B2B supply of operating theatres, clinics, purchasing centres and distributors of surgical material. Commercial presentation in a box of 12 units and a minimum order of 30 boxes to ensure the continuous supply of your healthcare centre.

2. Technical explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration regularises the surface of the thread, favours sliding through tissue, reduces the sawing effect and guarantees a firm and secure knot tie, even in medium working gauges such as USP 2/0 (metric 3).

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, which the body metabolises without generating relevant tissue reaction, completing between 60 and 90 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance.

The HRT 26 needle features a ½ circle curvature with cylindrical body and trocar point (tapercut geometry): a convergent triangular-section tip that combines firm penetration in moderately tense or slightly fibrous tissues with minimal tissue tearing as the thread passes. The violet colour improves visibility of the thread throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference 112HRT2620 (SKU AM112HRT2620)

Parameter Specification
Factory reference / SKU 112HRT2620 · AM112HRT2620
Range / quality Premisut (standard quality)
Material 100 % synthetic absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge / size USP 2/0 (metric 3), in accordance with USP/EP Pharmacopoeia
Approximate diameter 0.30 – 0.349 mm (indicative according to Pharmacopoeia)
Thread colour Fluted violet (colourless version available in the range)
Thread length 75 cm, 1 needle per thread
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Tapercut (converging triangular cross-section)
Needle size HRT 26 mm (26 mm)
Absorption mechanism Hydrolysis, completed between 60 and 90 days
Sterilisation Ethylene oxide (EtO); sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Commercial presentation Box of 12 units; minimum order of 30 boxes

3.2. Tensile strength retention profile after implantation

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60-90 days, by hydrolysis

Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a totally predictable and controlled absorption rate.

3.3. Size equivalence

USP size Metric size Approximate diameter
2/0 (this product) 3 0.30 – 0.349 mm (indicative according to Pharmacopoeia)
3/0 2 0.20 – 0.249 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm

4. Equivalences and Cross-References

Coated braided multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. Having verified the documentation of the main comparable manufacturers, no official equivalence table from the manufacturer has been found for a 1:1 cross-reference with the exact configuration of this reference (HRT 26 mm tapercut needle, USP 2/0 gauge, 75 cm thread and violet colour); the reference cited below is a catalogue comparison confirmed against authorised distribution, not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) Coated VICRYL (coated braided polyglactin 910), violet, USP 2/0, 75 cm, ½ circle MH-1 tapercut needle W9136 Comparable by category (not interchangeable 1:1) Confirmed in reference catalogue and authorised distribution: they match in USP 2/0 gauge, violet colour, 75 cm length, ½ circle shape and tapercut point family; they differ in polymer (polyglactin 910 vs 100% PGA), the nomenclature and exact needle size (MH-1 vs HRT 26) and the absorption profile (56-72 days vs 60-90 days).

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As comparable market families to verify reference by reference in their official data sheet before a substitution, the following lines are cited: 100% PGA braided coated —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), Assucryl PGA (Assut), Atramat PGA (Internacional Farmacéutica) and the historical Dexon (limited availability)— and polyglactin 910 —Vicryl / Vicryl Plus (Ethicon), Polysorb (Medtronic), Novosyn (B. Braun)—, always checking USP 2/0 gauge, 26 mm needle size in ½ circle, trocar point, 75 cm thread length and violet colour. The polyglactin 910 (PGLA) copolymer ranges are chemically distinct from homopolymer PGA and should not be treated as interchangeable 1:1 without validation by the pharmacy service or technical department. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference. Within the Cahnos catalogue, the same HRT 26 needle configuration in polyglactin 910 (absorption 56-72 days) corresponds to reference 1L18HRT2620 (USP 2/0, violet, 70 cm).

5. Selection tips and variants of interest

The USP 2/0 gauge (metric 3) offers an ideal balance between initial strength and manageability for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligation of medium-calibre vessels. The ½ circle trocar point (tapercut) HRT 26 needle is the right choice for firm or slightly fibrous tissues where clean penetration without tearing is required; if the tissue is soft or friable, consider the conical point (HR) variant of the same PGA family.

Reference Variant of interest
AM112HRT2620 Standard PGA, HRT26 trocar point needle, USP 2/0, violet, 75 cm (current product)
AMP112HRT2620 PGA Prime, same HRT26 configuration, USP 2/0, violet, 75 cm (premium range)
AM112HRT2630 Same HRT26 needle, USP 3/0 gauge, violet, 75 cm (finer gauge)
AM112HR2620 Standard PGA HR26 conical point, USP 2/0, violet, 75 cm (atraumatic point)
AM112HS2620 Standard PGA HS26 reverse cutting triangular point, USP 2/0, violet, 75 cm (firm tissues)
1L18HRT2620 Polyglactin 910 (PGLA) HRT26, USP 2/0, violet, 70 cm (absorption 56-72 days)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, handle the strand with gloves to avoid altering its mechanical properties, and keep the reference together with the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

100 % synthetic absorbable polyglycolic acid (PGA)

Structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

USP size

2/0 (metric 3)

Metric gauge (EP)

3

Thread diameter

0.30 – 0.349 mm (indicative per USP/EP Pharmacopoeia)

Thread colour

Fluted violet (colourless version available in the range)

Needle size

HRT 26 mm (26 mm), 1 needle per suture

Sterilisation

Ethylene oxide (EtO); single-use, not resterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Regulatory standard

Conforms to USP and European Pharmacopoeia gauges

Manufacturer reference

112HRT2620

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HRT 26

Usp

2/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical, Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable PGA Multifilament Suture 1/2 Circle Cylindrical Trocar Point (Tapercut) HRT 26 mm | USP 2/0 (Metric 3) | Violet Grooved Thread 75 cm | Ref. 112HRT2620 | Box of 12 units”

Your email address will not be published. Required fields are marked *