Antibacterial filter with integrated mouthpiece for Customed and Jaeger spirometers – Box of 100 units (Ref. 33886)

234,65 €

Disposable antibacterial filter with integrated mouthpiece, anatomical in shape, designed to prevent bacterial and viral contamination in spirometry tests. It connects directly to the spirometer on one side and to the patient on the other, with no need for an additional mouthpiece. Compatible with spirometers from the brands Customed and Jaeger (inner Ø 2.95 cm × outer Ø 3.3 cm). Class II A medical device, individually packaged in a transparent bag and manufactured in Italy. Presentation in a box of 100 units. Reference 33886 (SKU GM33886).

Sales unit: caja de 100
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33886

Description

1. Commercial Introduction

Ensure maximum hygiene in your spirometry tests with this single-use antibacterial filter with integrated mouthpiece, specially developed for spirometers from the brands Customed and Jaeger. It is a reference consumable in pulmonology clinics, primary care, occupational medicine and pulmonary function laboratories, where the rotation of tests demands a reliable hygienic barrier between patient and equipment.

Its anatomical design with integrated mouthpiece facilitates the patient’s breathing manoeuvre and eliminates the need for additional mouthpieces, optimising the cost per test. Each unit is supplied individually packaged in a transparent bag and the commercial presentation is a box of 100 units, the most cost-effective format for centres with high clinical activity.

2. Technical Explanation

During spirometry, the patient performs forced breathing manoeuvres through the spirometer circuit. The European scientific societies (ERS) and SEPAR recommend performing all pulmonary function tests with a disposable bacterial and viral filter to prevent the spread of aerosols, reduce the risk of cross-infection between patients and protect the circuit and the equipment’s electronics.

This filter acts as a barrier against bacteria and viruses thanks to its filter medium, maintaining low flow resistance and reduced dead space so as not to distort flow and volume measurements. It is very easy to use: on one side it connects directly to the spirometer and on the other it serves as the mouthpiece for the patient. As a single-use consumable, it simply needs to be replaced for each patient to maintain an impeccable hygiene protocol, with no need for reprocessing or disinfection of the circuit.

3. Technical Specifications

Inner measurement Ø 2.95 cm
Outer measurement Ø 3.3 cm (end to end)
Filter type Disposable antibacterial and antiviral, with integrated mouthpiece
Shape Anatomical
Use Single-use, for one patient
Compatibility Customed, Jaeger
Packaging Each unit in individual transparent bag
Instructions Multilingual: GB, FR, IT, ES, PT, DE, NL, DK, SE, FI, LT, LV, EE, PL, CZ, SK, HU, SI, HR, RO, BG, GR
Manufacture Italy

Product data

Manufacturer GIMA
Sales unit Box of 100 units
Device type Medical device
Device class II A
CND R049001
EAN 8023279338867

4. Equivalences and Cross-References

This product corresponds to the manufacturer’s original reference Ref. 33886, a filter with integrated mouthpiece for Customed and Jaeger spirometers. There is no manufacturer-validated equivalence table that would allow references from other brands to be declared as 1:1 interchangeable with this filter. In the sector, other companies such as Vyaire/CareFusion (MicroGard™ range) or Intersurgical (Pulmo-Protect™ range) offer comparable high-efficiency spirometry filters by category, but compatibility always depends on the equipment’s connection size; check the connection diameter of your spirometer before replacing this filter.

For equipment of other brands, see the filters in the same family in our catalogue: version for Mir, Micromedical, Vitalograph, Ferraris and Cardiette (GM33884), version for Cosmed (GM33885) and version for BTL and Sibel (GM33902).

5. Selection tips and variants of interest

Check the connection size of your spirometer: this filter (inner Ø 2.95 cm × outer Ø 3.3 cm) is the specific version for Customed and Jaeger equipment. If your equipment is from another brand, select the appropriate reference from the family (GM33884 for Mir, Micromedical, Vitalograph, Ferraris and Cardiette; GM33885 for Cosmed; GM33902 for BTL and Sibel).

Replacement per patient: as a single-use consumable packaged individually, change it at each spirometry test and keep stock by box of 100 units so as not to interrupt clinical activity. Combine the filter with a disposable nose clip and, if you carry out periodic checks, validate the equipment with the corresponding calibration syringe. For volume orders, supply contracts or tenders, contact our technical-commercial team at Cahnos, who will prepare a budget tailored to your needs.

Additional information

Manufacturer reference

33886

Product type

Disposable antibacterial and antiviral filter with integrated mouthpiece

Measurements

Inner Ø 2.95 cm × Outer Ø 3.3 cm

Shape

Anatomical

Compatibility

Customed, Jaeger

Use

Single-use, one patient

Presentation

Box of 100 units

Packaging

Individual, in transparent bag

CND code

R049001

EAN

8023279338867

Presentacion

Box of 100

Tipo dispositivo

Medical device

Clase sanitaria

II a

Pais fabricacion

Italy

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityItaliano PDF
📜 CE certificateDownload PDF