We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) | Needle ½ Circle Cylindrical Body Blunt Point HRN 40 mm – USP 1 (Metric 4) Gauge | Violet Braided Thread 90 cm | Ref. 113HRN4001H – Box of 12 units

Original price was: 39,90 €.Current price is: 28,30 €.

Multifilament absorbable suture of 100% polyglycolic acid (PGA), mounted with a ½ circle needle, cylindrical body and atraumatic blunt point of 40 mm (HRN 40). USP 1 (metric 4) gauge, violet braided thread of 90 cm, sterile by ethylene oxide and predictable absorption by hydrolysis between 60 and 90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Coated with polycaprolactone and calcium stearate for smooth glide and firm, secure knot tying, with minimal tissue reaction. Indicated for tissue approximation, ligatures and general surgery. Reference 113HRN4001H (SKU AM113HRN4001H), presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM113HRN4001H

Description

1. Commercial Introduction

The Prime-quality absorbable multifilament polyglycolic acid (PGA) suture is the reference surgical closure solution for professionals requiring a reliable, flexible synthetic thread with a fully predictable absorption profile. It is supplied with a ½-circle needle, cylindrical body and blunt (atraumatic) point of 40 mm (HRN 40), USP 1 gauge and a 90 cm violet grooved thread.

Each unit is supplied sterile and ready to use, with the professional distribution guarantee of Cahnos for hospitals, private clinics, operating theatres and purchasing groups. It is especially indicated for tissue approximation, ligatures and a wide range of general surgery procedures, where precision, handling and a constant absorption rate during the first weeks of healing are required. Reference 113HRN4001H, SKU AM113HRN4001H.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer composed of 100% glycolide units, presented in a braided multifilament structure with a grooved finish. This configuration provides great flexibility, low shape memory and a contained friction coefficient, which favours thread sliding through tissue and knot tying with maximum security, also thanks to the polycaprolactone and calcium stearate coating.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days. The thread maintains constant wound support: it retains 75% of the initial tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, while the tissue recovers its own resistance; an ideal profile for tissues requiring support during the first weeks of healing.

The ½-circle needle with cylindrical body and blunt point (reinforced, heavy version) penetrates tissues by separating fibres without cutting them, which minimises the risk of tearing and makes it especially recommended for delicate and friable structures, vascular ligatures and soft tissue approximation. The violet grooved colouring ensures optimal visibility in the surgical field. Sterile single-use product, not suitable for re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference 113HRN4001H

Characteristic Specification
Material 100 % Polyglycolic Acid (PGA), synthetic absorbable
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 1 (metric 4)
Thread colour Violet grooved
Thread length 90 cm
Needle: shape ½ circle
Needle: body Cylindrical
Needle: point Roma (atraumatic, heavy version)
Needle: size HRN 40 mm, 1 needle per strand
Absorption mechanism Hydrolysis
Absorption period 60–90 days
Sterilisation Ethylene oxide (EO); single-use, non-reesterilizable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile sachets)
Minimum order 30 boxes
Regulatory standard Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures
Reference (SKU) 113HRN4001H · AM113HRN4001H

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Complete absorption 60–90 days (by hydrolysis)

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Sterilised by ethylene oxide. Price per box of 12 units.

4. Equivalences and Cross-References

Braided polyglycolic acid (PGA) is one of the most widely used families of medium-absorption synthetic absorbable sutures on the international market. There is no manufacturer-validated equivalence table for cross-brand substitution in the exact configuration of ½-circle needle, cylindrical body, blunt point HRN 40 mm, USP 1 gauge and 90 cm thread; consult the technical department before use in tenders.

At family level, the reference homologous lines in the sector are Safil (pure braided polyglycolic acid, violet) from B. Braun, Dexon / Dexon II (braided polyglycolic acid) from Medtronic, and the braided PGA ranges from European houses such as Surgicryl (SMI) or the polyglycolic acid series from Laboratorio Aragó. For the copolymer polyglactin 910 (PGLA), the reference homologous line is Vicryl from Ethicon (braided coated polyglactin 910, violet colour). All are comparable at category level (same type of base polymer and absorption profile), but not interchangeable 1:1: for any formal substitution, the exact material, gauge (USP 1), needle size and geometry (½ circle, cylindrical body, blunt point, 40 mm radius), thread length (90 cm), colour and regulatory classification of each reference must be verified one by one, since small variations in needle radius or point profile prevent direct equivalence. No confirmed external reference code for this exact configuration has been found in official sources from other commercial houses; specific codes must be confirmed with each manufacturer.

Within the Cahnos catalogue, the reference sharing the complete configuration (HRN 40 mm blunt point needle, USP 1, violet, 90 cm) in reinforced quality is AMP113HRN4001H (PGA Prime Heavy), and in the polyglactin 910 family the alternatives are 1L13HRN4001H (PGLA Heavy) and P1L13HRN4001H (PGLA Prime Heavy), which differ only in the base polymer and absorption period (56–72 days). There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.

5. Selection tips and variants of interest

USP 1 gauge (metric 4) is indicated for tissues requiring high initial strength: aponeurosis, fascia, muscle planes and high-tension closures, maintaining predictable absorption during a healing period of 2 to 4 weeks. The blunt point (HRN) is the most atraumatic option for delicate tissues; the conical point (HR) facilitates penetration into soft tissues and the trocar point (HRT) is reserved for denser, more fibrous structures.

Reference Variant of interest
AM113HRN4001H PGA USP 1, blunt point HRN 40 mm, violet, 90 cm (current product)
AMP113HRN4001H PGA Prime Heavy USP 1, same HRN 40 mm needle, violet, 90 cm (reinforced quality)
AM113HRN4010H PGA Heavy USP 0, same HRN 40 mm needle, violet, 90 cm (finer gauge)
AMP113HRN4010H PGA Prime Heavy USP 0, same HRN 40 mm needle, violet, 90 cm
AMP113HRN3601H PGA Prime Heavy USP 1, blunt point HRN 36 mm, violet, 90 cm (smaller needle radius)
AM113HR4001 PGA USP 1, conical point HR 40 mm, violet, 90 cm (easier penetration)
1L13HRN4801 PGLA USP 1, blunt point HRN 48 mm, violet, 90 cm (larger radius needle)

If the procedure requires longer wound support (180–210 days), the polydioxanone (PDO) family is the recommended alternative. Always check the integrity of the packaging before each intervention, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or confirmation of equivalences for tendering, contact our technical-commercial team.

Additional information

Material

100 % Polyglycolic Acid (PGA), synthetic absorbable

Structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

Gauge

USP 1 (metric 4)

Colour

Violet grooved

Needle body

Cylindrical

Needle tip

Roma (atraumatic, heavy version)

Needle size

HRN 40 mm (1 needle per suture)

Sterilisation

Ethylene oxide (EO); single-use, non-reesterilizable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

30 boxes

Regulatory standard

Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures

Manufacturer reference

113HRN4001H

Medida de aguja

HRN 40

Usp

1

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Blunt tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) | Needle ½ Circle Cylindrical Body Blunt Point HRN 40 mm – USP 1 (Metric 4) Gauge | Violet Braided Thread 90 cm | Ref. 113HRN4001H – Box of 12 units”

Your email address will not be published. Required fields are marked *