Description
1. Commercial Introduction
The absorbable monofilament polydioxanone (PDO/PDS) suture is the technical reference for prolonged absorption for professionals requiring extended wound support, predictable handling and maximum knot security. This presentation combines a 75 cm grooved violet thread in USP 3/0 gauge with a ⅜ circle needle with a reverse cutting triangular body and point of 26 mm (DS26), a geometry designed to penetrate fibrous tissue with a clean passage, without tearing and with minimal tissue damage.
It is the B2B supply solution for operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology services and hospital purchasing centres. Synthetic absorbable medical device, sterile and single-use, supplied in a box of 12 units.
2. Technical explanation
Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals, completing between 180 and 210 days. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilament.
The ⅜ circle needle (approximate curvature of 135°) with a reverse cutting triangular point (reverse cutting) has the cutting edge on the outer side of the curve, which prevents tearing of superficial tissue and makes it especially suitable for skin, subcutaneous tissue, aponeurosis and other fibrous planes. The grooved violet colour improves thread visibility on the surgical field and knot holding. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Range | PREMISUT (standard quality) |
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Grooved monofilament |
| Gauge / size | USP 3/0 (metric 2) |
| Approximate diameter | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
| Thread colour | Violet (high visibility), grooved |
| Thread length | 75 cm |
| Needle shape | 3/8 circle (approx. 135°) |
| Needle body and point | Triangular, reverse cutting point, grooved |
| Needle size | DS26 – 26 mm, 1 needle per suture |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, fascia closure, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
| Factory reference / SKU Cahnos | 412DS2630 / AM412DS2630 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis, with minimal tissue reaction |
This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained tension.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this technical data sheet (⅜ circle reverse cutting triangular needle of 26 mm, USP 3/0 gauge, 75 cm violet thread), commercial references from other manufacturers are cited below, cross-checked against primary sources (official catalogues and authorised distributors).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | PDS II® (polydioxanone) violet monofilament | Z968H (USP 3/0, 70 cm, violet, CP-2 26 mm reverse cutting needle) | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same USP 3/0 gauge, same violet colour, same reverse cutting point family and same needle size (26 mm). Differences: needle curvature and nomenclature (CP-2 vs DS26) and thread length (70 cm vs 75 cm). Confirmed in Ethicon’s official catalogue and authorised distributors. |
| B. Braun / Aesculap | MonoPlus® (polydioxanone) uncoated monofilament, violet | G2024520 (USP 3/0 / metric 2, 70 cm, violet, DS24 ⅜ circle body reverse cutting 24 mm needle) | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same USP 3/0 gauge, same violet colour and same ⅜ circle reverse cutting needle family. Differences: needle size (24 mm vs 26 mm DS26) and thread length (70 cm vs 75 cm). Confirmed in the official catalogue of B. Braun. |
There is no manufacturer-validated equivalence table that officially cross-references this reference with the commercial ranges of other brands; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: Ethicon’s PDS II® and PDS Plus® lines (the latter with an antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap, SMI’s Surgicryl® PDO line and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked against their official technical data sheet: USP gauge, thread length, colour, curvature, body, point and needle size. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and planes under tension. Needle shape is also decisive: the taper point (HR/DR) is the most atraumatic in delicate, well-perfused tissues, the trocar point (HRT/DRT) is reserved for firmer tissues and the reverse cutting triangular point (DS/HS) for fibrous tissues such as dermis and fascia.
| Reference Cahnos | Variant of interest |
| AMP412DS2630 | PDO/PDS Prime quality, same DS26 configuration, USP 3/0, violet, 75 cm (premium range) |
| AMP412DS2630.2 | PDO/PDS Prime, same DS26 26 mm needle, USP 3/0, violet, in double thread 2×75 cm (extended continuous sutures) |
| AM412DS2620 | PDO/PDS standard, same DS26 26 mm needle, USP 2/0, violet, 75 cm (larger gauge) |
| AMP412DS1930 | PDO/PDS Prime, DS19 19 mm needle, USP 3/0, violet, 75 cm (smaller access sites) |
| AMP412DS2430 | PDO/PDS Prime, DS24 24 mm needle, USP 3/0, violet, 75 cm (intermediate step) |
| AMP412DS3630 | PDO/PDS Prime, DS36 36 mm needle, USP 3/0, violet, 75 cm (longer needle path) |
All references are supplied in a box of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.