Description
1. Introduction
The Corometrics thermal paper pad (ref. Cahnos 0553182) is the recording consumable that keeps the cardiotocographs of the MOD 115-116 series and the Series 120/170 operational in obstetric clinics, delivery rooms and maternal-fetal monitoring units. Its folded format of 152 × 90 mm with 160 sheets and its red grid guarantee a clear, stable and perfectly measurable recording of fetal heart rate (FHR) and uterine activity (UA) in each attendance. A reliable supply of recording paper ensures continuity of care and correct clinical documentation for each patient.
2. Technical Explanation
This pad uses direct thermal printing technology: the thermal head of the cardiotocograph transfers heat to the heat-sensitive layer of the paper and generates the trace without the need for ink, toner or ribbon, which reduces equipment maintenance and allows the recording to be obtained immediately after each test. The pre-printed red grid acts as a millimetric reference on the paper itself: it allows the heart rate scale (bpm), uterine activity and recording speed to be assessed, facilitating the clinical interpretation of the cardiotocogram. The Z-fold pad format is placed directly in the equipment tray, avoiding cuts and additional handling during continuous monitoring.
3. Technical Specifications
| Model | MOD 115-116 · Series 120/170 (compatible) |
| References | 0553182 – 29.152.00 – 7981 |
| OEM references of the equipment | 4305AA0 / 4305CAO (also cited as 2009828-AAO, 2009828-CAO, E9005HP and 30597226) |
| Fanfold dimensions | 152 mm × 90 mm (sheet) |
| Contents | 160 sheets per pad (Z-fold format / z-fold) |
| Grid colour | Red |
| Paper type | High-sensitivity thermal paper |
| Printing system | Direct thermal by printhead (no ink or toner) |
| Application | Cardiotocography (CTG): fetal recording and maternal-fetal monitoring |
| Presentation | Box of 20 units |
| Classification | Class I medical device (with measuring function) · CE marking |
| Storage | Cool, dry place (5-40 °C), away from direct sunlight and excessive humidity |
4. Equivalences and Cross-References
The original equipment references are 4305AA0 and 4305CAO (GE Healthcare / Corometrics), which also appear in catalogues as 2009828-AAO, 2009828-CAO, E9005HP and 30597226; this is the designation that should be used when ordering the original spare part. There is no cross-reference table validated by the equipment manufacturer that includes all brands on the market; the alternatives indicated below have been verified in catalogues from manufacturers and authorised distributors and must always be checked against the monitor manual before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GE Healthcare (Corometrics) | Fetal paper for Corometrics 111/112/115/116/118/120/126/128/129/150/151/170/171/172 | 4305AA0 / 4305CAO | Comparable by category (not interchangeable 1:1) | OEM reference from the monitor manufacturer; same dimensions 152 × 90 mm, red grid and sheets serialised in a pad; confirm presentation and number of sheets per pack against the box of 20 from Cahnos. |
| CardioRapid (distribution line) | Thermal paper pad Mod. 115-116 · Series 120/170 · Analogic FetalGuard 3000 | 0553085 (29.152.01 – 7982) | Comparable by category (not interchangeable 1:1) | Same format 152 × 90 mm × 160 sheets and red grid; also covers the Analogic FetalGuard 3000 (4303AA0/4305BA0/4305BIO/4305DAO); own catalogue SKU, confirm labelling. |
| PCI Charts (Precision Charts Inc.) | Corometrics Compatible B4305AAO, z-fold red grid | B4305AAO | Comparable by category (not interchangeable 1:1) | Format 152 mm × 47 ft in z-fold pad and red grid; manufacturer certified ISO 9001/13485; presentation in pack of 40 against box of 20 from Cahnos. |
| Distributors of the 152×90 format (Deseel Medical, Securlab and others) | Fetal paper compatible with Corometrics 115/116 and Series 120/170 | Standardised format 152 × 90 mm (without a single manufacturer SKU) | Not verified | They match the dimension 152 × 90 mm and the red grid; the number of sheets per pad varies (150-160) depending on the supplier; confirm sheets, grammage and fit of the pad before replacing. |
For the CTG format 152 × 90 mm with red grid, there is no equivalence table validated by the equipment manufacturer that cross-references all brands; consult the technical department before using in tenders.
5. Selection tips and variants of interest
Check the format before replacing: the three parameters that define this consumable are the width of 152 mm, 90 mm sheet length and the red grid. A different format (e.g. 100×100 or 145×100 mm) will not fit in the equipment compartment and will cause misaligned recordings. Confirm in the manual that your monitor prints via a thermal head and that the grid colour is the one indicated in your protocol (blocks with blue or other coloured grids are not interchangeable without prior verification).
In the Cahnos catalogue you will find variants of the same fetal recording family: the CardioRapid pad 0553085 (same format 152 × 90 × 160 sheets, also for Analogic FetalGuard 3000), the pad for Wakeling AFM 210 of 100 × 100 mm (ref. 0992006) and other CTG formats of 120 × 100 and 150 × 100 mm (refs. 0553173, 7962, 0992808 and 0992551), as well as the 140 mm × 43 m roll for CardioRapid (ref. 0553067). For hospitals and maintenance contracts we can schedule periodic deliveries; request a formal quotation from our technical-commercial team.
Store the pads in a cool, dry place (5-40 °C), away from direct sunlight and heat sources, to preserve the thermal sensitivity of the paper and prevent fogging of the heat-sensitive layer; correct storage ensures the clarity and durability of the trace in the clinical record.