Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture from the Prime range, reference P112HS2620, is the trusted solution for professionals seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery. Its ½ circle needle with reverse cutting triangular point of 26 mm (HS 26) ensures firm and controlled penetration in tissues of certain consistency, while the ribbed violet braided thread of 75 cm offers optimal visibility on the surgical field and smooth sliding throughout the suture.
It is a synthetic, absorbable, sterile and single-use medical device, with an excellent price-quality ratio for the B2B supply of operating theatres, clinics, purchasing centres and distributors of surgical material. Commercial presentation in a box of 12 units to guarantee continuous supply to the healthcare centre.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a ribbed finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that favours the passage of the thread through tissue, reduces the sawing effect, offers smooth handling and guarantees firm and secure knot tying, even in medium working sizes such as USP 2/0.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing (75 % at 2 weeks, 50 % at 3 and 40 % at 4), while the tissue recovers its own resistance.
The ½ circle 26 mm needle with reverse cutting triangular body and point penetrates firm and non-compliant tissues (skin, fascia, aponeurosis) with controlled trauma and without tearing, which makes it especially suitable for skin closures, ligatures and surgical fields with limited access. The violet colour improves the visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference P112HS2620 (SKU AMP112HS2620)
| Parameter | Specification |
| Brand / Range | Prime (premium multifilament range) |
| Factory reference | P112HS2620 · SKU Cahnos AMP112HS2620 |
| Material | 100 % Polyglycolic Acid (PGA) synthetic absorbable |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2/0 (metric 3) |
| Approximate diameter | 0.30 – 0.349 mm (indicative according to USP/EP) |
| Thread colour | Fluted violet (colourless version available in the range) |
| Thread length | 75 cm |
| Needle shape | ½ circle (approx. 180°) |
| Needle tip | Triangular with reverse cutting (triangular body and point) |
| Needle size | HS 26 (26 mm), 1 needle per suture |
| Absorption mechanism | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Regulatory standard | USP / European Pharmacopoeia (EP) |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Complete absorption | 60 – 90 days (hydrolysis) |
Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable and controlled absorption rate.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 2/0 (this product) | 3 | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
Braided and coated multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days. The following equivalent range has been verified in the official catalogue of the manufacturer SMI (Surgical Materials Industries, Belgium) by composition (PGA homopolymer coated with polycaprolactone and calcium stearate), gauge, needle geometry, colour and thread length:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| SMI (Surgical Materials Industries, Belgium) | Surgicryl® PGA (polyglycolic acid, coated braided multifilament) | 11201426 (HS 26 needle, 26 mm, ½ circle, reverse cutting) | Comparable by category (not interchangeable 1:1) | Official SMI catalogue: material (PGA coated with polycaprolactone and calcium stearate), USP 2/0 gauge, ½ circle reverse cutting needle of 26 mm, violet thread of 75 cm and absorption of 60-90 days all match. The needle nomenclature and commercial presentation differ, so it is not interchangeable 1:1 without prior validation by the technical department. |
Other homologous polyglycolic acid families without a confirmed reference code for this exact configuration (HS 26 mm ½ circle needle with reverse cutting triangular point, USP 2/0, violet, 75 cm), such as DemeTECH DemeSORB® PGA, B. Braun Safil® (violet PGA) or Atramat® PGA (International Farmacéutica), must be checked case by case in their technical data sheet: material, USP gauge, needle size (26 mm), ½ curvature, point family (reverse cutting), thread length (75 cm), colour and coating.
There is no equivalence table validated by the manufacturer for this specific configuration (multifilament PGA, ½ circle HS 26 mm needle, reverse cutting triangular point, USP 2/0 gauge, violet thread of 75 cm); consult the technical department before use in tenders. The indicated equivalences are functional category comparisons, not interchangeable 1:1. Copolymer ranges of polyglactin 910 (PGLA), such as Vicryl® (Ethicon), Safil® 910 / Novosyn® (B. Braun) or Polysorb® (Medtronic), are chemically different from PGA homopolymer (absorption of 56 to 72 days versus 60-90 days) and should not be treated as interchangeable 1:1 without validation by the pharmacy service or the technical department.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) offers an ideal balance between initial strength and handling for fine and medium tissues, ligatures, subcutaneous planes and tissue approximation in general surgery. The HS 26 ½ circle needle with reverse cutting triangular point is recommended when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis); if the tissue is soft or friable, consider the conical point variant (HR) of the same family, and if maximum aesthetic discretion is preferred, request the colourless version of the range. Consult the variants in the Cahnos catalogue to adjust gauge, geometry, colour and length to each procedure:
| Reference | Variant of interest |
| AM112HS2620 | Standard PGA USP 2/0, same HS 26 mm configuration, violet, 75 cm (economical alternative) |
| AMP118HS2220 | PGA Prime USP 2/0, HS 22 mm needle, violet, 70 cm (shorter needle) |
| AMP113HS3620 | PGA Prime USP 2/0, HS 36 mm needle, violet, 90 cm (longer needle and thread) |
| AMP123HS3620 | PGA Prime USP 2/0, HS 36 mm needle, undyed, 90 cm (maximum aesthetic discretion) |
| AMP112DS2620 | PGA Prime USP 2/0, ⅜ circle DS 26 mm reverse cutting needle, violet, 75 cm (another curvature) |
| AMP118HS4010 | PGA Prime USP 0, HS 40 mm needle, violet, 70 cm (larger gauge) |
All references are supplied in boxes of 12 units. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.