Description
1. Commercial Introduction
The thermal paper pad for cardiotocograph reference 0553079-HP is the consumable that keeps the Philips / Hewlett Packard fetal monitors of the AVALON FM-20 and FM-30 series operational. Its Z-fold format of 150 × 100 mm with 150 sheets per pad and green grid is designed for continuous recording of fetal heart rate (FHR) and uterine activity (IUP) during antepartum monitoring and labour, in delivery rooms, obstetric clinics and maternal-fetal medicine units.
The presentation in a box of 20 pads allows planned and cost-effective replenishment, avoiding service interruptions. It reproduces the construction of the original Philips / HP M1911A (989803105501) reference and is available with delivery for replenishment orders and institutional supply contracts.
2. Technical Explanation
The AVALON series cardiotocographs record on thermochemical paper: the image is generated by contact of the thermal head on the heat-sensitive layer of the paper, without the need for ink, toner or ribbon, which reduces equipment maintenance. For the recording to be clinically interpretable, the paper must have a pre-printed reference grid that allows assessment of the amplitude of contractions (intrauterine pressure scale 0-100 mmHg and 0-13 kPa) and fetal heart rate (FHR scale 50-210 bpm), as well as the recording speed in mm/min.
This pad incorporates a stop cell (stop signal) on the last sheet to indicate the end of the pad, and its Z-fold facilitates continuous paper feeding, preventing jams, as well as allowing subsequent archiving of the trace in the clinical record. The grammage and thermal sensitivity are adjusted to the head of the AVALON monitors to guarantee sharp, stable and durable traces (trace shelf life of up to 5 years under appropriate archiving conditions).
3. Technical Specifications
| Characteristic | Detail |
|---|---|
| Reference Cahnos (SKU) | 0553079-HP |
| Equivalent original reference | Philips / HP M1911A · 989803105501 |
| Compatible models | Philips / HP M1350A, M1350B, M1350C, M1351A, M1353A, M2922A (FM-2), M2702A (AVALON FM-20), M2703A (AVALON FM-30); historical references M1323, M1324A, M1325A |
| Block dimensions | 150 mm (width) × 100 mm (length) × 150 sheets (≈15 linear metres) |
| Format | Z-fold, high-sensitivity thermochemical paper |
| Grid colour | Green |
| Printed scales | FHR 50-210 bpm · IUP 0-100 mmHg (0-13 kPa) |
| Stop cell | Yes (stop signal on the last sheet) |
| Print technology | Thermal printhead (thermochemical, no ink or toner) |
| Commercial presentation | Box of 20 pads |
| Application | Fetal cardiotocography (CTG): recording of FHR and uterine activity |
| Regulatory classification | Class I medical device (with measuring function) · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC |
| Trace shelf life | 5 years after printing (see product instructions) |
| Storage | Cool, dry place (5-40 °C); avoid direct sunlight, excessive humidity and heat sources |
4. Equivalences and Cross-References
The original equipment reference for this pad is Philips / HP M1911A (989803105501), confirmed in the official Philips datasheet (Z-fold thermochemical paper with green grid and stop signal). There is no official equivalence table published by the equipment manufacturer that authorises third-party consumables for this reference; the following references are offered as functional comparisons verified in catalogues of authorised manufacturers or distributors and must be confirmed with the technical department before use in tendering.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Danlee Medical (USA) | Philips M1911A Compatible Fetal Monitoring Recording Paper | 9024731 | Comparable by category (not interchangeable 1:1) | Same format 150 × 100 mm × 150 sheets with green grid and stop cell; the manufacturer declares equivalence with Philips M1911A / 989803105501. Confirmed in the manufacturer’s datasheet. |
| Diagramm Halbach (Germany) | CTG Paper Z-fold M1911A (CTG folded paper) | 131537 | Comparable by category (not interchangeable 1:1) | 150 × 100 mm, 150 sheets (15 m), green grid with three scales (0-12, 0-100, 60-200), without perforations; for HP M1350A/M1356A and Philips Avalon series. Confirmed on the manufacturer’s website. |
| Quality Chart Paper (Canada) | Hewlett Packard M1911A Chart Paper (151 × 100 × 150) | M1911A / KB 3002025 | Comparable by category (not interchangeable 1:1) | 151 mm × 100 mm × 150 sheets with green grid; cross reference KB 3002025. Confirmed in the distributor’s catalogue. |
Remember that the version with red grid of this same format corresponds to the original Philips / HP M1910A reference (in Cahnos, ref. 0553174); the green grid version in this datasheet corresponds to the M1911A. There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
5. Selection tips and variants of interest
Always check the grid colour: this datasheet corresponds to green grid (original M1911A). The original Philips M1910A is marketed with red grid. Before replacing one consumable with another, confirm on the equipment which grid colour is programmed or legible for your service, as the pre-printed scale must match the one configured on the monitor.
Check the folding format: this pad is Z-fold with stop cell, the standard format for AVALON FM-20 / FM-30. If your equipment uses a continuous roll, it is not interchangeable without mechanical adaptation. The three parameters that define this consumable are the width of 150 mm, the sheet depth of 100 mm and the number of 150 sheets; a different format (e.g. 120 × 100 mm or 142 × 150 mm) will not fit in the equipment compartment.
Variants of the same family in Cahnos: fetal thermal pad with red grid for AVALON FM-20 / FM-30 equivalent to M1910A (ref. 0553174) and pad of 150 × 100 × 150 sheets in green grid for Advanced Medical System AM 67 (ref. 0553079-AM). Storage: keep the pads in a cool, dry place (5-40 °C), protected from direct sunlight and heat sources, to preserve the thermal sensitivity of the paper and avoid fogging of the heat-sensitive layer; correct storage guarantees the sharpness and durability of the trace in the clinical archive during its 5-year service life.