Non-sterile Hudson gas sampling adapter (Medline) – Angled connector 15M to 15F/22M, 360° sampling port female luer-lock | Box of 50 units | Ref. 1624

Price on request

The non-sterile Hudson gas sampling adapter from Medline (Ref. 1624) is a disposable accessory with an angled connector, designed for installation in ventilation or aerosol circuits. It incorporates a 360° rotatable gas sampling port with female luer-lock connection, which allows redirecting flow and extracting gas samples (CO₂) or monitoring pressure without interrupting the circuit. Connection 15-M to 15-F/22-M, supplied in a box of 50 units. Product subject to quotation: consult B2B conditions with the technical-commercial team at Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
MDLP-LJ64Q

Description

1. Commercial Introduction

The non-sterile Hudson gas sampling adapter, manufactured by Medline, is a disposable accessory designed for pulmonology, ICU, anaesthesia and emergency departments that need to take gas samples or monitor patient ventilation without disconnecting the circuit. Its angled connector adapts to ventilation and aerosol circuits, and its 360° rotatable sampling port facilitates healthcare professional access in any position. It is supplied in packs of 50 units and belongs to the Medline P-LJ64Q family, within the Respiratory \u003E Oxygen therapy range.

2. Technical explanation of the adapter

This adapter is inserted into the respiratory circuit between standard connectors, acting as a flow direction redirection element. Its 360-degree gas sampling port, with female luer-lock connection, allows attachment of capnography sampling lines, pressure transducers or other diagnostic devices in the most convenient orientation, without generating tension on the tubing or interrupting ventilation. Being a non-sterile product, it is intended for use with single-care-cycle patients in conventional hospital settings.

3. Technical Specifications

Available references

Reference Port Diameter Diagnostic Port Units per box
1624 15M to 15F/22M Yes 50

Features

  • Brand: Medline (family P-LJ64Q).
  • Connector type: Angled, for ventilation or aerosol circuits.
  • Connection: 15-M to 15-F/22-M.
  • Gas sampling port: 360°, female luer-lock.
  • Intended use: Redirection of flow direction in ventilation, incl. gas sampling (Ventilation redirection incl. Gas sampling).
  • Sterility: No.
  • Presentation: Box of 50 units.

4. Equivalences and Cross-References

The product corresponds to reference 1624 (SKU Cahnos MDLP-LJ64Q, family Medline P-LJ64Q) within the range of monitoring adapters of the Hudson/Medline line. Comparable references from the same manufacturer include the Hudson straight monitoring adapter (ref. 41669, SKU MDLP-HX43G), with the same 15-M to 15-F/22-M connection and port with luer-lock cap but without rotating elbow, and the Hudson pressure line adapter with 360° monitoring elbow (ref. 41642, SKU MDLP-HX51R), for 22-M and 22-F connections. No 1:1 equivalence table validated by the manufacturer against codes from other suppliers has been found in reliable sources; in the market, comparable families by category are the sampling adapters and monitoring elbows for respiratory circuits from brands such as Teleflex (Hudson RCI line), whose fit must be confirmed field by field (connection diameter, presence of diagnostic port and connector type) with the technical department before any substitution.

5. Selection tips and variants of interest

To select the appropriate sampling adapter, verify: 1) the diameter of your circuit connectors (15M/15F-22M in this model; 22M/22F in the elbow adapter ref. 41642); 2) the need for a diagnostic port for gas sampling or pressure measurement; and 3) the preferred configuration: 360° rotatable angled elbow (this model), straight port with luer-lock cap (ref. 41669) or double-swivel elbow for 22 mm circuits (ref. 41642). Single-patient product, non-sterile, supplied in a box of 50 units. For B2B volume quotes and conditions, contact the technical-commercial team at Cahnos.

Additional information

Brand

Medline

References

1624

Port Diameter

15M to 15F/22M

Sales unit

Box (Case) of 50 units

Manufacturer reference

1624

Family

P-LJ64Q

Connection

15-M to 15-F/22-M

Connector type

Angled (elbow), for ventilation or aerosol circuits

Diagnostic port

Yes, 360° gas sampling port with female luer-lock connection

Intended use

Redirection of flow direction in ventilation, incl. gas sampling

Sterility

No

Presentation

Box of 50 units

Documentation

Reviews

There are no reviews yet.

Be the first to review “Non-sterile Hudson gas sampling adapter (Medline) – Angled connector 15M to 15F/22M, 360° sampling port female luer-lock | Box of 50 units | Ref. 1624”

Your email address will not be published. Required fields are marked *