Description
1. Commercial Introduction
The PGA multifilament absorbable suture from the PREMISUT range is the reference solution in the operating theatre for professionals seeking a reliable, predictable synthetic absorbable thread with an excellent cost-performance ratio in B2B supply. Its ½ circular needle with a 48 mm (HS48) reverse cutting triangular point ensures firm, controlled penetration even in dense tissues, while the 90 cm violet fluted thread offers optimal visibility on the surgical field and excellent handling with every stitch.
It is a sterile, single-use medical device with minimal tissue reaction, excellent tensile strength and optimal knot security. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes, ideal for the continuous supply of hospitals, clinics and purchasing centres.
2. Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a fluted finish. Its coating of polycaprolactone and calcium stearate improves thread glide through tissue, reduces friction and facilitates firm, secure knot tying, even in medium-diameter gauges such as USP 0 (metric 3.5).
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. The ½ circle needle with a triangular reverse cutting body and point of 48 mm penetrates firm, dense tissues (skin, fascia, aponeurosis) with controlled trauma, minimising damage at the entry point. The product is sterilised by ethylene oxide and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference 113HS4810
| Reference (SKU) | 113HS4810 (AM113HS4810) |
| Material | 100 % synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Violet grooved |
| Needle shape | ½ circle |
| Tip type | Reverse cutting triangular (body and point) |
| Needle size | 48 mm (HS 48) |
| Thread length | 90 cm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60-90 days |
| Sterilisation | Ethylene oxide (EO); single-use, non-reesterilizable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Complete absorption | 60-90 days (by hydrolysis) |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the most widely used medium-duration braided multifilament absorbable on the market. This reference shares the absorption profile (60-90 days), strength retention, coated braided structure, USP 0 gauge, HS 48 mm ½ circle reverse cutting needle and 90 cm length with the main homologous families of medium-absorption braided absorbable suture. Comparison with polymers other than PGA homopolymer is made at category level:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson) | VICRYL (braided polyglactin 910, violet, 90 cm, CPX ½ circle reverse cutting needle 48 mm, USP 0) | V1057H | Comparable by category (not interchangeable 1:1) | Copolymer composition 90/10 glycolide/L-lactide versus PGA homopolymer; declared absorption 56-70 days; same HS/reverse cutting needle of 48 mm, USP 0, violet and 90 cm. Code verified in catalogues of authorised distributors; consult the manufacturer’s technical data sheet before substituting. |
Other commercial houses with homologous families of medium-absorption braided absorbable suture offer products in the same clinical category, but no confirmed reference code is available for this exact configuration (USP 0 / HS 48 mm / 90 cm), so they are cited as families, not as closed equivalences: B. Braun with its Safil line (pure polyglycolic acid, absorption profile 60-90 days very similar to PGA homopolymer), Medtronic with the Polysorb range and SMI with Surgicryl PGA. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and closures requiring a balance between initial strength and delicacy. The reverse cutting triangular point (HS) is recommended for penetrating firm, dense tissues without tearing (skin, fascia, aponeurosis); if the tissue is soft or friable, consider the conical point (HR).
| Reference | Variant of interest |
| AM113HS4810 | PGA USP 0, HS 48 mm triangular needle, violet, 90 cm (current product) |
| AMP113HS4810 | PGA Prime USP 0, same HS 48 mm needle, violet, 90 cm (Prime quality) |
| AM113HS4801 | PGA USP 1, same HS 48 mm needle, violet, 90 cm (larger gauge) |
| AM113HS4802 | PGA USP 2, same HS 48 mm needle, violet, 90 cm (higher strength) |
| AM113HS4010 | PGA USP 0, HS 40 mm triangular needle, violet, 90 cm (shorter needle) |
| AM113HR4810 | PGA USP 0, cylindrical needle with HR 48 mm conical point, violet, 90 cm (soft tissues) |
| 1L13HS4810 | PGLA polyglactin 910 USP 0, HS 48 mm triangular needle, violet, 90 cm (alternative polymer) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews