We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) | ½ Circle Needle Cylindrical Body Taperpoint Conical Point HR 40 mm | Gauge USP 1 (Metric 4) | Violet Grooved Thread 90 cm | Ref. 113HR4001 (SKU AM113HR4001) – Box of 12 units

Original price was: 34,90 €.Current price is: 26,25 €.

Absorbable multifilament suture of polyglycolic acid (PGA) 100% synthetic, coated with polycaprolactone and calcium stearate for smooth passage through tissue and a firm, secure knot. It features a ½ circle needle, cylindrical body and 40 mm Taperpoint conical point (HR 40), gauge USP 1 (metric 4), violet grooved thread of 90 cm. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Product sterilised by ethylene oxide, single-use and with minimal tissue reaction, indicated for tissue approximation, ligatures and general surgery. Manufacturer ref. 113HR4001 · SKU AM113HR4001. Presentation in box of 12 units; price per box.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM113HR4001

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture, reference 113HR4001 (SKU AM113HR4001), is the reference surgical closure solution for hospitals, general surgery operating theatres, private clinics and B2B purchasing centres looking for a high-performance absorbable synthetic thread with an excellent quality-price ratio.

Its ½ circle needle with cylindrical body and 40 mm Taperpoint conical point penetrates soft tissues by separating the fibres without cutting them, which minimises trauma and makes it especially suitable for tissue approximation, ligatures and general surgery. Each unit is supplied sterile, ready to use and in a box of 12 units.

2. Technical explanation of the product and procedure

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a structure of braided multifilament with grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces the sawing effect, offers very smooth handling, low memory and firm, secure knot tying, even in medium-high diameter gauges such as USP 1.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, without depending on the patient’s enzymatic activity. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues that require support for 2 to 4 weeks of healing while they recover their own strength.

The ½ circle needle with cylindrical body and Taperpoint conical point penetrates by separating the fibres without cutting them, which minimises trauma to soft tissues; the grooved violet colouration ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide; sterile single-use product and not re-sterilisable.

3. Technical Specifications

3.1. General characteristics of reference 113HR4001

Reference (SKU Cahnos) AM113HR4001 · Manufacturer ref. 113HR4001
Material 100% Polyglycolic Acid (PGA) multifilament, with a coating of polycaprolactone and calcium stearate
Thread structure Braided multifilament with grooved finish (grooved)
Gauge USP 1 (metric 4)
Thread colour Violet (also available colourless)
Thread length 90 cm (1 thread, 1 needle)
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Conical (Taperpoint), tapered and atraumatic
Needle size 40 mm (HR 40 profile)
Absorption mechanism Hydrolysis
Absorption period 60 – 90 days
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Tissue reaction Minimal, with excellent tensile strength and knot security
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile unit)

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %
Total absorption 60 – 90 days (by hydrolysis)

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
2/0 3 0.30 – 0.349 mm
0 3.5 0.35 – 0.399 mm
1 (this product) 4 0.40 – 0.499 mm
2 5 0.50 – 0.599 mm

4. Equivalences and Cross-References

The polyglycolic acid (PGA) suture belongs to the family of synthetic absorbable braided sutures with medium absorption. By polymer composition (PGA homopolymer), braided structure, coating, hydrolysis absorption profile (60-90 days) and tensile retention, it is comparable at category level (not 1:1 interchangeable) with the following homologous configuration on the international market, verified in the manufacturer’s catalogue and authorised distribution:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson) Coated VICRYL (braided coated polyglactin 910, violet) J331H Comparable by category (not interchangeable 1:1) USP 1, violet thread 90 cm and CT-2 taper point needle 40 mm in ½ circle; gauge, colour, curvature and point match. The polymer differs (PGLA 90/10 copolymer versus PGA homopolymer) and the absorption window (56-72 days versus 60-90 days). Verified on the manufacturer’s website and authorised distribution.

Other homologous families of 100% braided coated PGA that must be verified field by field (gauge, thread length, needle radius and point, coating and absorption window) before any formal substitution: Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), Dexon II (Medtronic/Covidien, limited availability), Resorba and the HR/TC needle series from European laboratories. The copolymeric polyglactin 910 ranges (Vicryl, Polysorb, Novosyn, Safil Quick) are chemically different from PGA homopolymer and should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department.

There is no equivalence table validated by the manufacturer that cross-references this configuration (PGA USP 1, HR 40 mm conical needle, 90 cm violet thread) with closed codes from other commercial houses; consult the technical department before using in tendering.

5. Selection tips and variants of interest

USP 1 gauge (metric 4) is indicated for tissues requiring high initial strength: fascia, aponeurosis, muscle planes, abdominal wall and moderate-high tension closures. The ½ circle Taperpoint conical point needle separates the fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt point, while for fibrous and dense structures the trocar point is recommended. Also verify the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area to be treated.

Reference Variant of interest
AM113HR4001 PGA USP 1, conical needle HR 40 mm, violet, 90 cm (current product)
AMP113HR4001 PGA Prime USP 1, same HR 40 mm needle, violet, 90 cm (higher range, same configuration)
1L13HR4001 PGLA (polyglactin 910) USP 1, HR 40 mm needle, violet, 90 cm (absorption 56-72 days)
AM113HR4010 PGA USP 0, same HR 40 mm needle, violet, 90 cm (finer gauge)
AM113HR4002 PGA USP 2, same HR 40 mm needle, violet, 90 cm (larger gauge)
AM118HR4001 PGA USP 1, HR 40 mm needle, violet, 70 cm (shorter thread)
AM113HR4801 PGA USP 1, HR 48 mm needle, violet, 90 cm (larger needle radius)

If the procedure requires longer wound support (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For B2B volume conditions, hospital supply contracts or equivalence validation for tenders, contact our technical-commercial team.

Additional information

Manufacturer reference

113HR4001

Material

100% Polyglycolic Acid (PGA) braided multifilament coated with polycaprolactone and calcium stearate

Thread structure

Braided multifilament with grooved finish

Gauge

USP 1 (metric 4)

Needle body

Cylindrical

Needle tip

Taperpoint conical

Needle size

HR 40 mm (1 needle per strand)

Absorption mechanism

Hydrolysis

Strength retention

75% at 2 weeks; 50% at 3 weeks; 40% at 4 weeks

Sterilisation

Ethylene oxide; sterile, single-use, not re-sterilisable

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 units

Medida de aguja

HR 40

Usp

1

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) | ½ Circle Needle Cylindrical Body Taperpoint Conical Point HR 40 mm | Gauge USP 1 (Metric 4) | Violet Grooved Thread 90 cm | Ref. 113HR4001 (SKU AM113HR4001) – Box of 12 units”

Your email address will not be published. Required fields are marked *