1. Commercial Introduction
The PREMISUT PRIME polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with total control. This presentation in USP 2/0 gauge, with a ½ circle needle with a grooved conical point of 30 mm (HR30 Prime profile) and a double blue thread of 75 cm (2×75 cm), is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, which facilitates hospital stock management and presentation to public tenders. Factory reference P732HR3020.2, marketed by Cahnos as SKU AMP732HR3020.2, maintaining the manufacturer’s official nomenclature without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer, (C3H6)n) that is presented as a non-coated monofilament, dyed blue for maximum visibility in the surgical field. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, helping the wound for more than three months.
The HR30 Prime needle (½ circle, cylindrical body and grooved Taperpoint conical point of 30 mm) separates and displaces tissue fibres without cutting them, making it ideal for soft, vascular and poorly distensible planes that require controlled penetration and minimal injury. The grooved finish of the needle body improves grip in the needle holder and facilitates smooth and consistent delivery during knotting. The double thread presentation (2×75 cm) allows continuous suture techniques and anastomosis with two armed ends without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Line | Premisut – Prime quality (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, non-coated, dyed blue (synthetic linear polyolefin, ≥ 99.5% polypropylene / ≤ 0.5% phthalocyanine) |
| Thread structure | Monofilament, needle with grooved body (HR30 Prime profile) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Number of threads | 2 threads per pack |
| Thread length | 2 × 75 cm (two threads of 75 cm) |
| Thread colour | Identifying blue, high visibility on the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), grooved |
| Needle size | 30 mm (HR30 Prime profile) |
| Manufacturing quality | Prime (premium range, improved penetration needle) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732HR3020.2 |
| Reference Cahnos (SKU) | AMP732HR3020.2 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Gauge equivalence according to USP/EP standard (non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.349 mm |
Variants of the HR30 Prime family (½ circle, Taperpoint conical point, 30 mm needle)
| Needle profile | USP size | Presentation | Reference |
|---|---|---|---|
| HR30 Prime | 2/0 | 2 × 75 cm | P732HR3020.2 / AMP732HR3020.2 (this product) |
| HR30 Prime | 2/0 | 1 × 75 cm | P732HR3020 / AMP732HR3020 |
| HR30 Prime | 0 | 2 × 75 cm | P732HR3010.2 / AMP732HR3010.2 |
| HR30 Prime | 3/0 | 2 × 75 cm | P732HR3030.2 / AMP732HR3030.2 |
| HR30 (standard) | 2/0 | 1 × 75 cm | 732HR3020 / AM732HR3020 |
| 2×HR30 Prime | 2/0 | 2 × 90 cm | P733HR3020-2 / AMP733HR3020-2 |
4. Equivalences and Cross-References
The reference P732HR3020.2 corresponds to the official nomenclature of the Premisut Prime range (grooved HR30 Prime profile, double thread of 75 cm, USP 2/0 gauge, blue colour). Cahnos markets the product maintaining the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the comparisons between brands indicated below are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene HR30 Prime, USP 2/0, blue, 1 × 75 cm | P732HR3020 / AMP732HR3020 | Configuration equivalent within the same system | Same grooved HR30 needle and USP 2/0 gauge; the presentation changes to single thread |
| Cahnos (Premisut standard) | Polypropylene HR30, USP 2/0, blue, 1 × 75 cm | 732HR3020 / AM732HR3020 | Direct equivalent within the same family | Same dimensions and material; standard quality needle versus Prime |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 75 cm, CT-1 ½ circle taper point needle | 8423H | Comparable by category (not interchangeable 1:1) | Verified in official Ethicon catalogue and authorised distribution. Material, gauge, colour and length (75 cm) match; the CT-1 needle is 36 mm and non-grooved compared to the grooved HR30 of 30 mm. Box of 36 units. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene, USP 2/0, 75 cm, CT-2 taper point needle | 8411H | Comparable by category (not interchangeable 1:1) | Verified in official Ethicon catalogue. Same gauge, colour and length (75 cm); CT-2 needle of 26 mm compared to HR30 of 30 mm. Box of 36 units. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene (with polyethylene) blue monofilament, ½ circle conical point | VP843 | Comparable by category (not interchangeable 1:1) | Verified in authorised distribution. Same gauge and conical point; copolymeric material (polypropylene/polyethylene) and V-26 needle of 26 mm compared to 30 mm; strand of 90 cm. Confirm in official catalogue. |
| B. Braun | Premilene® – blue monofilament polypropylene, USP 2/0, 75 cm, HR30 EasySlide ½ circle conical point needle | C2090047 | Comparable by category (not interchangeable 1:1) | Verified in official B. Braun catalogue and AccessGUDID. Material, gauge, colour, conical HR30 needle and length (75 cm) match; single thread presentation compared to double thread 2×75 cm. |
| DemeTECH | DemeLENE® – blue monofilament polypropylene, USP 2/0, 75 cm, DCT-2 round body ½ circle needle | PM292026B1P | Comparable by category (not interchangeable 1:1) | Verified in official DemeTECH store. Same gauge, colour and length; DCT-2 needle of 26 mm round body, without grooved channel, compared to grooved HR30 of 30 mm. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene® or DemeLENE® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the HR30 needle with grooved Taperpoint conical point is indicated for soft, vascular and poorly distensible planes that require non-cutting penetration (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar point profiles (HRT) or triangular profiles from the same Premisut Prime range.
Needle size: the HR of 30 mm is ideal for medium-depth fields. If you need a shorter needle, the HR 25 is available (ref. AMP732HR2520.2); for wider planes, the HR 35 (ref. AMP732HR3520.2) or HR 40 (ref. AMP732HR4020.2) in USP 2/0 gauge and double thread presentation.
Gauge: the USP 2/0 (metric 3) offers an excellent balance between strength and manageability for vascular ligatures and soft tissues. If the protocol requires a smaller diameter, the same HR30 Prime family offers 3/0 (ref. AMP732HR3030.2) or 0 (ref. AMP732HR3010.2); for greater strength, USP 1 with the same needle.
Presentation: the double-thread 2×75 cm version optimises usage per procedure and reduces the opening of packaging; if you prefer one package opening per use, consider the single-thread version P732HR3020 (SKU AMP732HR3020) or the standard alternative without the Prime range AM732HR3020. For a longer thread length, the 2×90 cm version from the 733 series is available (ref. AMP733HR3020-2).
Prime range: the Premisut Prime line maintains the geometry of the standard version with an improved needle finish (superior penetration), useful when the protocol requires premium quality on delicate tissues. Always verify USP gauge, colour, thread length and needle size before placing the order; keep the reference P732HR3020.2 and the batch number for traceability in the operating theatre. Single-use product, not re-sterilisable; store below 30 °C, away from moisture and direct sunlight.





Reviews
There are no reviews yet.