Description
1. Commercial Introduction
Keep your Schiller family defibrillator always operational with this pair of standard adult defibrillator electrodes with external cable (reference Cahnos F7956W). It is the replacement consumable indicated for defibrillation of adult patients with the FRED Easy, FRED Easy 2G and Defigard DG 4000, DG 5000 and DG 6002 equipment, the AEDs and defibrillators/monitors most widely used in emergency services, ambulances, health centres, companies and cardioprotected spaces.
Its external cable configuration allows the pair to be left connected to the equipment with the connector accessible: at the critical moment, simply remove the packaging protector and place the pads following the anatomical diagrams on the pouch, minimising preparation time. It is sold per pair (2 units) in an individual heat-sealed package, with immediate delivery and specialised technical support from Cahnos to verify compatibility by model and connector before placing the order.
2. Technical explanation of the procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them, the equipment analyses the heart rhythm, delivers the transthoracic shock and allows emergency ECG monitoring. This pair is indicated for adult patients (over 8 years old or over 25 kg) and connects to the electrode socket of the mentioned Schiller equipment via its external cable configuration with a safety anti-shock connector.
The low-impedance conductive adhesive gel ensures homogeneous skin contact, low interface resistance and optimal transmission of shock energy; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the chest contours, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), so that both pads do not come into contact with each other. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the package.
3. Technical Specifications
3.1 Product identification
| Parameter | Specification |
| Reference Cahnos (SKU) | F7956W |
| Product type | Pair of adult multifunction defibrillator electrodes, standard, with external cable |
| Brand / compatible equipment | Schiller – FRED Easy, FRED Easy 2G, Defigard DG 4000, DG 5000 and DG 6002 |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Presentation | Price per pair (2 units); heat-sealed packaging; 10 pairs per box (adult series) |
3.2 Technical features
| Parameter | Specification |
| Cable configuration | External cable (accessible plug-in connector), approximate length of 120–130 cm in the series |
| Total surface (per electrode) | 148 cm² |
| Active surface (per electrode) | 95 cm² |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (50 to 360 J) |
| Functions | Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector or clip (depending on model), with external cable |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Shelf life | Approx. 30 months from the date of production; expiry indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C |
3.3 Compatibility with defibrillators
| Equipment brand | Compatible models | Required connection |
| Schiller | FRED Easy, FRED Easy 2G, Defigard DG 4000, Defigard DG 5000, Defigard DG 6002 | Safety anti-shock connector; external cable |
Note: the values for active surface area (95 cm²), total area (148 cm²), shocks (50–360 J) and adhesive ring (1 cm) correspond to the standard adult electrodes with external cable series of this product family; confirm with the technical data sheet of the supplied batch and the equipment manual before use in tender.
4. Equivalences and Cross-References
Reference F7956W is the Cahnos distribution code for this standard adult electrode with external cable compatible with the Schiller FRED Easy / Defigard platform; it is not an official reference of the equipment manufacturer. The connector and energy management of each defibrillator are proprietary, so equivalences with other references are considered comparable at category level and not interchangeable 1:1. The original factory replacement from Schiller for the FRED Easy / Defigard family is identified by code 0-21-0020 (also 2.230344), consistently confirmed in authorised Schiller original spare parts distribution; this original comes pre-connected with an internal cable of 40 cm and an active surface area of approximately 80 cm², compared to the external cable configuration and 95 cm² active surface area of reference F7956W.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Schiller (original equipment replacement) | Original pre-connected adult electrodes for FRED Easy, FRED Easy 2G and Defigard DG 4000/5000/6002 | 0-21-0020 (also 2.230344) | Comparable by category (not interchangeable 1:1) | Original factory replacement for the same equipment; it comes pre-connected with an internal cable of 40 cm and an approximate active surface area of 80 cm² per electrode, compared to 95 cm² with external cable of this reference. Code confirmed in authorised Schiller original spare parts distribution. |
| ZOLL Medical | Stat-Padz II – adult multifunction electrode (AED Plus / AED Pro) | 8900-0801-01 | Comparable by category (not interchangeable 1:1) | Factory original pre-connected with polymer conductive gel for ZOLL AEDs; proprietary connector, algorithm and energy management. Code confirmed on the official ZOLL website and in GUDID/FDA. Not suitable for Schiller equipment due to proprietary connector. |
| Philips | HeartStart FRx SMART Pads II (adult/child electrodes) | 989803139261 | Comparable by category (not interchangeable 1:1) | Universal electrodes for the FRx family covering adult and paediatric use via the Infant/Child Key; proprietary connector and energy management of Philips. Code confirmed in the official store; does not fit Schiller equipment. |
There is no equivalence table validated by the manufacturer that authorises the replacement of Schiller original electrodes with third-party pads: the connector, analysis algorithm and energy management are proprietary. Any substitution must be validated against the technical data sheet and instructions for use of the defibrillator; consult with the technical department of Cahnos before use in tender.
5. Selection tips and variants of interest
- Confirm the equipment model: verify that your defibrillator is a Schiller FRED Easy, FRED Easy 2G or Defigard DG 4000 / DG 5000 / DG 6002 and that the external cable connector fits correctly into the equipment’s electrode socket before clinical use; if in doubt, contact the technical department of Cahnos providing the model and serial number.
- Do not confuse versions: this pair is for adult patients (over 8 years / over 25 kg). For the paediatric population with the same equipment, use reference F7956PW (external cable) or F7956P (internal cable).
- External cable vs. pre-connected: the external cable configuration leaves the connector accessible to plug the pair into the equipment at the precise moment, reducing preparation time in cardioprotected spaces and ambulances; if your workflow requires leaving the equipment permanently connected, consider the original pre-connected variant from Schiller (0-21-0020 / 2.230344).
- Other variants of the same connector family: version with internal cable (F7956) if you prefer a direct connection without loose cables, and radiolucent version with internal cable (F7756) if X-rays or CT scans are anticipated during care. The family for FRED EasyPort / FRED PA-1 / Defigard Touch 7 uses reference F7967W, with a different connector.
- Check the expiry date: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; do not use expired electrodes or those with damaged packaging, as the gel may lose conductivity.
- Plan your replenishment: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO method). For volume orders or tenders, contact the technical department of Cahnos, quoting the exact model and serial number of your device.