Description
1. Commercial Introduction
The paediatric cardboard mouthpiece 22×60 mm (ref. 01558) is the essential single-use consumable for lung function tests in paediatric patients. Its compatibility covers Cosmed spirometers in paediatric version (Pony paediatric model), Clement Clarke, Vitalograph and Micro Medical co-oximeters from the Micro-CO and Smoke Check series, making it the ideal replacement solution for respiratory medicine, allergology, paediatrics, primary care and occupational medicine units with a high turnover of tests.
Each mouthpiece is supplied individually packed in a unit bag and the commercial presentation is a box of 100 units, ensuring that each patient always has a new and hygienic adapter for each manoeuvre. Available with immediate stock for direct dispatch.
2. Technical explanation of the procedure
During spirometry, the patient breathes forcefully through the mouthpiece connected to the transducer or turbine of the spirometer, and the device records parameters such as forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), peak expiratory flow (PEF) or forced flow at 25-75% of expiration (FEF25-75%). For the diagnosis to be reliable, the flow must pass through a conduit of constant calibre and without leaks: any slack or deformation alters the reading. In paediatric patients, the smaller outer diameter (22 mm) fits the specific coupling of infant equipment and facilitates the lip-sealing manoeuvre in small mouths.
In co-oximetry (Micro-CO, Smoke Check), the mouthpiece connects the patient’s exhalation to the electrochemical sensor that measures carbon monoxide in exhaled air, so it must also ensure a firm seal and a stable flow.
A single-use cardboard mouthpiece offers three key advantages:
- Hygiene: prevents cross-contamination between patients, with no need for reprocessing or sterilisation.
- Accuracy: stable calibre and firm fit to the equipment adapter, with low flow resistance.
- Economy: minimal cost per test, ideal for continuous use in paediatrics and screening campaigns.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Dimensions | 22 × 60 mm (outer diameter × length; extension/long format) |
| Outer diameter | 22 mm |
| Inner diameter | 20 mm (standard construction for the 22 mm calibre in paediatric mouthpieces) |
| Material | Disposable medical-grade cardboard, single-use (spiral, non-toxic adhesive, satin finish) |
| Compatibility | Cosmed (Pony paediatric), Clement Clarke (paediatric), Vitalograph (paediatric) and Micro Medical co-oximeters (Micro-CO, Smoke Check) |
| Presentation | Unit packaging in bag |
| Units per box | 100 units |
| Use | Single-use (disposable) |
| Indication | Paediatric spirometry and lung function tests; co-oximetry (measurement of CO in exhaled air) |
| Reference / SKU | 01558 |
Refer to the labelling and the declaration of conformity of the batch for the regulatory requirements required in your tender. Within the same family of disposable spirometry mouthpieces, the range is completed with the following variants:
| Reference | Measurements | Compatibility |
|---|---|---|
| 01551 | 26 ext. × 73 mm | Fukuda, Jaeger, Welch-Allyn |
| 01552 | 27 ext. × 70 mm | Poch-Millas, Minato (Autospiro AS500), Cicatest, Eymasa (Neumos-12) |
| 01553 | 30.5 ext. × 60 mm | Cosmed (Pony), Vitalograph, Trentina (Pneumos) |
| 01554 | 30 ext. × 60 mm | Datospir Peak 10, Clement Clarke, Takio, Micromedical (Microlab), Multispiro, MIR (Spirolab, Spirobank), Bosh-501, Mini-Bell |
| 01555 | 28 ext. × 60 mm | Datospir (Sibelmed) |
| 01557 | 21 ext. × 70 mm | Datospir paediatric, Poch-Millas paediatric |
| 01558 | 22 ext. × 60 mm | Cosmed paediatric, Clement Clarke paediatric, Vitalograph paediatric, Micro Medical co-oximeter (Micro-CO, Smoke Check) |
4. Equivalences and Cross-References
Cardboard mouthpieces for spirometry are a generic market consumable; compatibility verification must always be carried out by measurements (outer diameter and length) and by the equipment adapter. References from other manufacturers and authorised suppliers have been identified with the same compatibility family and the same dimensions (60 mm long × 20 mm inner Ø × 22 mm outer Ø):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Lessa (AB Medica group) | Single-use PEDIATRIC mouthpiece (Micro Medical) and PONY PEDIATRIC (Cosmed) | 9983722 | Comparable by category (not interchangeable 1:1) | White satin spiral cardboard with non-toxic adhesive; length 60 mm × inner Ø 20 mm × outer Ø 22 mm: same dimensions as reference 01558. Code verified in the official Lessa catalogue. |
| GIMA (Italy) | Single-use paediatric paper mouthpieces (250 units) | 33411 (EAN 8023279334111) | Comparable by category (not interchangeable 1:1) | Paper/cardboard; inner Ø 20 × outer Ø 22 × 60 mm; compatible with Micromedical, Vitalograph and MIR; CE class IIa, manufactured in Europe; individually packed. Code verified in the official technical data sheet of GIMA. |
| Vitalograph | SafeTway Mouthpiece Pediatric, disposable cardboard | 20980 | Comparable by category (not interchangeable 1:1) | Disposable cardboard with outer Ø 22 mm, pack of 50 units, with SafeTway one-way valve for flow meters and spirometers; valve design, not 1:1 interchangeable with a simple mouthpiece. Code verified at authorised distributors of the manufacturer. |
There is no equivalence table validated by the manufacturer that cross-references this generic reference with codes from other brands on a 1:1 interchangeable basis; consult the technical department before using in a tender. Other lines in the sector (e.g. Modul USA, ref. MP003-2022-50, paediatric mouthpiece inner Ø 20 / outer Ø 22 mm for Cosmed) offer single-use mouthpieces of similar dimensions; always verify outer diameter, length and fit to the adapter before replacing reference 01558.
5. Selection tips and variants of interest
- Confirm the adapter measurements: before replacing the mouthpiece, verify the outer diameter and length that the head of your spirometer accepts; a short or larger-diameter mouthpiece can alter the flow circuit and the calibration of the device.
- Paediatric population: this 22×60 mm reference is the ideal one for Cosmed (Pony paediatric), Clement Clarke, Vitalograph and Micro Medical co-oximeters. For paediatric Datospir and Poch-Millas, the 21×70 mm paediatric mouthpiece (ref. 01557) is available.
- Bulk format: if your centre prefers bulk packaging to reduce cost per test, the same 22×60 mm paediatric mouthpiece is available in a bag of 100 units under reference WETE602220.
- Recommended accessories: complete the manoeuvre with a disposable nasal clip and, in maximum protection studies, combine with a compatible bacterial/viral filter (refs. 08268/08269) for a complete and safe spirometry.
Equip your paediatric practice or your respiratory medicine department with reliable consumables: we have immediate stock for direct dispatch.