Description
1. Commercial Introduction
The multifilament absorbable suture of polyglycolic acid (PGA) reference 113HRN4010H (SKU AM113HRN4010H) is the reference surgical closure solution for hospitals, operating theatres, private clinics and purchasing centres seeking a reliable, flexible synthetic absorbable thread with a fully predictable absorption rate. Its ½ circle needle with cylindrical body and 40 mm blunt point in heavy version (HRN 40) penetrates tissues by separating fibres without cutting them, minimising trauma and making it especially suitable for delicate and friable tissues.
This is a synthetic, absorbable, ethylene oxide sterilised, single-use medical device with excellent value for money for B2B procurement and tenders. It is supplied in a box of 12 units with a minimum order of 30 boxes, ensuring a continuous and traceable supply for your facility.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish. Its coating of polycaprolactone and calcium stearate improves thread glide through tissue, reduces friction and the sawing effect, and facilitates firm, secure knot tying with high initial tensile strength.
Absorption occurs by hydrolysis, i.e. by controlled degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, metabolised by the body with minimal tissue reaction. The thread provides constant wound support: it retains 75 % of initial tensile strength at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks, while the tissue recovers its own strength.
The ½ circle needle (approx. 180°) with cylindrical body and blunt point in reinforced version (heavy) penetrates tissues by separating fibres without cutting them, reducing the risk of tearing and making it especially recommended for delicate structures, vascular ligatures and approximation of soft tissues. The violet colour improves thread visibility throughout the procedure. Single-use sterile product, not for re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference 113HRN4010H
| Parameter | Specification |
| Factory reference | 113HRN4010H |
| Reference (SKU) | AM113HRN4010H |
| Range / Quality | PREMISUT – Normal quality (needle heavy version) |
| Composition | 100% synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 0 (metric 3.5 – EP) |
| Thread colour | Violet grooved |
| Thread length | 90 cm |
| Needle shape | ½ circle (approx. 180°) |
| Needle body | Cylindrical |
| Needle tip | Roma (atraumatic, heavy version) |
| Needle size | HRN 40 mm, 1 needle per strand |
| Absorption mechanism | Hydrolysis (60–90 days) |
| Sterilisation | Ethylene oxide (EO); single-use, non-reesterilizable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 boxes |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Complete absorption | 60–90 days (by hydrolysis) |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Ethylene oxide sterilised. Price per box of 12 units.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding its limits.
4. Equivalences and Cross-References
Braided polyglycolic acid (PGA) is one of the most widespread families of medium-absorption synthetic absorbable sutures on the international market. There is no equivalence table validated by the manufacturer for cross-referencing between brands in the exact configuration of ½ circle needle, cylindrical body, blunt point HRN 40 mm heavy, USP 0 gauge and 90 cm thread; consult the technical department before use in a tender.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| B. Braun | Safil® (pure braided coated polyglycolic acid, violet, absorption 60–90 days) | Not verified | Comparable by category (not interchangeable 1:1) | Material and absorption profile very similar to PGA (homopolymer and 60–90 days), but no confirmed official code has been found for the exact configuration blunt point HRN 40 mm heavy / USP 0 / 90 cm / violet. Verify in the manufacturer’s catalogue or GUDID. |
| Medtronic / Covidien | Dexon® / Dexon II® (braided polyglycolic acid) | Not verified | Comparable by category (not interchangeable 1:1) | Same clinical category of medium-absorption synthetic absorbable braided suture, without confirmed code against official source for this exact configuration. |
| Ethicon (Johnson & Johnson) | VICRYL® (coated braided polyglactin 910, violet) | Not verified | Comparable by category (not interchangeable 1:1) | They share a coated braided structure, USP 0 gauge and atraumatic needle geometry, but differ in polymer (90/10 glycolide/L-lactide copolymer vs PGA homopolymer) and declared absorption (56–70 days for VICRYL vs 60–90 days for PGA). Verify code with the manufacturer. |
Other manufacturers with homologous families of medium-absorption braided PGA: SMI (Surgicryl® PGA), Assut, Glicosorb and Atramat from Laboratorio Aragó. All are comparable at the category level (same base polymer and absorption profile), but not interchangeable 1:1: for any formal substitution, the exact material, gauge (USP 0), needle size and geometry (½ circle, cylindrical body, blunt point, 40 mm radius, heavy version), thread length (90 cm), colour and regulatory classification of each reference must be verified one by one.
Within the Cahnos catalogue, its direct equivalent in complete configuration is AMP113HRN4010H (PGA Prime Heavy, same HRN 40 mm blunt point needle, USP 0, violet, 90 cm, superior quality), and in the polyglactin 910 family the alternative with the same needle is 1L13HRN4010H (PGLA Heavy, absorption 56–72 days). There is no equivalence table validated by the manufacturer; consult the technical department before use in a tender.
5. Selection tips and variants of interest
USP 0 (metric 3.5) gauge is highly versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and ligation of medium-calibre vessels, with an excellent balance between initial strength and predictable absorption during healing of 2 to 4 weeks. The blunt point (HRN) is the most atraumatic option for delicate and friable tissues; the conical point (HR) facilitates penetration into soft tissues and the trocar point (HRT) is reserved for denser and more fibrous structures (fascia, aponeurosis, sclera).
| Reference (SKU) | Variant of interest |
| AM113HRN4010H (113HRN4010H) | PGA USP 0, blunt point HRN 40 mm Heavy, violet, 90 cm (current product) |
| AMP113HRN4010H | PGA Prime Heavy USP 0, same HRN 40 mm needle, violet, 90 cm (superior quality) |
| AM113HRN4001H | PGA USP 1, same HRN 40 mm needle, violet, 90 cm (larger gauge) |
| AMP113HRN4001H | PGA Prime Heavy USP 1, same HRN 40 mm needle, violet, 90 cm |
| 1L13HRN4010H | PGLA USP 0, blunt point HRN 40 mm Heavy, violet, 90 cm (absorption 56–72 days) |
| P1L13HRN4010H | PGLA Prime Heavy USP 0, same HRN 40 mm needle, violet, 90 cm |
| AM113HRT4010 | PGA USP 0, trocar point HRT 40 mm, violet, 90 cm (fibrous tissues) |
| AMP112HRN4010 | PGA Prime USP 0, blunt point HRN 40 mm, violet, 75 cm (shorter thread) |
If the procedure requires longer wound support (180–210 days), the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units. As this is sterile single-use material, always check the integrity of the packaging before each procedure, respect the expiry date and store in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or confirmation of equivalences for tenders, contact our technical-commercial team.





Reviews