PDO - 1-2 Circle Cylindrical Body Blunt Point
The category of PDO suture 1/2 circle blunt point brings together absorbable monofilament sutures made of polydioxanone (PDO/PDS) with a half-circle needle and cylindrical body, a combination especially valued in the operating theatre for its atraumatic passage through delicate tissues and its predictable absorption profile. These are synthetic sutures designed for the approximation of tissue planes and the placement of ligatures in procedures where reliable tensile support is needed for several weeks, with progressive reabsorption that avoids a second intervention to remove stitches. In this family, the professional buyer finds references with violet thread of 90 cm and 150 cm, in USP 0 and USP 1 gauges, with or without loop, and high-quality Prime versions, allowing the choice to be adjusted to the type of surgery, tissue thickness and the surgical team’s knotting technique.Main applications and variety:General and digestive surgery: wall closure, anastomoses and ligatures where the blunt-point needle reduces the risk of inadvertent puncture in friable tissues.Cardiovascular and paediatric surgery: vascular anastomoses and precision procedures that benefit from the prolonged absorption profile of PDO.Ophthalmology and delicate tissue surgery: fine sutures with a half-circle cylindrical needle for controlled and atraumatic handling.Presentation variety: options with 90 cm or 150 cm thread, in USP 0 and USP 1 gauges, with violet grooved loop or without loop, and Prime line for centres that prioritise uniformity of clinical performance.
Products
Showing all 6 results
-

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · ½ Circle Cylindrical Body Blunt Point HRN 50 mm Needle · USP Size 0 · Violet Thread 150 cm with Loop · Box of 12 units (Ref. P415HRN50L10)
51,86 € In stockAdd to basket -

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · ½ Circle Cylindrical Body Needle Blunt Point 45 mm (HRN45) · USP Gauge 1 · Violet Thread 90 cm · Ref. AMP413HRN4501 · Box of 12 units
51,86 € In stockAdd to basket -

Absorbable Monofilament Polydioxanone PDO/PDS Suture Type PDS · Needle ½ Circle Cylindrical Body Blunt Point HRN 50 mm · USP Gauge 0 · Violet Thread 150 cm with Loop · Box of 12 Units (Ref. 415HRN50L10)
38,56 € In stockAdd to basket -

Absorbable Monofilament Polydioxanone Suture (PDO/PDS) · ½ Circle Cylindrical Blunt Point Needle HRN 50 mm · USP Size 1 · Violet Thread 150 cm with Loop · Box of 12 units · Ref. AM415HRN50L01
38,56 € In stockAdd to basket -

Absorbable Monofilament Polydioxanone Suture PDO/PDS · Needle ½ Circle Cylindrical Body Blunt Point 45 mm (HRN45) · USP Gauge 1 · Violet Thread 90 cm · Ref. AM413HRN4501 · Box 12 units
38,56 € In stockAdd to basket -

Absorbable Monofilament Suture PDO/PDS Prime · Needle ½ Circle Cylindrical Blunt Point HRN (50 mm) · USP Gauge 1 · Violet Thread 150 cm with Loop · Box of 12 units
51,86 € In stockAdd to basket
To select the most suitable PDO suture 1/2 circle blunt point, it is advisable to consider together the USP gauge, thread length, presence or absence of a loop and the product line. The gauge defines tensile strength and must align with the thickness of the tissue to be sutured; the thread length (90 cm or 150 cm) conditions the number of passes and the autonomy per suture, especially relevant in long procedures or those with multiple anastomoses. The loop version facilitates passage through tubular structures and continuous knotting, while the presentation without a loop offers greater control in interrupted stitches. The Prime line provides manufacturing homogeneity aimed at centres with high surgical volumes. Comparing these criteria with the surgical technique and the team's preference allows inventory to be optimised and costs per procedure to be reduced without compromising clinical safety.
Our commercial team is at your disposal to advise you on choosing the most suitable reference according to the specialty, consumption volume and supply agreements of your centre. We manage recurring orders, warehouse batches and technical queries about equivalences between Prime and standard lines. If you need guidance to configure a volume order or resolve doubts about gauges, lengths or loop presentations, contact us and we will offer you a personalised response as soon as possible.