Description
1. Commercial Introduction
The Absorbable Multifilament PGA Prime Suture from the PREMISUT range, list reference P118HR3601, is the trusted solution for B2B supply to operating theatres, purchasing centres and hospital tenders. It combines a braided polyglycolic acid (PGA) thread, 100% absorbable, in gauge USP 1 with a ½ circle needle, cylindrical body and Taperpoint conical point of 36 mm (HR36 profile), the reference format for approximating soft tissues and ligatures in general surgery of medium tension. Violet non-grooved thread of 70 cm, sterile and single-use, presented in a box of 12 units with batch traceability.
2. Technical Explanation
The thread is made of polyglycolic acid (PGA), a linear-chain synthetic polyester that degrades by hydrolysis with fully predictable kinetics independent of the patient’s enzymatic activity: mass absorption is complete between 60 and 90 days, while tensile strength is maintained during the critical phase of wound healing (75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks).
The coating of polycaprolactone and calcium stearate reduces friction and the sawing effect on tissue, improves thread sliding and facilitates knot seating with excellent knot security. The Prime finish (non-grooved surface) prevents the capillary effect and optimises passage through tissue.
The HR36 needle of ½ circle with cylindrical body and Taperpoint conical point traverses soft tissues atraumatically: the conical point penetrates by separating the fibres without aggressive cutting effect, avoiding enlargement of the exit hole and minimising haemorrhage. Its 36 mm length makes it ideal for deep planes and medium-sized surgical fields in general, abdominal and gynaecological surgery. The violet colour ensures immediate visibility on the surgical field. Product sterile by ethylene oxide (EO), single-use and non-resterilisable, conforming to USP/EP pharmacopoeias for sterile absorbable sutures.
3. Technical Specifications
3.1. Technical data sheet for the reference (Ref. P118HR3601 · SKU AMP118HR3601)
| Parameter | Specification |
|---|---|
| Brand / quality | PREMISUT PRIME (premium range of multifilament suture) |
| Factory reference | P118HR3601 |
| Reference Cahnos (SKU) | AMP118HR3601 |
| Thread material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided multifilament, non-grooved surface (Prime) |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 1 (metric EP 4); diameter 0.40 – 0.499 mm (USP/EP Pharmacopoeia) |
| Thread length | 70 cm (free end) |
| Thread colour | Violet |
| Needle shape | ½ circle (1/2 circular) |
| Tip type | Conical Taperpoint (atraumatic), cylindrical body |
| Needle size | 36 mm (HR36 profile), 1 needle per thread |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | By hydrolysis; complete mass absorption in 60-90 days |
| Tensile strength retention | 75% (2 weeks) · 50% (3 weeks) · 40% (4 weeks) |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets, batch traceability); minimum order 30 units |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures |
3.2. Tensile strength and absorption profile
| Period | Remaining tensile strength | Absorption |
|---|---|---|
| 2 weeks | Approximately 75 % | — |
| 3 weeks | Approximately 50 % | — |
| 4 weeks | Approximately 40 % | — |
| 60-90 days | — | Complete absorption by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2 | 5 | 0.50 – 0.599 mm |
| 1 (this product) | 4 | 0.40 – 0.499 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
4. Equivalences and Cross-References
The reference P118HR3601 corresponds to the official nomenclature of the PREMISUT PRIME range (HR36 profile: ½ circle cylindrical needle with Taperpoint conical point of 36 mm, USP 1 gauge, violet thread of 70 cm, armed with 1 needle) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
The braided multifilament polyglycolic acid (PGA) of medium absorption (60-90 days) belongs to one of the most standardised families of synthetic absorbable suture on the market. However, there is no manufacturer-validated equivalence table that cross-references this specific configuration with references from other houses; the following row is offered as a functional comparison verified against the manufacturer’s official catalogue and GUDID/FDA database, and must be validated against the IFU before any substitution. As it is another brand, it does not constitute an exact reference equivalence (reserved for the same manufacturer).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® (polyglactin 910) – violet braided, CT-1 needle of 36 mm, ½ circle taper, USP 1, 70 cm (27″) | J341H | Comparable by category (not interchangeable 1:1) | They match in USP 1 gauge, ½ circle taper needle and 36 mm, length 70 cm, violet colour and braided structure. They differ in material (polyglactin 910 – copolymer of glycolide/lactide – versus 100% PGA), coating and absorption kinetics (56-72 days versus 60-90 days). Code confirmed in the official Ethicon catalogue and GUDID/FDA. |
The remaining homologous lines of the braided PGA segment —Safil® (B. Braun), Surgicryl® PGA (SMI), Dexon II and European distribution ranges— must be reviewed property by property (material, USP/metric gauge, curvature, point family, needle size, arming, thread length, colour and CE/MDR regulatory classification) before any substitution; no cross-reference codes not verified in an official source are published.
There is no manufacturer-validated equivalence table that cross-references this reference with other brands; consult the technical department of Cahnos before using in tendering or direct substitution. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
Tissue to suture: USP 1 gauge (metric EP 4; diameter 0.40-0.499 mm) is the choice for soft tissues of medium-high tension: aponeurosis, muscle planes, deep subcutaneous tissue, ligatures of medium-calibre vessels and laparotomy closures. The HR36 needle of ½ circle with Taperpoint conical point combines the sharp entry of the point with the non-traumatic passage of the cylindrical body: it is the recommended option when seeking an atraumatic passage, without cutting effect and with minimal haemorrhage.
Variants within the PREMISUT system: the same HR36 Taperpoint geometry is available in other gauges (e.g. USP 0 and USP 2/0) and lengths within the PGA Prime range, as well as in an undyed thread version for protocols that prefer to avoid the pigment. For an absorption profile with polyglactin 910 kinetics (56-72 days instead of 60-90 days), the PREMISUT Polyglactin range offers equivalent configurations with the same needle; note that the polymer composition changes and it is not interchangeable for indication purposes without clinical validation.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the pouch and the expiry date before each procedure, keep the reference P118HR3601 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.