We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture – Double Straight Needle Conical Point (2xGR19, 19 mm) – USP 4/0 Gauge – Violet Thread 30 cm – Box of 12 units · Ref. P414GR1950-2

62,22 €

Absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line, armed with a double straight needle with conical point of 19 mm (2xGR19, Taperpoint), USP 4/0 gauge and violet non-grooved thread of 30 cm. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 and 45% at 8. The conical point with cylindrical body separates the fibres without cutting them, ideal for soft and delicate tissues: tissue approximation, ligatures, general surgery and paediatric cardiovascular tissues. Sterile by ethylene oxide, single-use, minimal tissue reaction. Presentation in a box of 12 units. Ref. P414GR1950-2.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP414GR1950-2

Description

1. Commercial Introduction

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line is the reference choice when the operating theatre needs prolonged tissue support, fully predictable absorption and exceptional thread handling. This presentation combines a 30 cm violet thread in USP 4/0 gauge with a double straight taper-point 19 mm needle (2xGR19), an open surgery configuration designed for precise manual suturing on accessible tissue planes.

Available in a box of 12 sterile units, it is the B2B supply solution for general surgery departments, paediatric cardiovascular surgery units, ophthalmology services and hospital purchasing centres seeking homogeneity of quality, full traceability and consistent performance in every procedure.

2. Technical Explanation

Polydioxanone is an absorbable synthetic polymer —poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals, with complete absorption within 180 to 210 days: one of the longest support windows among absorbable sutures.

As a non-channelled monofilament, the thread has no wicking effect or interstitial spaces: it reduces bacterial adherence, facilitates sliding through the tissue and minimises the inflammatory response compared with braided threads. The straight needle with cylindrical body and conical point (Taperpoint type) passes through tissue separating the fibres without cutting them, making it especially suitable for soft tissues, fasciae and delicate structures where minimal trauma is desired. The double-needle configuration (one needle at each end of the thread) allows continuous suturing in both directions without rethreading, speeding up the closure of accessible tissue planes. The violet colour improves thread visibility on the surgical field. Product sterile by ethylene oxide and single-use, not resterilisable.

3. Technical Specifications

3.1. Reference tariff data

Needle size (mm) USP Colour Thread length (cm) Reference Box (units)
2xGR19 prime 4/0 Violet 30 P414GR1950-2 12

3.2. General characteristics

Parameter Specification
Factory reference / SKU P414GR1950-2 / AMP414GR1950-2
Material Polydioxanone (PDO/PDS), synthetic polymer of poly(p-dioxanone)
Thread structure Monofilament, non-channeled
USP / metric gauge 4/0 (metric 2)
Thread length 30 cm
Thread colour Violet (high visibility)
Needle shape Straight
Needle body and point Cylindrical, taperpoint conical point
Needle size 2xGR19 – double straight 19 mm needle per thread
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units

3.3. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial strength
4 weeks 60-70% of initial strength
8 weeks 45% of initial strength
Complete absorption 180-210 days by hydrolysis, with minimal tissue reaction

This prolonged force retention profile maintains the necessary support during the critical healing phase of slow-healing tissues, which is why it is recommended for closures of tissue planes under sustained tension and in paediatric cardiovascular surgery, where tissue growth is expected.

4. Equivalences and Cross-References

Polydioxanone monofilament is the material basis of the market’s reference lines for long-lasting absorbable sutures (PDS-type family). For the verified configuration in this data sheet —double straight cylindrical taper-point 19 mm needle, USP 4/0 gauge, 30 cm violet thread— the following homologous reference, comparable at category level and not interchangeable 1:1, has been cross-checked against primary sources (official manufacturer catalogue and authorised distributors):

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® (polydioxanone), double straight cylindrical needle, cylindrical point ST-4, 19 mm (2xST-4), USP 4/0, violet monofilament Z620E Comparable by category (not interchangeable 1:1) Same polymer (polydioxanone), same USP 4/0 gauge, same double straight 19 mm needle configuration and same violet colour. Difference: 35 cm thread (Ethicon) versus 30 cm for this reference; absorption profile according to the Ethicon data sheet of 182-238 days versus 180-210 days for the Prime line. Confirmed in the Ethicon catalogue (EMEA) and authorised distributors.

The other homologous families on the market —Ethicon’s PDS Plus® line, the MonoPlus® line from B. Braun (polydioxanone monofilament), SMI’s Surgicryl® PDO line and, with a different polymer (polyglyconate), the Medtronic Maxon range— must be verified code by code in their official technical data sheet before any substitution: USP gauge, thread length, colour, curvature, body, point and needle size, since small variations prevent a 1:1 equivalence. There is no equivalence table validated by the manufacturer for this specific configuration; consult the technical department before use in tenders. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and delicate planes —like this reference—, 3/0 and 2/0 for general soft tissue, and USP 1 and above for fascia and planes under high tension. Needle geometry is also decisive: the conical point (GR) is reserved for soft and delicate tissues and separates the fibres without cutting them, the trocar point (GRT) for firm tissues of intermediate resistance, and conventional cutting (GS) for superficial fibrous tissues. The double-needle configuration provides versatility by allowing suturing in both directions.

Within the Cahnos catalogue you will find variants of interest from the PDO/PDS family:

Reference Variant of interest
P414GR1950 (SKU AMP414GR1950) Straight taper-point GR19 needle (19 mm), USP 5/0, violet, 30 cm – single end, finer gauge
P414GRT3840-2 (SKU AMP414GRT3840-2) Double straight trocar-point 38 mm needle (2xGRT 38), USP 4/0, violet, 30 cm
AMP418GS6040 Straight conventional cutting GS60 needle (60 mm), USP 4/0, violet, 70 cm
AMP418GS6030 Straight conventional cutting GS60 needle (60 mm), USP 3/0, violet, 70 cm
AMP411GS1340 Straight conventional cutting GS13 needle (13 mm), USP 4/0, violet, 45 cm

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference and batch number for traceability in the operating theatre. Store in a cool, dry place below 30 ºC and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), poly(p-dioxanone) monofilament

Thread structure

Monofilament, non-channeled

USP size

4/0 (metric 2)

Needle type

Straight needle, cylindrical body, conical point (Taperpoint)

Needle size

2xGR19 – double straight 19 mm needle

Absorption mechanism

Hydrolysis, 180-210 days

Sterilisation

Ethylene oxide, single-use

Presentation

Box of 12 sterile units

Manufacturer reference

P414GR1950-2

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Medida de aguja

2xGR 19 prime

Usp

4/0

Color

Violet

Medida de hilo

30 cm

Tipo de aguja

Cylindrical

Forma de aguja

Straight Cut

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture – Double Straight Needle Conical Point (2xGR19, 19 mm) – USP 4/0 Gauge – Violet Thread 30 cm – Box of 12 units · Ref. P414GR1950-2”

Your email address will not be published. Required fields are marked *