Description
Reliable protection for your pulmonary function tests
This 34.5 mm disposable bacterial/viral filter is the reference consumable to ensure maximum hygiene in spirometry and pulmonary function diagnostic tests. Designed to be installed in-line between the patient and the equipment, it acts as a barrier against bacteria and viruses and prevents cross-contamination between patients, also protecting the professional and the spirometer electronics. Its integrated mouthpiece, with an ergonomic oval design, eliminates the need for an additional mouthpiece and reduces the cost per test, while maintaining accurate and repeatable results even in high hospital workloads.
How does it work and why is it essential?
The European Respiratory Society (ERS) and SEPAR recommend that all pulmonary function tests be performed with a disposable bacterial and viral filter to prevent the dissemination of aerosols and the risk of contagion between patient and technician. This filter combines an electrostatic and mechanical filtration method on a 3M™ membrane that retains particles, bacteria and viruses while maintaining a very low flow resistance (0.7 cm H2O/l/s at 12 l/s) and a dead space of less than 75 ml, so it does not distort flow, volume and vital capacity measurements under BTPS conditions. As it is a single-use consumable individually packaged, simply replace it for each patient to maintain an impeccable hygienic protocol without the need for circuit disinfection.
Technical specifications
| Characteristic | Value |
| Diameter | 34.5 mm |
| Bacterial filtration efficiency | 99.999990 % |
| Viral filtration efficiency | 99.9981 % |
| Flow resistance | 0.7 cm H2O/l/s at 12 l/s |
| Dead space | < 75 ml |
| Filtration method | Electrostatic and mechanical |
| Membrane material | 3M™ |
| Weight | 40 g |
| Mouthpiece | Integrated, ergonomic oval design; no additional mouthpiece required |
| Target population | Adult and paediatric |
| Use | Disposable, single-use |
| Packaging | Individual, sealed against external factors |
| Presentation | Box of 100 units |
| Regulatory classification | Medical device Class IIa (Directive 93/42/EEC; Regulation (EU) 2017/745) |
Compatibility
| Spirometer brand | Field of application |
| CareFusion | MasterScreen, Vmax equipment and pulmonary function systems with 34.5 mm connection |
| Jaeger | MasterScreen, Micro I./SpiroUSB, MicroLab, MicroLoop and Jaeger family equipment |
| SensorMedics | Vmax, Graphic Series G70M, series 2200/2400/2450/2800/6200 and related systems |
| Viasys | Brand pulmonary function platforms and analysers |
Note: compatibility depends on the equipment connection size (34.5 mm for this filter). Always check the connection diameter of your spirometer before placing the order.
Equivalences and cross-references
The 34.5 mm diameter with integrated mouthpiece is the standard size for pulmonary function platforms of the Jaeger/CareFusion family (MasterScreen, Vmax, Vyntus), SensorMedics and Viasys. The following commercial references in the sector have been cross-checked, all verified in official manufacturer or authorised distributor catalogues:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Sibelmed | Bacterial/viral spirometry filter 34.5 mm | 09700 (box of 100) | Comparable by category (not interchangeable 1:1) | Specifications matching the product data sheet (bacterial efficiency 99.999990% and viral efficiency 99.9981%, size 34.5 mm and compatibilities VIASYS, SENSORMEDICS and JAEGER). Confirmed on the manufacturer’s website. |
| Vyaire / Jaeger Respiratory Diagnostics | MicroGard™ II C (round filter) | V-892384 (box of 50) | Comparable by category (not interchangeable 1:1) | Single-use filter with round connector for Jaeger/Vyaire (Vyntus, MicroLab, MicroLoop…); bacterial and viral efficiency of 99.999%; presentation in box of 50 units |
| A-M Systems | VBMax™ PFT Filter 34 mm | 146700 (box of 100) | Comparable by category (not interchangeable 1:1) | For Jaeger, MasterScreen, Vmax Vyntus and Vyaire; integrated oval mouthpiece; dead space 45 ml; resistance < 1.5 cm H2O/l/s; CE marking and FDA authorisation |
| Intersurgical | Pulmo-Protect™ (spirometry filter) | 1691000 (box of 50) | Comparable by category (not interchangeable 1:1) | Filtration efficacy > 99.99% against viruses and bacteria; compatible with JAEGER, MasterScreen, SensorMedics, Vmax, Micro Medical, Chest and MicroGard; presentation in box of 50 |
There is no manufacturer-validated equivalence table that allows these references to be declared as interchangeable 1:1; consult the technical department before using in tenders.
Selection tips and variants of interest
- Check the connection size: this filter is 34.5 mm (integrated mouthpiece). For Datospir-Sibelmed equipment, select the 28 mm filter (ref. 08268) and for NSPIRE, MIR, Vitalograph, Micromedical, Cosmed and Clement Clarke, the 30 mm one (ref. 08269).
- Replacement per patient: as it is a single-use consumable, change it after each spirometry and keep stock by box of 100 units to avoid interrupting clinical activity.
- Complete the test kit: combine the filter with disposable nasal forceps and compatible mouthpieces for a complete hygienic protocol.
- Calibration: if you perform periodic checks, remember to validate the equipment with the 3-litre calibration syringe (ref. 08290) to maintain the certified accuracy of ±0.5%.
- For high-volume pulmonary function laboratories working with Jaeger/CareFusion or Vyaire platforms, this 34.5 mm filter is the recommended replacement for cost per test compared to kits with individual mouthpiece and forceps.