Description
1. Commercial Introduction
The Prime line absorbable monofilament Polydioxanone (PDO/PDS) suture is the reference choice for professionals who need prolonged tissue support, fully predictable absorption and exceptional thread handling. This presentation combines a 30 cm violet thread in USP 4/0 gauge with a double straight cylindrical needle with a 38 mm trocar point (2xGRT 38), an open surgery configuration designed for precise manual sutures on accessible planes.
Available in a box of 12 sterile units, it is the B2B supply solution for general surgery operating theatres, paediatric cardiovascular surgery units, ophthalmology services and hospital purchasing centres seeking quality homogeneity, complete traceability and consistent performance in every procedure.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals, with complete absorption within 180 to 210 days: one of the longest support windows among absorbable sutures.
Being a non-grooved monofilament, the thread has no wicking effect or interstitial spaces: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with braided threads. The straight needle with a cylindrical body and trocar point (Tapercut type) combines controlled penetration of firm tissues with the atraumatic entry typical of a round-bodied needle, making it especially useful for tissue approximation, ligatures and delicate structures under tension. The violet colour improves thread visibility on the surgical field. Product sterile by ethylene oxide and single-use, not re-sterilisable.
3. Technical Specifications
3.1. Reference tariff data
| Needle size (mm) | USP | Colour | Thread length (cm) | Reference | Box (units) |
| 2xGRT 38 prime | 4/0 | Violet | 30 | P414GRT3840-2 | 12 |
3.2. General characteristics
| Parameter | Specification |
| Factory reference / SKU | P414GRT3840-2 / AMP414GRT3840-2 |
| Material | Polydioxanone (PDO/PDS), synthetic polymer of poly(p-dioxanone) |
| Thread structure | Monofilament, non-channeled |
| USP / metric gauge | 4/0 (metric 2) |
| Thread length | 30 cm |
| Thread colour | Violet (high visibility) |
| Needle shape | Straight |
| Needle body and point | Cylindrical, trocar point (Tapercut) |
| Needle size | 2xGRT 38 – double straight needle, 38 mm per thread |
| Absorption mechanism | Hydrolysis (180-210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
3.3. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75% of initial strength |
| 4 weeks | 60-70% of initial strength |
| 8 weeks | 45% of initial strength |
| Complete absorption | 180-210 days by hydrolysis, with minimal tissue reaction |
This prolonged force retention profile maintains the necessary support during the critical healing phase of slow-healing tissues, which is why it is recommended for closures of planes under sustained traction and in paediatric cardiovascular surgery, where tissue growth is expected.
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market’s reference lines for long-lasting absorbable sutures (PDS-type family). For the verified configuration on this data sheet —double straight cylindrical needle with 38 mm trocar point, USP 4/0 gauge, 30 cm violet thread— no reference from another manufacturer has been found in primary sources (official catalogues, IFUs or regulatory databases such as GUDID/EUDAMED) that matches field by field all the required parameters: material, gauge, double-needle configuration, straight curvature, point family and needle size.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous families on the market, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon (Johnson \u0026 Johnson), the MonoPlus® line from B. Braun/Aesculap (polydioxanone monofilament), the Surgicryl® PDO line from SMI and, with a different polymer (polyglyconate), the Maxon range from Medtronic, whose absorption profile must be confirmed. All of them must be checked field by field: USP gauge, thread length, colour, curvature, body, point and needle size. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and delicate planes —such as this reference—, 3/0 and 2/0 for general soft tissue, and USP 1 and above for fascia and planes under high tension. Needle geometry is also decisive: the straight trocar-point needle (GRT) is recommended for firm tissues of intermediate resistance where trauma is to be minimised, while the conical point (GR) is reserved for soft and delicate tissues and the conventional cutting edge (GS) for superficial fibrous tissues.
Within the Cahnos catalogue you will find interesting variants of the PDO/PDS Prime family with straight needle:
| Reference | Variant of interest |
| P414GRT3840-2 (SKU AMP414GRT3840-2) | Double straight needle, trocar point 38 mm (2xGRT 38), USP 4/0, violet, 30 cm — this reference |
| P414GR1950-2 (SKU AMP414GR1950-2) | Double straight needle, conical point 19 mm (2xGR19), USP 4/0, violet, 30 cm |
| P418GS6040 (SKU AMP418GS6040) | Straight conventional cutting GS60 needle (60 mm), USP 4/0, violet, 70 cm |
| P418GS6030 (SKU AMP418GS6030) | Straight conventional cutting GS60 needle (60 mm), USP 3/0, violet, 70 cm |
As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference and batch number for traceability in the operating theatre. Store in a cool, dry place, below 30 ºC and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.