Absorbable Monofilament Polydioxanone Suture PDO/PDS Prime · Needle ½ Circle Cylindrical Conical Point Taperpoint HR17 (17 mm) · USP Size 0 · Violet Thread 75 cm · Box 12 units

46,34 €

Absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line, with a ½ circle cylindrical body needle with conical point (Taperpoint) of 17 mm (HR17), USP size 0 and violet fluted thread of 75 cm. Predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75 % at 2 weeks, 60–70 % at 4 and 45 % at 8. Sterilised by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Presentation in a box of 12 sterile units with B2B conditions for hospitals and purchasing centres. Ref. AMP412HR1710.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412HR1710

Description

1. Introduction

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line is the reference technical choice when prolonged tissue support is required with fully predictable resorption and minimal tissue reaction. This presentation combines a 75 cm violet thread in USP 0 gauge with a ½ circle needle, cylindrical body and conical point of 17 mm (HR17, Taperpoint), designed to pass through soft, well-perfused tissues with the least possible trauma. Available in a box of 12 units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with CE marking.

2. Technical Explanation

Polydioxanone is an absorbable synthetic polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillary edges, which reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knot-holding capacity make it ideal for ligatures and sutures of layers subjected to sustained tension.

The ½ circle needle (half-circumference curvature) with cylindrical body and conical point (Taperpoint) separates and glides through soft tissue with minimal injury, indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissue and ophthalmology. The USP 0 gauge (metric 3.5) offers high tensile strength; the grooved violet colour improves thread visibility on the surgical field.

3. Technical Specifications

3.1. General characteristics

Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Grooved monofilament
Quality Prime
Gauge USP 0 (metric 3.5)
Thread length 75 cm
Thread colour Violet (high visibility)
Needle shape ½ circle (half circumference)
Needle body and point Cylindrical, taperpoint conical point
Needle size HR17 – 17 mm
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units · SKU AMP412HR1710

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged strength-retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained tension. It is supplied sterile, ready for use, in individual packaging.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). Based on the verified configuration of this data sheet (½ circle cylindrical needle with conical point of 17 mm, USP 0 gauge, 75 cm violet thread), the following commercial reference from another manufacturer has been cross-checked in primary sources:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® (polydioxanone) violet monofilament, USP 0 gauge Z970H Comparable by category (not interchangeable 1:1) Same PDO monofilament material and same USP 0 gauge; confirmed in the GUDID/FDA regulatory database (ETHICON, LLC) and authorised distributors. Differences: CP-2 ½ circle needle with reverse cutting point of 26 mm versus the 17 mm HR17 taperpoint conical point of this reference, and thread length of 70 cm versus 75 cm.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon, the MonoPlus® line from B. Braun/Aesculap, the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked against their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and tension-bearing planes, as in this reference. The needle shape is also decisive: the conical point (HR) is indicated for delicate, well-perfused tissues (vessels, parenchyma), while the trocar point (HRT) is reserved for firmer tissues and the reverse cutting triangular point (HS) for fibrous tissues.

Within the Cahnos catalogue, the PDO/PDS family of ½ circle with conical point includes variants of interest: AM412HR2630 (HR26 needle of 26 mm, USP 3/0 gauge, 75 cm violet thread), AMP418HRP3020 (Ultra Plus HRP30 conical point, USP 2/0 gauge, 70 cm) and AMP413DR1750-2 (⅜ circle with double needle 2xDR17, USP 5/0 gauge, 90 cm). It also offers the trocar point version AMP418HRT1720 (HRT17, USP 2/0, 70 cm) and the reverse cutting triangular AMP412HS3620 (HS36, USP 2/0, 75 cm). Always verify the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic absorbable monofilament

Gauge

USP 0 (metric 3.5)

Tip type

Cylindrical body, conical point (Taperpoint)

Needle size

HR17 – 17 mm

Sterilisation

Ethylene oxide, single-use

Presentation

Box of 12 sterile units

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular surgery and ophthalmology

Reference

AMP412HR1710

Medida de aguja

HR 17

Usp

0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)