We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture USP 2/0 1/2 Circle Reverse Cutting Triangular Needle 36 mm (HS 36) Violet 90 cm

Original price was: 44,90 €.Current price is: 32,60 €.

Absorbable multifilament suture 100% polyglycolic acid (PGA) from the Prime range, with a ½ circle reverse cutting triangular point needle of 36 mm (HS 36), USP 2/0 gauge and 90 cm grooved violet thread. Predictable absorption by hydrolysis in 60-90 days, tensile strength retention of 75% at 2 weeks and polycaprolactone and calcium stearate coating for smooth passage and secure knot tying. Sterile by ethylene oxide, minimal tissue reaction. Ideal for tissue approximation, ligatures and general surgery. Reference P113HS3620 (SKU AMP113HS3620) in a box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP113HS3620

Description

1. Product Presentation

The absorbable multifilament polyglycolic acid (PGA) suture from the Prime range is the professional solution for surgery requiring controlled reabsorption, excellent handling and consistent knot security. With a ½ circle reverse cutting triangular point needle of 36 mm (HS 36), USP 2/0 gauge and 90 cm violet grooved thread, this reference offers predictable clinical performance in tissue approximation, ligatures and general surgery procedures. It is supplied in a box of 12 units, being a high-quality alternative with an excellent cost-performance ratio for hospitals, clinics and purchasing centres.

2. Technical Explanation

Polyglycolic acid (PGA) is a biocompatible synthetic polymer configured in a braided multifilament structure with a grooved finish. This architecture regularises the surface of the thread, facilitates passage through tissue and allows firm, secure knot tying. Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, providing wound support during the first critical weeks of healing. The ½ circle needle with reverse cutting triangular point (reverse cutting) penetrates firm, non-compliant tissues with controlled trauma and without tearing, while the violet colour ensures optimal visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference AMP113HS3620

Characteristic Specification
Material 100% synthetic absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Quality Prime (Premisut range)
Gauge USP 2/0 (metric 3)
Colour Violet
Needle shape ½ circle
Tip type Reverse cutting triangular (reverse cutting)
Needle size 36 mm (HS 36)
Thread length 90 cm
Absorption mechanism Hydrolysis (60-90 days)
Sterilisation Ethylene oxide (EO)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units
Reference (SKU) AMP113HS3620

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %

Complete absorption by hydrolysis between 60 and 90 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.

4. Equivalences and Cross-References

Polyglycolic acid (PGA) is the most established homopolymeric raw material for braided synthetic absorbable suture on the market. Clinically, this reference belongs to the same family as the international braided PGA lines: Dexon (PGA from Medtronic/Covidien), the Safil range from B. Braun (PGA with 60-90 day absorption) and Assucryl (Assut Sutures). At a functional category level, it is also related to polyglactin 910 (PGLA) lines such as Vicryl (Ethicon), Novosyn (B. Braun) or Polysorb (Medtronic), although these are copolymers of glycolide and lactide with a somewhat shorter absorption profile (56-72 days) and should not be treated as interchangeable 1:1 without validation from the centre’s purchasing committee.

There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. Within the Cahnos catalogue, its direct comparables in the same HS 36 mm configuration are: the colourless PGA version AMP123HS3620, and in the PGLA family the references P1L13HS3620 (violet) and P1L23HS3620 (colourless), all with a 36 mm triangular needle, 2/0 gauge and 90 cm of thread.

5. Selection tips and variants of interest

USP 2/0 gauge (metric 3) is indicated for soft tissues under moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures. The reverse cutting triangular point needle is the recommended choice for firm, non-compliant tissues, where a clean passage without tearing is required. If the procedure requires less passage trauma in delicate tissues, consider the cylindrical variant with a conical point; if you prefer greater field visibility, the colourless version; and if healing requires longer support, consult the polydioxanone (PDO) family, with absorption of 180 to 210 days.

Reference Variant
AMP113HS3620 PGA Prime USP 2/0, HS 36 mm triangular needle, violet, 90 cm (current product)
AMP123HS3620 PGA Prime USP 2/0, same HS 36 mm needle, colourless, 90 cm
AMP113HR3620 PGA Prime USP 2/0, HR 36 mm cylindrical needle (conical point, more atraumatic)
AMP112HS3620 PGA Prime USP 2/0, HS 36 mm needle, violet, 75 cm
AMP113HS3610 PGA Prime USP 0, HS 36 mm needle, violet, 90 cm (larger gauge)
P1L13HS3620 PGLA Prime USP 2/0, HS 36 mm needle, violet, 90 cm (absorption 56-72 days)
P1L23HS3620 PGLA Prime USP 2/0, HS 36 mm needle, colourless, 90 cm

All references are supplied in boxes of 12 units. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglycolic acid (PGA) 100 % synthetic

Structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2/0 (metric 3)

Needle tip

Triangular reverse cutting (reverse cutting)

Needle size

36 mm (HS 36)

Absorption mechanism

Hydrolysis (60-90 days)

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units

Manufacturer reference

P113HS3620

Medida de aguja

HS 36

Usp

2/0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Tipo uso

Single-use

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture USP 2/0 1/2 Circle Reverse Cutting Triangular Needle 36 mm (HS 36) Violet 90 cm”

Your email address will not be published. Required fields are marked *