Description
1. Commercial Introduction
Keep your Marquette GE or Esaote defibrillator-monitor always operational with this pair of standard adult defibrillator electrodes with internal cable (reference Cahnos F7962). It is the replacement consumable that ensures direct connection between the equipment and the patient at the critical moment of cardiopulmonary arrest: a single pair of disposable pads allows the rhythm to be analysed, the shock to be delivered and the emergency electrocardiogram to be monitored without loose cables during the procedure.
It is the ideal solution for hospital emergency departments, intensive care units, ambulances, cardiology clinics and cardioprotected spaces with this equipment in service. Available with immediate dispatch from Cahnos and specialised technical support to verify compatibility by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock, enables non-invasive transcutaneous cardiac pacing (if the equipment supports it) and monitors the emergency electrocardiogram. This pair is indicated for adult patients (over 8 years of age or weighing more than 25 kg) for external defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring.
The integrated internal cable configuration (direct connection or direct-wired) connects the pad directly to the equipment’s electrode socket, without the need for an intermediate adapter cable and without the external GE 22338301 cable: at the critical moment you only need to remove the protective cover from the pouch and place the pads following the anatomical diagrams. The low-impedance conductive adhesive gel ensures homogeneous contact with the skin and optimal energy transmission; the metallic foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest. The recommended placement is anterolateral (sternum-apex), without the two pads coming into contact with each other. They are single-use: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
Main features of the standard adult electrode series with internal cable to which this reference belongs (Ref. Cahnos F7962):
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7962 |
| Product type | Pair of adult multifunction defibrillator electrodes, standard, with internal cable (direct connection) |
| Compatible equipment brands | Marquette GE and Esaote |
| Compatible models cited | Marquette 1250 First Responder, 1500 First Responder, Responder 2000 (documented family: Responder 3000); Esaote MDF and MDF Plus (verify connector) |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | Integrated internal cable: direct connection to the equipment’s electrode socket (without GE 22338301 cable) |
| Connection type | Safety anti-shock connector / clip (depending on model), with internal cable |
| Total surface (per electrode) | 148 cm² (adult series) |
| Active surface (per electrode) | 95 cm² (adult series) |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (50 to 360 J in adult configuration) |
| Functions | External defibrillation, synchronized cardioversion, non-invasive transcutaneous pacing and ECG monitoring |
| ECG monitoring | Up to 24 h |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium bag; 10 pairs per box (adult series) |
| Operating temperature | Between 0 °C and +50 °C |
| Storage | Dry place, between +5 °C and +35 °C |
| Shelf life | Approx. 30 months from the date of manufacture; expiry date indicated on the packaging |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
Technical note: the active surface values (95 cm²), total area (148 cm²), shocks (50–360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with internal cable of this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tendering.
3.1 Compatibility with defibrillators
| Equipment brand | Compatible models | Cable / connection |
|---|---|---|
| Marquette GE | 1250 First Responder, 1500 First Responder, Responder 2000 (documented family: Responder 3000) | Equipment internal cable; verify connector fit |
| Esaote | MDF, MDF Plus (documented family) | Equipment internal cable; confirm the exact model and connector before replacement |
Always verify the correct fit of the connector in the equipment’s electrode socket before clinical use.
4. Equivalences and Cross-References
Reference F7962 is the Cahnos distribution code for this adult electrode compatible with Marquette GE and Esaote; it is not an official reference of the equipment manufacturer. The connector, analysis algorithm and energy management of each defibrillator are proprietary, so equivalences with other brands are considered comparable at category level and not interchangeable 1:1. The following cross-references have a confirmed code in public sources (authorised manufacturer-distributor catalogue, official manufacturer website and/or GUDID regulatory database):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| AB Medica Group (Lessa) | Adult electrodes for GE Marquette Responder 2000 (without GE 22338301 cable) | 99.835.24 | Comparable by category (not interchangeable 1:1) | Same functional profile: adult electrode for the GE/Marquette platform with internal cable and connector included, without external cable 22338301. Code confirmed in the manufacturer-distributor’s technical data sheet and in the family’s technical documentation; proprietary connector and discharge protocol of the equipment. Verify fit before replacement. |
| ZOLL Medical | Stat-Padz® II – adult multifunction electrodes (AED Plus / AED Pro) | 8900-0801-01 | Comparable by category (not interchangeable 1:1) | Factory-original pre-connected for ZOLL AEDs; low-impedance polymer conductive gel and proprietary ZOLL connector. Code confirmed on the official ZOLL web store and in GUDID. Not suitable for Marquette GE/Esaote equipment due to proprietary connector and algorithm. |
| Philips | Adult/Child Pads with barrel connector (adult/child ≥ 10 kg, HeartStart MRx / XL / XL+ and CodeMaster family) | M3501A (also 989803106921) | Comparable by category (not interchangeable 1:1) | Multifunction electrode with barrel connector; requires M3507A/M3508A cables depending on model. Code confirmed in Philips technical documentation and in GUDID/FDA. Proprietary connector and energy management, not suitable for the electrode socket of Marquette GE/Esaote equipment. |
There is no equivalence table validated by the manufacturer (GE Healthcare / Esaote) that authorises the replacement of original pads with third-party electrodes: defibrillation platforms use proprietary connectors, analysis algorithms and energy management and are not interchangeable 1:1 between brands (e.g. Philips HeartStart, ZOLL, Schiller, Stryker LIFEPAK or Bexen). Consult Cahnos’s technical department before use in tenders.
5. Selection tips and variants of interest
Confirm the model and connector of the equipment: verify that your defibrillator is a Marquette GE (1250 or 1500 First Responder, Responder 2000/3000) or an Esaote (MDF, MDF Plus) with direct internal cable connection (without external GE 22338301 cable). Do not use this pair on equipment with a different connector (e.g. systems with external cable or Snap-type connection). If in doubt, contact Cahnos’s technical department stating the model and serial number.
Do not confuse the adult and paediatric versions: this pair is for patients over 8 years old or over 25 kg. For the paediatric population of the same connector family, reference F7962P is available (standard paediatric with internal cable, Marquette GE/Esaote).
Variants of the same family at Cahnos: for the Marquette GE/Esaote platform with Snap connection on GE 22338301 cable, F7972 (adult) and F7972P (paediatric) are available; for GE Responder 3000/2000/1100, CardioServ and Dash Responder equipment with direct connection, F7981; if you need radiotransparent electrodes for imaging control on the same Marquette/Esaote platform, consider F7762. Always verify which connector family corresponds to each defibrillator.
Storage and expiry: check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to expiry date (FIFO). For volume orders or tenders, contact Cahnos’s technical-commercial department stating the exact models of your fleet.