We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament PDO/PDS Polydioxanone Suture Prime – Straight Needle GS60 (60 mm) Conventional Cutting · USP Size 3/0 · Violet Thread 70 cm · Box of 12 units · Ref. AMP418GS6030

Original price was: 64,90 €.Current price is: 47,10 €.

Absorbable monofilament Polydioxanone (PDO/PDS) suture from the Prime line, with a straight needle of 60 mm and triangular point in conventional cutting (GS60), USP size 3/0 and smooth violet thread of 70 cm. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 and 45% at 8. Sterilised by ethylene oxide, single-use, minimal tissue reaction and excellent knot tying. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Presentation in a box of 12 sterile units. Ref. P418GS6030 (SKU AMP418GS6030).

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418GS6030

Description

1. Commercial Introduction

The Prime line absorbable monofilament polydioxanone (PDO/PDS) suture is the reference choice when the operating theatre needs a thread with prolonged support, predictable behaviour and maximum security in knot tying. This presentation combines a 70 cm violet thread in USP gauge 3/0 with a 60 mm straight needle and triangular point in conventional cutting (GS60), a configuration designed for firm, controlled penetration in tissues requiring a direct pass without curvature, very common in open surgery on accessible planes.

Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity and complete traceability in each package.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity. This guarantees highly reproducible absorption kinetics between individuals and minimal tissue response, with complete absorption within 180 to 210 days, one of the longest support windows among absorbable sutures.

Being a non-grooved monofilament, the thread has no wicking effect or interstitial spaces: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory reaction compared with braided threads. The straight conventional-cutting needle with triangular point has three cutting edges that pass through firm, fibrous tissues in a straight path, without needing to rotate the wrist, ideal for superficial planes, fascia and structures accessible in the direct field. The violet colour improves thread visibility over the surgical field. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference AMP418GS6030

Parameter Specification
Catalogue reference (Prime line) P418GS6030 (family nomenclature pattern P418GS60xx)
SKU AMP418GS6030
Material Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone), non-grooved
Thread structure Monofilament, non-braided
USP size 3/0
Thread length 70 cm
Thread colour Violet (high visibility)
Needle shape Straight
Needle tip Triangular, conventional cutting
Needle size GS60 – 60 mm, one needle per suture
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (EO); single-use, non-reesterilizable
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial strength
4 weeks 60-70% of initial strength
8 weeks 45% of initial strength
Complete absorption 180-210 days by hydrolysis

This prolonged force retention profile maintains the necessary support during the critical healing phase of slow-healing tissues, which is why it is recommended for closures of fascia, aponeurosis and structures subject to sustained tension, as well as in paediatric cardiovascular surgery where tissue growth is expected.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration in this data sheet (60 mm conventional-cutting straight needle with triangular point, USP gauge 3/0, 70 cm violet thread), a verified homologous market reference has been located in primary sources with which it shares material and measurements:

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson) PDS II® (polydioxanone, monofilament) Z663H Comparable by category (not interchangeable 1:1) USP gauge 3/0 and 60 mm straight needle with 70 cm thread, but it is marketed undyed (clear), KS straight needle (reverse cutting as opposed to GS conventional cutting) and presentation in a box of 36 units. Verify point, colour and packaging before substituting.

As homologous market families to be verified code by code before any substitution: Ethicon’s PDS II® and PDS Plus® lines, the MonoPlus® line from B. Braun/Aesculap (monofilament polydioxanone), SMI’s Surgicryl® PDO line and Medtronic’s Maxon range (polyglyconate). It should be noted that, in Ethicon’s official catalogue, the straight cutting needle of the PDS II family (KS model, 60 mm, 70 cm) is only marketed in undyed colour and in USP gauges 3/0 and 4/0 (refs. Z663H and Z662H), so it is not interchangeable 1:1 with this violet reference. All alternatives must be checked against their official technical data sheet: USP gauge, thread length, colour, curvature, body, point and needle measurement. There is no equivalence table validated by the manufacturer for this configuration; consult the technical department before use in tenders. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue and moderate tension planes, and USP 1 and above for fascia, aponeurosis and structures under high tension. The needle shape is also decisive: the straight needle is handled directly with the hand or a straight needle holder and is especially practical in superficial planes and accessible fields; the conventional-cutting triangular point is indicated for firm, fibrous tissues, while the conical point is reserved for delicate, well-perfused tissues (vessels, parenchyma) and the trocar point for intermediate tissues.

In the Cahnos catalogue you will find the PDO/PDS Prime family in other gauges of the same GS60 format (AMP418GS6020 in 2/0 and AMP418GS6040 in 4/0), the standard quality version AM418GS6030, as well as ½ circle needles with conical point and trocar point, double needle and loop format, always in a box of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference and batch number for traceability in the operating theatre. Store in a cool, dry place, below 30 °C and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone), non-grooved

Needle type

Straight

Needle tip

Triangular – conventional cutting

Needle size

GS60 (60 mm)

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Manufacturer reference

P418GS6030

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 sterile units

Minimum order

30 boxes

Medida de aguja

GS 60

Usp

3/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Conventional triangular

Forma de aguja

Straight Cut

Calidad sutura

Prime

Estructura hilo

Braided multifilament

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament PDO/PDS Polydioxanone Suture Prime – Straight Needle GS60 (60 mm) Conventional Cutting · USP Size 3/0 · Violet Thread 70 cm · Box of 12 units · Ref. AMP418GS6030”

Your email address will not be published. Required fields are marked *