Description
1. Commercial Introduction
The absorbable multifilament suture of polyglycolic acid (PGA) from the Prime range, reference AMP118HS2230, is the surgical closure solution that the professional demands when looking for a synthetic thread with predictable behaviour, excellent handling and maximum security in knot tying. Its ½ circle needle with reverse cutting triangular point of 22 mm guarantees firm and controlled penetration in medium-consistency tissues, while the 70 cm violet grooved braided thread offers optimal visibility on the surgical field and smooth sliding during suturing.
It is a synthetic, absorbable, sterile and single-use medical device, with a very competitive quality-performance ratio for B2B procurement of operating theatres, general surgery services and purchasing centres. Commercial presentation in a box of 12 units.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is an absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and coated with polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, reduces the sawing effect, offers smooth handling and guarantees firm and secure knot tying even in fine gauges such as USP 3/0.
Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, with complete reabsorption in a period of 60 to 90 days. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, the time necessary for the tissue to recover its own resistance. The ½ circle needle with reverse cutting triangular point concentrates the cutting edge on the outer face of the curvature: it penetrates firm and non-compliant tissues with a clean and controlled cut, without tearing the surrounding tissue. The product is supplied sterile by ethylene oxide and must not be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AMP118HS2230
| Parameter | Specification |
| Range / quality | Prime (premium range multifilament) |
| Factory reference (series) | P118HS2230 · SKU Cahnos AMP118HS2230 |
| Material | 100 % synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 3/0 (metric 2) |
| Approximate diameter | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
| Thread colour | Violet |
| Thread length | 70 cm |
| Needle shape | ½ circle (1/2 circular) |
| Tip type | Triangular reverse cutting (reverse cutting), triangular body and point |
| Needle size | HS 22 (22 mm), 1 needle per thread |
| Absorption mechanism | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Complete absorption | 60 – 90 days (hydrolysis) |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable and controlled absorption rate.
4. Equivalences and Cross-References
Braided and coated multifilament polyglycolic acid (PGA) is the most widely used synthetic absorbable of medium duration in the surgical market. The following homologous PGA families with similar configuration (USP 3/0 gauge, violet thread of 70-75 cm and reverse cutting needle) have been verified in public sources (GUDID/FDA, official catalogues and authorised distributors):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Safil® (braided coated PGA, violet) | C1048235 | Comparable by category (not interchangeable 1:1) | Verified in GUDID/FDA: SAFIL VIOLET 3/0 (2) 70 cm. PGA material, USP 3/0 gauge and 70 cm length match; needle curvature (⅜ circle vs ½ circle HS22) and coating (glyconate vs polycaprolactone and calcium stearate) differ. |
| SMI (Surgical Materials Industries) | Surgicryl® PGA (coated polyglycolic acid) | 11201524 | Comparable by category (not interchangeable 1:1) | Same PGA polymer, same coating and USP 3/0 gauge (EP 2) with reverse cutting needle; they differ in curvature (⅜ vs ½), needle size (24 mm vs 22 mm) and thread length (75 cm vs 70 cm). |
| DemeTECH Corporation | DemeSORB® PGA (coated braided multifilament) | PGA283024F4P | Comparable by category (not interchangeable 1:1) | USP 3/0, violet, 75 cm thread and 24 mm reverse cutting needle; they differ in curvature (⅜ vs ½), needle size (24 mm vs 22 mm) and thread length (75 cm vs 70 cm). |
There is no equivalence table validated by the manufacturer for the specific configuration of ½ circle HS 22 mm needle; consult the technical department before use in tenders. The indicated equivalences are functional category comparisons, not 1:1 interchangeable: before replacing this reference, the material, USP gauge, curvature (½ circle), point family (reverse cutting triangular), needle size (22 mm), thread length (70 cm), colour and coating must be verified one by one in the corresponding manufacturer’s technical data sheet or IFU. The copolymer ranges of polyglactin 910 (PGLA), such as Vicryl® (Ethicon), Safil® 910 (B. Braun) or Polysorb® (Medtronic), are chemically different from PGA homopolymer (absorption 56 to 72 days vs 60-90 days) and should not be treated as 1:1 interchangeable without validation from the pharmacy service or technical department.
5. Selection tips and variants of interest
USP 3/0 gauge (metric 2) offers an ideal balance between initial strength and handling for soft and medium-consistency tissues: skin, subcutaneous tissue, mucosa, tissue approximation and ligatures in general surgery. The ½ circle needle with 22 mm reverse cutting triangular point (HS 22) is especially recommended when firm tissues need to be penetrated with a clean passage and without tearing, and the violet thread provides maximum visibility on the surgical field. Consult the variants of the same family to adjust quality, colour, gauge or geometry to each procedure:
| Reference | Variant of interest |
| AM118HS2230 | Standard PGA USP 3/0, ½ triangular HS22 mm needle, violet, 70 cm (economical alternative) |
| AMP128HS2230 | PGA Prime USP 3/0, same HS22 mm needle, colourless, 70 cm (maximum aesthetic discretion) |
| AMP118HS2220 | PGA Prime USP 2/0, same HS22 mm needle, violet, 70 cm (larger gauge for more tension) |
| P1L18HS2230 | PGLA Prime USP 3/0, HS22 mm needle, violet, 70 cm (absorption 56-72 days) |
| 1L18HS2230 | Standard PGLA USP 3/0, HS22 mm needle, violet, 70 cm (copolymer range) |
| P1L18HS2630 | PGLA Prime USP 3/0, triangular HS26 mm needle, violet, 70 cm (larger needle size) |
All references are supplied in boxes of 12 units with a minimum order of 30 boxes. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact our technical-commercial team.