Disposable Datospir Touch (Sibelmed) transducer kit: handle, bag and 25 Lilly transducers | Ref. 07046

290,00 €

Disposable transducer kit for the Datospir Touch (Sibelmed) spirometer, reference 07046: includes handle, transducer bag and 25 disposable Lilly transducers per kit. Single-use hygienic spirometry solution: eliminates disinfection between patients, reduces the risk of cross-contamination and requires no pre-calibration. Compatible with the disposable Easy-D and Diagnostic-D configurations of the Datospir Touch, with a measurement range of 0 to ±16 l/s (BTPS). Sold per unit (1 kit); ideal for primary care, occupational medicine and lung function units.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
07046

Description

1. Introduction

The disposable transducer kit for Datospir Touch is the replacement that keeps your Sibelmed desktop spirometer operational in disposable (Lilly) configuration, the most hygienic and lowest workload option in the range. In a single purchase you receive the handle, transducer bag and 25 disposable transducers, ready to replace the measurement circuit of the equipment without waiting or reprocessing: each patient has their own single-use transducer, which eliminates disinfection between tests and minimises the risk of cross-contamination between patient and technician.

2. Technical explanation of the equipment and procedure

The disposable transducer included in this kit is a differential pressure Lilly-type pneumotachograph: the air exhaled by the patient passes through a pneumatic resistance with a known flow pattern and the equipment calculates the flow from the pressure difference generated between its ends. Its controlled manufacturing design means the transducer does not require pre-calibration, maintaining the measurement accuracy characteristic of the Datospir Touch.

The transducer attaches to the spirometer via the handle and transducer bag included in the kit. The patient blows through the disposable transducer (or an additional bacterial/viral filter), and the equipment records the flow-volume and volume-time curves, calculating more than 40 spirometric parameters (FVC, FEV1, PEF, FEF25-75 %, etc.) with manoeuvre quality control. In accordance with the recommendations of the ERS and SEPAR societies, lung function tests should be performed with a disposable bacterial and viral filter between patient and sensor; the disposable transducer is already discarded after each patient, and if your protocol requires it, you can also insert a bacterial/viral filter (ref. 09698) without degrading the measurements.

3. Technical Specifications

Reference / SKU 07046
Product type Handle + disposable transducer bag kit for Datospir Touch spirometer
Kit contents 25 disposable Lilly-type transducers + handle + transducer bag
Compatibility Datospir Touch Spirometer (Sibelmed) in disposable Easy-D / Diagnostic-D configurations
Measurement technology Disposable Lilly-type pneumotachograph (differential pressure), no pre-calibration
Measurement range (BTPS) – Flow 0 to ±16 l/s
Measurement range (BTPS) – Volume 0 to 10 l
Dynamic resistance at 14 l/s (disposable) <1.2 cmH₂O/l/s
Accuracy (BTPS) – Volume ±2.5 % or 50 ml (whichever is greater)
Accuracy (BTPS) – Flow ±3 % or 150 ml/s (whichever is greater)
Accuracy – PEF ±10 % or 170 ml/s
Temporal precision / Volume resolution 0.50 % / <10 ml
Sampling frequency 100 Hz
Use Single-use; suitable for adult and paediatric patients
Transducer module (manufacturer) 09889 (Datospir Touch disposable transducer module)
Sales unit Per unit (1 kit of 25 transducers)

Measurement specifications of the Datospir Touch system in disposable configuration according to the official technical data sheet of Sibelmed (SIBEL S.A.U.).

4. Equivalences and Cross-References

The 07046 kit corresponds to the disposable circuit of the Sibelmed Datospir Touch spirometer: the handle, transducer bag and connection electronics are specific to this equipment, so there is no interchangeable 1:1 substitute from another brand that fits the same spirometer. Within the Sibelmed family, the disposable module corresponds to the official code 09889 (in the same range as the Fleisch 09888 and the turbine 09890); as alternative consumables from the same manufacturer, the disposable transducer without filter (ref. 03169, bag of 50 units), the disposable transducer with integrated filter (ref. 09718) and the handle + bag kit in 50-unit format for the Datospir 120, 110 and 600 models (ref. 02269) are offered.

The following disposable sensors from other manufacturers have been verified, comparable only at the functional category level (spirometry with single-use sensor), never interchangeable with the Datospir Touch circuit:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
MIR (Medical International Research) FlowMIR® disposable turbine with mouthpiece (Spirobank II, Spirolab, Spirodoc, Minispir) 910004 Comparable by category (not interchangeable 1:1) Factory-calibrated disposable turbine sensor individually packaged (box of 60 units); same single-use spirit without recalibration or reprocessing, but coupling, electronics and measurement principle (turbine/impeller) specific to MIR equipment. Code and attributes verified in official technical data sheet of MIR.
COSMED T2 bidirectional turbine (Pony FX, microQuark, Spiropalm) C02235-01-05 Comparable by category (not interchangeable 1:1) 28 mm bidirectional turbine flowmeter for COSMED spirometers; measurement principle by impeller, but it is a reusable (not disposable) component with its own connector and electronics. Code verified in official COSMED store; does not replace the disposable circuit of the Datospir Touch.

There is no equivalence table validated by the manufacturer that cross-references this reference with codes from other brands in an interchangeable 1:1 manner; consult with the technical department before using in a tender. Other brands in the sector with single-use sensors in the same functional category are Vitalograph and nSpire; in all cases verify the coupling to the handle, the equipment electronics and the consumables before any substitution.

5. Selection tips and variants of interest

Choose the transducer according to your centre’s profile: the disposable Lilly transducer in this kit is the option offering maximum hygiene and the lowest operational workload, recommended for primary care, occupational medicine and screening campaigns, since each patient’s transducer is discarded and no disinfection is required. If your lung function unit requires the maximum precision of the differential pressure pneumotachograph, the Datospir Touch range also supports the Fleisch kit (ref. 07052) and, for lower running costs, the turbine kit (ref. 07053/09890).

Remember to replace the bacterial/viral filter for each patient (refs. 09698 or 08268) and to have compatible cardboard mouthpieces of 28×60 mm (ref. 01555) and a nasal clip (refs. 02692 or 09661). For transducer quality control, use the 3-litre calibration syringe (ref. 08290) in accordance with ATS/ERS recommendations, and for paediatric patients attach the paediatric mouthpiece adapter (ref. 01149). Confirm the configuration of your Datospir Touch (Easy-D or Diagnostic-D) before purchase to ensure the correct spare part and, for special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.

Additional information

Reference

07046

Product type

Handle + disposable transducer bag kit for Datospir Touch spirometer

Contents

25 disposable Lilly-type transducers + handle + transducer bag

Compatibility

Datospir Touch Spirometer (Sibelmed), Easy-D / Diagnostic-D configurations

Measurement technology

Disposable Lilly-type pneumotachograph (differential pressure), no pre-calibration

BTPS flow range

0 to ±16 l/s

BTPS volume range

0 to 10 l

Volume accuracy

±2.5 % or 50 ml (whichever is greater)

Flow accuracy

±3 % or 150 ml/s (whichever is greater)

PEF accuracy

±10 % or 170 ml/s

Temporal precision

0.50 %

Sampling frequency

100 Hz

Calibration

Factory pre-calibrated; no prior calibration required

Use

Single-use; adult and paediatric

Presentation

Per unit (1 kit with 25 transducers)

Regulatory standard

Medical device compliant with Regulation (EU) 2017/745 (MDR); EN ISO 9001:2015 and EN ISO 13485:2016+A11:2021