Absorbable Multifilament PGA Suture (Polyglycolic Acid) · Needle ½ Circle Cylindrical Body Trocar Point HRT17 (17 mm) · USP Size 4/0 · Undyed Thread 70 cm · Ref. 128HRT1740 · Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Synthetic absorbable multifilament suture of 100% polyglycolic acid (PGA) with an atraumatic ½ circle needle, cylindrical body and 17 mm trocar point (HRT17), coated with polycaprolactone and calcium stearate. USP size 4/0 (metric 1.5), undyed grooved thread, 70 cm. Predictable absorption by hydrolysis between 60 and 90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures and general surgery. Presentation in a box of 12 units; minimum order of 30 boxes. Ref. 128HRT1740 · SKU AM128HRT1740.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM128HRT1740

Description

1. Commercial Introduction

The absorbable multifilament suture of polyglycolic acid (PGA) is the synthetic resorbable solution of medium duration demanded by general surgery, gynaecology, urology and major ambulatory surgery services: a braided, flexible thread with a totally predictable absorption profile, ideal for the approximation of soft tissues, ligatures and closures in deep and superficial planes.

This presentation incorporates a ½ circle needle with a cylindrical body and trocar point of 17 mm (HRT17), colourless thread of 70 cm and USP gauge 4/0. Designed for operating theatres, clinics and purchasing centres, it is supplied in a box of 12 sterile units with batch traceability, constant quality and B2B conditions for volume buyers.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration regularises the surface of the thread: it favours a smooth passage through the tissue, reduces the sawing effect, offers excellent handleability and guarantees great security in knot tying, even in fine working gauges such as USP 4/0.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, which the body metabolises without generating relevant tissue reaction. Absorption is completed between 60 and 90 days, maintaining 75% of the initial tensile strength at 2 weeks, 50% at 3 and 40% at 4.

The HRT17 needle has a ½ circle curvature with a cylindrical body and trocar point (convergent triangular section): it combines firm penetration in tissues of moderate tension or slightly fibrous with minimal tissue tearing when passing the strand. The colourless colour facilitates visualisation of the surgical field and its use in superficial planes with minimal visual interference. The product is supplied sterile by ethylene oxide (EtO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference 128HRT1740 (SKU AM128HRT1740)

Parameter Specification
Factory reference / SKU 128HRT1740 · AM128HRT1740
Suture type Synthetic absorbable braided multifilament
Material 100 % synthetic absorbable polyglycolic acid (PGA)
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament with grooved finish
Gauge / size USP 4/0 (metric 1.5), conforming to USP/EP Pharmacopoeia
Approximate thread diameter 0.15 – 0.199 mm (indicative according to Pharmacopoeia)
Thread colour Undyed (violet version available in the range)
Thread length 70 cm, with a single needle (1 needle per thread)
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Trocar (converging triangular section)
Needle size HRT17 (17 mm)
Absorption mechanism Hydrolysis, completed between 60 and 90 days
Sterilisation Ethylene oxide (EtO); sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Commercial presentation Box of 12 units; minimum order of 30 boxes
Regulatory standard Gauges in accordance with USP and European Pharmacopoeia (EP)

3.2. Tensile strength retention profile after implantation

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60 – 90 days, by hydrolysis

Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a totally predictable and controlled reabsorption rate.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)

USP size Metric size Approximate diameter
4/0 (this product) 1.5 0.15 – 0.199 mm (indicative according to Pharmacopoeia)
3/0 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.349 mm
0 3.5 0.35 – 0.399 mm

4. Equivalences and Cross-References

Coated braided multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable on the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. For the exact configuration of this reference (HRT17 ½ circle needle with 17 mm trocar point, USP gauge 4/0, colourless 70 cm thread) no verified catalogue correspondence has been found in a primary source that reproduces point by point all the characteristics against third-party brands, so no exact 1:1 equivalence with other commercial houses is declared.

Within the same manufacturer (Premisut range), the variants with identical needle geometry, gauge and length are:

Reference (SKU) Variant of interest Equivalence level
AM118HRT1740 Standard PGA, HRT17 trocar point needle, USP 4/0, violet thread, 70 cm (same configuration, colour with greater visibility) Exact reference equivalence (same manufacturer)
AMP128HRT1740 Superior range PGA, HRT17 trocar point needle, USP 4/0, colourless thread, 70 cm Exact reference equivalence (same manufacturer)
AMP118HRT1740 Superior range PGA, HRT17 trocar point needle, USP 4/0, violet thread, 70 cm Exact reference equivalence (same manufacturer)
1L28HRT1740 Standard polyglactin 910 (PGLA), HRT17 trocar point, USP 4/0, colourless thread, 70 cm (absorption 56-72 days, different copolymer) Comparable by category (not interchangeable 1:1)
P1L28HRT1740 Premium polyglactin 910 (PGLA) range, HRT17 trocar point, USP 4/0, colourless thread, 70 cm (absorption 56-72 days, different copolymer) Comparable by category (not interchangeable 1:1)

There is no equivalence table validated by the manufacturer against third-party brands for this specific configuration; consult the technical department before use in tenders. As homologous market families to be verified reference by reference in their official datasheet before a substitution, the lines of 100% braided coated PGA are cited —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH) and Atramat PGA— and those of polyglactin 910 —Vicryl (Ethicon) and Polysorb (Medtronic)—, always checking USP gauge 4/0, needle size of 17 mm in ½ circle, trocar point, thread length of 70 cm and colourless colour. The copolymer ranges of polyglactin 910 (PGLA) are chemically different from PGA homopolymer and should not be treated as interchangeable 1:1 without validation from the pharmacy service or the technical department. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

The USP gauge 4/0 (metric 1.5) is ideal for fine tissues and low-medium tension: skin approximation, subcutaneous tissue, mucous membranes, microsurgery and ligatures of small-calibre vessels. The ½ circle needle with HRT17 trocar point is recommended for firm or slightly fibrous tissues where clean penetration without tearing is required; if the tissue is soft or friable, consider the conical point HR17 variant of the same family (ref. AM128HR1740).

If maximum visibility over the surgical field is preferred, the violet version of identical configuration is available (ref. AM118HRT1740). For tissues with prolonged healing, the standard absorption polyglactin 910 line may be considered (ref. 1L28HRT1740, absorption 56-72 days) and, for a shorter arc curvature, the version with a ⅜ circle needle and 17 mm trocar point (ref. AMP128DRT1740).

As it is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, handle the strand with gloves so as not to alter its mechanical properties and keep the reference together with the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer reference

128HRT1740

Material

100 % synthetic absorbable polyglycolic acid (PGA)

Coating

Polycaprolactone and calcium stearate

Thread structure

Multifilament braided coated (fluted)

USP size

4/0 (metric 1.5)

Thread diameter

0.15 – 0.199 mm (indicative according to Pharmacopoeia)

Swaged

Single needle (1 needle per thread)

Needle body

Cylindrical

Needle tip

Trocar (converging triangular section)

Needle size

17 mm (HRT17)

Sterilisation

Ethylene oxide (EtO); single-use, not re-sterilisable

Presentation

Box of 12 units

Minimum order

30 boxes

Regulatory standard

Gauges in accordance with USP and European Pharmacopoeia (EP)

Indications

Tissue approximation, ligatures and general surgery

Medida de aguja

HRT 17

Usp

4/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable, Absorbable medium (46–120 days)