Description
1. Commercial Introduction
The portable digital spirometer SP-10 (manufacturer reference 33536, SKU Cahnos GM33536) is the pocket solution for assessing lung function in pulmonology clinics, primary care, occupational health services, mutual insurance companies and home monitoring under professional supervision. Its compact design and large TFT screen allow direct and reliable readings of the main spirometric parameters anywhere, without depending on a computer. It includes a rechargeable lithium battery, USB cable, charger and analysis software, making it a complete, self-contained unit ready to work from the outset.
2. Technical explanation of the equipment
The SP-10 performs spirometry by synchronised measurement of the main flow and volume indices of a forced expiration: Forced Vital Capacity (FVC), Peak Expiratory Flow (PEF), Forced Expiratory Volume in the first second (FEV1), FEV1/FVC ratio (FEV1%) and the forced expiratory flows FEF25, FEF25-75 and FEF75. The device displays the flow-volume and volume-time curves on screen, providing graphical evidence to support the diagnosis and therapeutic evaluation of respiratory diseases.
It incorporates integrated predicted values, battery level indicator and free PHMS app for data storage and management. The included PC software allows results to be calculated and patient evolution trends to be analysed over time, facilitating screening and follow-up.
3. Technical Specifications
Product data:
| Manufacturer | GIMA |
|---|---|
| Model | SP-10 (pocket spirometer) |
| Manufacturer reference | 33536 |
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | II A |
| CND | Z12150199 |
| EAN | 6945040100355 |
Technical specifications:
| Parameter | Value |
|---|---|
| Maximum volume | 10 l |
| Volume precision | ±3 % or 50 ml (whichever is greater) |
| Flow range | 1 l/s – 16 l/s |
| Flow precision | ±10 % or 0.3 l/s (whichever is greater) |
| Parameters | FVC, FEV1, PEF, FEV1%, FEF25, FEF25-75, FEF75 |
| Display | Large TFT (numerical values and flow-volume / volume-time curves) |
| Power supply | Internal rechargeable lithium battery with charge level indicator |
| Connectivity | USB cable for PC connection and charging |
| Regulatory standard | CE 92/42 – EMC group I class B – type BF protection |
Included accessories
| Component | Description |
|---|---|
| Battery | Internal rechargeable lithium battery |
| USB cable | PC connection |
| PC software | Data calculation and trend analysis |
| User manual | Available in GB, FR, IT, ES, PT, SE, LT, SK, HU and RO |
4. Equivalences and Cross-References
This device corresponds to the manufacturer’s original reference . 33536, marketed at Cahnos under the SKU GM33536 (CND Z12150199, EAN 6945040100355). There is no manufacturer-validated equivalence table allowing references from other brands to be declared as 1:1 interchangeable with the SP-10: the measurement sensor, electronics and management software are specific to each platform, so any substitution between manufacturers must always be validated field by field (volume/flow range and precision, power supply, connectivity and accessories) with the technical department before use in tenders.
Within the spirometry catalogue, the SP-10 is complemented by the following consumables and spare parts from the same family: antibacterial filters SPIROGUARD (ref. 33557), disposable nasal forceps (refs. 33475/33476), disposable mouthpieces, the turbine replacement kit with reusable mouthpiece (ref. 33900) and the 600D polyester carrying bag (ref. 27139).
5. Selection tips and variants of interest
Test scope: the SP-10 is a pocket spirometer indicated for measuring FVC, FEV1, FEV1%, PEF and forced expiratory flows (FEF25, FEF25-75, FEF75) with curve display on TFT screen and data management via PHMS app and PC software. It is the most compact option in the range; for a handheld device with turbine sensor and expanded memory (224 cases with graph), consider the SP-80B (ref. 33551), and for complete professional testing with touchscreen and integrated thermal printer, the SP-100B (ref. 33554). If you only need to measure FEV1 and PEF with smartphone management, also see the solutions from the SMART ONE (refs. 33681 and 33684) family.
Hygiene protocol: use a disposable mouthpiece per patient and consider the use of SPIROGUARD antibacterial filters (ref. 33557) and nasal forceps (refs. 33475/33476) to optimise the quality of the manoeuvre and minimise the risk of cross-contamination, following the recommendations of the ERS and SEPAR societies.
For large orders you can request a quote: contact our technical-commercial team to formalise the order, supply conditions and advice on compatible accessories.