Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture offered by Cahnos, reference AM415HRN50L01, is the reference solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and purchasing centres looking for a long-lasting absorbable synthetic suture with a very competitive price-quality ratio.
This presentation combines a ½ circle cylindrical body needle with a 50 mm blunt point, USP 1 gauge (metric 4) and 150 cm violet thread mounted in a loop, ideal for continuous sutures and planes with sustained tension. It is supplied sterile and ready to use, in a box of 12 units.
2. Technical Explanation
Polydioxanone is an absorbable synthetic polyester (poly(p-dioxanone) polymer) that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity, ensuring very reproducible absorption kinetics among individuals. Being a monofilament, the thread has no wick effect or capillary edges: it reduces bacterial adherence, minimises tissue sawing and facilitates sliding through tissue, with a firm feel and excellent knot-tying security.
The ½ circle needle with cylindrical body and blunt point (HRN) passes through tissue by separating the fibres rather than cutting them: it is the natural choice for delicate, friable or highly vascularised tissues (vessels, thin intestinal walls, paediatric cardiovascular tissue and the ophthalmological field), reducing the risk of tearing and bleeding at the entry point. USP 1 gauge (metric 4) provides high initial strength for planes subjected to moderate-high tension. The 150 cm loop format allows placement of the first stitch and anchoring of the continuous suture without rethreading, a clinically relevant advantage in laparoscopy and restricted fields. The violet colour ensures optimal visibility throughout the procedure. Sterile single-use product, not to be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone) |
| Quality / range | Normal |
| Gauge / size | USP 1 (metric 4) |
| Thread colour | Violet (high visibility) |
| Thread length | 150 cm in loop format |
| Needle shape | ½ circle (half circumference), cylindrical body |
| Tip type | Blunt point (HRN) |
| Needle size | HRN 50 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 180-210 days |
| Sterilisation | Ethylene oxide (EO), single-use, not for re-sterilisation |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 units |
| Reference / SKU | AM415HRN50L01 |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
| Complete absorption | 180-210 days by hydrolysis |
This prolonged force retention profile is maintained during the critical healing phase of slow-recovery tissues, therefore its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained traction.
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). For the configuration of this data sheet (½ circle cylindrical blunt point HRN needle 50 mm, USP 1 gauge, 150 cm violet thread in loop) the following commercial references have been cross-checked against primary sources (official Ethicon EMEA catalogue and GUDID/FDA regulatory database, via verified internal technical records):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone), CTX conical needle ½ circle 48 mm, loop 150 cm, violet, USP 0 | Z990G | Comparable by category (not interchangeable 1:1) | Same material (violet PDO monofilament), same ½ circle needle family and same 150 cm loop format. They differ in gauge (USP 0 vs USP 1), point type (conical vs blunt) and needle size (CTX 48 mm vs HRN 50 mm). Verified in GUDID; confirm batch and regulatory classification before substituting. |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone) with tapercut V-40 ½ circle needle, violet, USP 1 | Z1930G | Comparable by category (not interchangeable 1:1) | Same material (violet PDO monofilament) and same USP 1 gauge. They differ in point type (tapercut vs blunt) and thread length (180 cm vs 150 cm). Confirmed in official Ethicon EMEA catalogue; verify needle and CE marking before substituting. |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone) with V-37 needle, 150 cm loop, violet, USP 0 | Z1932E | Comparable by category (not interchangeable 1:1) | Same material base (violet PDO monofilament) and same 150 cm loop format. They differ in gauge (USP 0 vs USP 1) and needle (V-37 vs blunt HRN 50 mm). Reference located in catalogues of authorised distributors; cross-check complete configuration in the manufacturer’s official data sheet. |
As homologous market lines to be verified code by code before substitution: the PDS Plus line from Ethicon (same PDO base with triclosan antibacterial coating, references of the type PDP9261G/PDP9261T in USP 0 gauge, only where its use is approved), the MonoPlus line from B. Braun/Aesculap, the Surgicryl PDO line from SMI, the Maxon line from Medtronic/Covidien and DemeDIOX from DemeTech. All must be checked in their official technical data sheet (gauge, needle geometry and size, thread length and format, colour and CE/MDR regulatory classification).
There is no equivalence table validated by the manufacturer for cross-brand use in the exact configuration of blunt point HRN needle 50 mm with 150 cm loop and USP 1 gauge; consult with the technical department before using in tenders. The brands cited belong to their respective manufacturers and are mentioned only for comparative reference.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for planes with moderate-high tension: fascia, aponeurosis, abdominal wall and ligatures of medium-calibre vessels. The ½ circle blunt point needle offers the most atraumatic passage of the entire PDO/PDS family; if the tissue is firm and more penetration power is needed, consider the conical point variant (Taperpoint) or Ultra Plus conical trocar from the same range. The 150 cm loop format facilitates long continuous sutures and multiple ligatures without rethreading.
Within the Cahnos catalogue, the following variants of the same PDO/PDS family are available:
| Reference | Variant of interest |
|---|---|
| AMP415HRN50L01 | PDO Prime, same HRN needle with blunt point 50 mm, 150 cm violet loop, USP size 1 (same configuration with Prime finish) |
| AM415HRN50L10 | PDO standard quality, same HRN needle with blunt point 50 mm, 150 cm violet loop, USP size 0 (next lower size) |
| AMP415HRN50L10 | PDO Prime, same HRN needle with blunt point 50 mm, 150 cm violet loop, USP size 0 |
| AM415HR50L01 | PDO standard, conical HR needle 50 mm, USP 1, 150 cm violet loop (conical point instead of blunt) |
| AM415HR40L01 | PDO standard, conical HR40 needle 40 mm, USP 1, 150 cm violet loop (shorter needle) |
| AM415HR65L01 | PDO standard, conical HR65 needle 65 mm, USP 1, 150 cm violet loop (larger radius for deep planes and fascia) |
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or validation of equivalences from other commercial brands, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.