We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Double Twin Fetal Monitor with 7″ TFT Touchscreen | CTG Cardiotocograph with STV Analysis, US Catheter 1 MHz, A5 Printer and Free Software | Ref. 35.11-4200

2.518,20 €

Double (twin) fetal cardiotocograph with a 7″ colour TFT touchscreen, two high-sensitivity ultrasound catheters of 1 MHz for simultaneous monitoring of two fetuses and TOCO catheter for uterine contractions. Includes CTG analysis with STV parameter, integrated thermal printer in A5 format, 72-hour trend storage with export to USB memory, free archiving and analysis software, and complete set of accessories. Compact dimensions of 296 × 305.5 × 97.5 mm and only 2.9 kg, with mains or rechargeable battery power. Ideal for obstetric clinics, prenatal monitoring rooms and pre-labour wards.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
35.11-4200

Description

1. Dual fetal monitor with touchscreen: complete control of fetal and maternal wellbeing

The twin fetal monitor with 7″ touch screen (Ref. 35.11-4200) is a tabletop cardiotocograph designed for continuous monitoring of fetal wellbeing in obstetric clinics, gynaecological practices, antenatal control rooms and pre-labour rooms. Its twin configuration allows simultaneous recording of the heart rate of two fetuses and maternal uterine activity on a single colour TFT touch screen, with an intuitive interface that streamlines the professional’s work. It includes CTG analysis with STV parameter, integrated thermal printer in A5 format, 72-hour trend storage with export to USB memory and free archiving and analysis software. A compact (2.9 kg) and complete solution, ready to use with all its accessories included.

2. Technical explanation of the equipment

The equipment uses external cardiotocography (CTG) technology: two highly sensitive 1 MHz ultrasound transducers capture the fetal heart rate (FHR) of both fetuses using the Doppler effect, while the external pressure TOCO probe records uterine dynamics (contractions). The system processes the signals in real time and displays them on the 7″ TFT touch screen, where the FHR curves of each fetus, the tocography and the fetal movements marked by the patient using the event marker can be viewed simultaneously.

The integrated CTG analysis includes the calculation of the STV parameter (short-term variation), one of the most widely used numerical indicators for assessing fetal health in antepartum recording, along with other trace parameters. The integrated thermal printer documents the records in A5 format, and the internal memory stores up to 72 hours of trends, which can be exported to a USB flash drive (JPEG) or sent to the included free software for storage, subsequent analysis and integration into the centre’s clinical documentation.

3. Technical Specifications

Characteristic Specification
Set type Dual/twin fetal cardiotocograph (CTG) with touchscreen
Display 7″ colour TFT touchscreen, clear real-time display
Fetal channels 2 (simultaneous monitoring of two fetuses)
Ultrasound transducers 2 × high-sensitivity 1 MHz transducers
Tocography transducer 1 × external pressure TOCO probe (uterine activity)
CTG analysis Integrated, with STV parameter (short-term variation)
Printer Built-in thermal printer; CTG reports in A5 format
Data storage 72-hour trends; export to USB flash drive (JPEG)
Software Free software for PC archiving and analysis
Event marker Yes, to record fetal movements perceived by the mother
Power supply Mains power or battery; 100–240 V AC, 50–60 Hz, 1.5 A
Consumption 60 W max.
Battery Built-in rechargeable battery (approx. 2 hours of autonomy)
Dimensions 296 × 305.5 × 97.5 mm (width × depth × height)
Weight 2.9 kg
Safety Class II / Type BF (IEC 60601-1)
Operating temperature 10–40 °C
Relative humidity 30–85 %
Atmospheric pressure 70–106 kPa
Standard accessories included 2 ultrasound transducers, 1 TOCO probe, 1 event marker, 3 belts, 1 paper roll and 1 gel
Warranty 24 months (CE marking, Medical Devices Directive)

4. Equivalences and Cross-References

This cardiotocograph belongs to the series of dual-channel fetal monitors with 7″ touch screen and 1 MHz probe in our catalogue. There is no manufacturer-validated equivalence table authorising 1:1 replacement with equipment from other brands; the following comparisons are functional, at category level, and should not be treated as interchangeable without prior technical validation from the relevant department. Before any replacement, the following must be checked one by one: number of fetal channels, frequency and type of probes, available CTG analysis (STV, Fischer, Dawes-Redman…), print format, storage, connectivity and CE/MDR regulatory classification.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Bionet FC1400 twin cardiotocograph, 7″ TFT touchscreen FC1400 Comparable by category (not interchangeable 1:1) Antepartum fetal monitor with real-time twin FHR detection and uterine activity, 7″ touch screen and CTG analysis. Same functional family; verify probe frequency, analysis criteria and consumables.
Goldway Medical CTG7 fetal monitor with 7″ screen CTG7 Comparable by category (not interchangeable 1:1) 7″ screen, integrated thermal recorder and FHR/TOCO measurement. Comparable bedside unit; confirm twin configuration, CTG analysis and standard accessories before replacing.
Huntleigh Healthcare Sonicaid Team 3 series (Team 3A/3I) Team 3 Comparable by category (not interchangeable 1:1) Higher range with 8.4″ colour touch screen, Dawes-Redman CTG analysis, maternal vital signs options and twin/triplet capability. It matches the touch screen and dual fetal monitoring, with higher features and price.

Other homologous families of bedside cardiotocographs on the market (Philips Avalon, GE Corometrics, Edan, Contec, among others) must be reviewed property by property: number of fetal channels, probe frequency (1 MHz vs 2–3 MHz), CTG analysis (STV, Fischer, NST, Krebs, Dawes-Redman), paper format, memory and connectivity, and regulatory classification. There is no manufacturer-validated equivalence table; consult the technical department before using in tenders. In our catalogue, the family of bedside fetal monitors is completed with the individual Smart 1 model (Ref. 35.11-7000), the twin EcoTwin LCD (Ref. 35.71-3480) and EcoTwin LED (Ref. 35.71-3490) and the professional 21A/21B/MCF-21K series with Linux platform.

5. Selection tips and variants of interest

Why choose this equipment: if your centre handles twin pregnancies or needs to simultaneously record the FHR of two fetuses along with uterine dynamics on a touch screen, this twin cardiotocograph is the balanced option between features and cost. Its weight of 2.9 kg allows it to be easily moved between consulting rooms and pre-labour rooms.

Variants of interest in our catalogue:

  • Smart 1 (Ref. 35.11-7000): individual fetal monitor from the same series, with a 1 MHz ultrasound probe, wide printing and complete accessories; indicated for antenatal care of single pregnancies on a lower budget.
  • EcoTwin LCD (Ref. 35.71-3480) and EcoTwin LED (Ref. 35.71-3490): dual-screen monitors with 270° rotating screen, lithium-ion battery, USB storage and compatibility with HP paper; an alternative with dual physical display.
  • Series 21 (MCF21A, MCF21B, MCF21K): professional cardiotocographs with Linux platform, screens from 8″ to 12.1″, 112 mm thermal printer, advanced analysis (Fischer, NST, Krebs, Dawes-Redman) and optional HL7 connectivity for hospital environments and delivery rooms.

Consumables and accessories: check the thermal paper compatible with the integrated A5 printer, have specific ultrasound transmission gel available and replace the transducer securing straps (e.g., set of disposable CTG bands). For tenders, volume conditions or validation of alternative equipment from other brands, contact our technical-commercial team.

Additional information

Product type

Dual/twin fetal cardiotocograph (CTG) with touchscreen

Display

7" colour TFT touchscreen

Fetal channels

2 (simultaneous monitoring of two fetuses)

Ultrasound transducers

2 × high-sensitivity 1 MHz transducers

TOCO probe

1 × external pressure TOCO transducer

CTG analysis

Integrated, with STV parameter (short-term variation)

Printer

Built-in thermal printer, A5 reports

Storage

72-hour trends; export to USB flash drive (JPEG)

Software

Free software for PC archiving and analysis

Event marker

Yes

Power supply

Mains power or battery; 100–240 V AC, 50–60 Hz, 1.5 A

Consumption

60 W max.

Battery

Built-in rechargeable battery (approx. 2 hours of autonomy)

Dimensions

296 × 305.5 × 97.5 mm

Weight

2.9 kg

Safety

Class II / Type BF (IEC 60601-1)

Operating temperature

10–40 °C

Relative humidity

30–85 %

Atmospheric pressure

70–106 kPa

Included accessories

2 ultrasound transducers, 1 TOCO probe, 1 event marker, 3 belts, 1 paper roll and 1 gel

Warranty

24 months (CE marking / MDD)

Intended use

Obstetrics clinics, prenatal care, delivery rooms and twin pregnancies

Reviews

There are no reviews yet.

Be the first to review “Double Twin Fetal Monitor with 7″ TFT Touchscreen | CTG Cardiotocograph with STV Analysis, US Catheter 1 MHz, A5 Printer and Free Software | Ref. 35.11-4200”

Your email address will not be published. Required fields are marked *