Description
1. Commercial Introduction
The Absorbable Multifilament PGA Suture from the PREMISUT line, reference 118HS2230, is the reference surgical closure solution for operating theatres, general surgery departments, minor surgery units and purchasing centres that demand a synthetic absorbable suture with predictable behaviour, excellent handling and maximum knot security. Its ½ circle needle with 22 mm reverse cutting triangular point (HS22) ensures firm, controlled penetration in medium-consistency tissues, while the 70 cm violet braided fluted thread offers optimal visibility over the surgical field and smooth sliding during suturing.
It is a synthetic, absorbable, sterile, single-use medical device, with excellent value for money for the B2B supply of hospitals, clinics and distributors of surgical material. Packaging: box of 12 units.
2. Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a fluted finish and coated with polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, reduces the sawing effect, offers smooth handling and guarantees firm, secure knot tying, even in fine gauges such as USP 3/0.
Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, with complete reabsorption in a period of 60 to 90 days. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, the time necessary for the tissue to recover its own resistance. The ½ circle needle with reverse cutting triangular point concentrates the cutting edge on the outer curve: it passes through firm and non-compliant tissues with a clean, controlled cut, without tearing the surrounding tissue. The violet colour improves contrast on the surgical field. The product is supplied sterile by ethylene oxide and must not be resterilised.
3. Technical Specifications
3.1. Technical data sheet for reference 118HS2230
| Parameter | Specification |
| Brand / Range | PREMISUT (standard quality) |
| Factory reference | 118HS2230 |
| Reference Cahnos (SKU) | AM118HS2230 |
| Material | 100% polyglycolic acid (PGA), absorbable by hydrolysis |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 3/0 (metric 2) |
| Approximate diameter | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
| Thread colour | Violet |
| Thread length | 70 cm |
| Needle shape | ½ circle (1/2 circular) |
| Tip type | Reverse cutting triangular, triangular body and point |
| Needle size | HS22 (22 mm), 1 needle per suture |
| Absorption mechanism | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Complete absorption | 60 – 90 days (hydrolysis) |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 3/0 | 2 | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Braided coated multifilament polyglycolic acid (PGA) is the most widely used medium-term synthetic absorbable in the surgical market. The following homologous PGA families with a close configuration (USP gauge 3/0, violet thread 70-75 cm and reverse cutting needle) have been verified in public sources (official catalogues, GUDID/FDA regulatory databases and authorised distributors):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Safil® (braided coated PGA, violet) | C1048235 | Comparable by category (not interchangeable 1:1) | Verified in GUDID/FDA: SAFIL VIOLET 3/0 (2) 70CM DS24. They match PGA material, USP gauge 3/0 and length of 70 cm; they differ in needle curvature (⅜ circle DS24 vs. ½ circle HS22) and coating (glyconate vs. polycaprolactone and calcium stearate). |
| SMI (Surgical Materials Industries) | Surgicryl® PGA (coated polyglycolic acid) | 11201524 | Comparable by category (not interchangeable 1:1) | Verified in authorised distributors: same PGA polymer, coating of polycaprolactone and calcium stearate, USP gauge 3/0 (EP 2) and reverse cutting needle; they differ in curvature (⅜ vs. ½), needle size (DS24 of 24 mm vs. HS22 of 22 mm) and thread length (75 cm vs. 70 cm). |
| DemeTECH Corporation | DemeSORB® PGA (coated braided multifilament) | PGA283024F4P | Comparable by category (not interchangeable 1:1) | Verified in the manufacturer’s official store: USP 3/0, violet, thread 75 cm (30 inches) and 24 mm reverse cutting needle (DFS-1); they differ in curvature (⅜ vs. ½), needle size (24 mm vs. 22 mm) and thread length (75 cm vs. 70 cm). |
There is no equivalence table validated by the manufacturer for the ½ circle HS22 22 mm needle configuration; consult the technical department before use in tenders. The equivalences indicated are functional category comparisons, not 1:1 interchangeable: before replacing this reference, the material, USP gauge, curvature (½ circle), point family (reverse cutting triangular), needle size (22 mm), thread length (70 cm), colour and coating must be verified one by one in the corresponding manufacturer’s technical data sheet or IFU. Copolymer ranges of polyglactin 910 (PGLA), such as Vicryl® (Ethicon) or Novosyn® (B. Braun), and those of polyglactin Safil® 910 (B. Braun) or Polysorb® (Medtronic), are chemically different from PGA homopolymer (absorption 56 to 72 days vs. 60-90 days) and should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department.
5. Selection tips and variants of interest
USP gauge 3/0 (metric 2) offers an ideal balance between initial strength and handling for soft and medium-consistency tissues, subcutaneous planes, tissue approximation and ligatures. The ½ circle needle with 22 mm reverse cutting triangular point (HS22) is especially recommended when firm tissues need to be penetrated with a clean pass and without tearing, and the violet thread provides maximum visibility on the surgical field. Consult the variants of the same family to adjust quality, colour, gauge or geometry to each procedure:
| Reference | Variant of interest |
| AM118HS2230 | PGA standard USP 3/0, ½ triangular needle HS22 mm, violet, 70 cm (current product) |
| AMP118HS2230 | PGA Prime USP 3/0, same configuration HS22 mm, violet, 70 cm (premium range) |
| AM128HS2230 | PGA standard USP 3/0, same needle HS22 mm, undyed, 70 cm (maximum aesthetic discretion) |
| AMP128HS2230 | PGA Prime USP 3/0, same needle HS22 mm, undyed, 70 cm (Prime undyed) |
| AM118HS4020 | PGA standard USP 2/0, ½ triangular needle HS40 mm, violet, 70 cm (larger gauge and larger needle size) |
| AM112DS2430 | PGA standard USP 3/0, ⅜ triangular needle DS24 mm, violet, 75 cm (⅜ curvature and longer length) |
All references are supplied in boxes of 12 units. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, store it in a cool, dry place protected from sunlight, and respect the expiry date. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours made to order, contact our technical-commercial team at Cahnos.