We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

SILK Suture PREMISUT PRIME 5/0 (EP 1) Non-Absorbable · ½ Circle Conical Point Needle 16 mm (HR16 Prime) · Black Braided Thread 75 cm · Box of 12 units (Ref. P542HR1650)

Original price was: 24,90 €.Current price is: 18,10 €.

Non-absorbable suture of 100% natural braided silk PREMISUT PRIME, gauge USP 5/0 (metric EP 1), with black non-fluted thread 75 cm coated with wax and silicone. Mounts a ½ circle atraumatic conical point needle (HR16 Prime profile) of 16 mm, ideal for soft tissues, ligatures, ophthalmology and skin surgery. Very secure knot (technique 2 = 1 = 1 = 1) and wound support over 3 months. Sterilised by ethylene oxide, single-use; box of 12 units. Ref. P542HR1650 · SKU AMP542HR1650. Minimum order 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP542HR1650

Description

1. Commercial Introduction

The PREMISUT PRIME SILK Suture is the precision reference of the non-absorbable range from Cahnos for the professional seeking a natural-origin thread that is manageable and has predictable clinical behaviour. This configuration (Ref. P542HR1650 · SKU AMP542HR1650) combines a 100% natural braided silk multifilament, coated with wax and silicone and with a non-grooved Prime finish, in high-visibility black, USP 5/0 (metric EP 1) gauge, with a 75 cm strand mounted on a ½ circle taper-point needle of 16 mm.

Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability and a minimum order of 30 boxes. It is the usual choice in skin surgery, ophthalmology, plastic and reconstructive surgery departments and purchasing centres looking for a permanent thread with an excellent price-quality ratio for hospital replenishment, tenders and volume contracts.

2. Technical explanation

Surgical silk is a natural protein fibre (fibroin) transformed into a braided multifilament suture, whose filaments are washed, degummed, dyed black and coated with a mixture of wax and silicone. This coating reduces capillarity and tissue drag, improves the sliding of the strand through tissue and guarantees a firm and secure knot with the recommended knotting technique 2 = 1 = 1 = 1, one of the most valued qualities of surgical silk.

Being a non-absorbable material, the thread does not degrade enzymatically: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HR16 needle of 16 mm has a ½ circle curvature with a conical point (taper point): the cylindrical body and sharp point separate tissue fibres without cutting them, minimising trauma in lax, well-irrigated or low-density planes (subcutaneous tissue, conjunctiva, mucous membranes). The USP 5/0 (metric EP 1) gauge provides fineness and clean passage, and the 75 cm strand offers sufficient length for continuous sutures or several stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

Data verified against the official technical data sheet of the PREMISUT SEDA PRIME line (manufacturer’s catalogue).

Parameter Specification
Brand / quality PREMISUT PRIME (premium range)
Factory reference P542HR1650
Reference Cahnos (SKU) AMP542HR1650
Thread material 100% natural braided silk, coated with wax and silicone
Thread structure Braided multifilament, PRIME (non-grooved) finish
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / size USP 5/0 (metric EP 1); conforming to USP and European Pharmacopoeia
Approximate thread diameter 0.10 – 0.149 mm (USP Pharmacopoeia, non-absorbable suture)
Thread length 75 cm (single strand)
Thread colour Black identifier (high visibility in surgical field)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Atraumatic conical (taper point)
Needle size HR 16 (16 mm), Prime profile
Swaged 1 needle / 1 suture per unit
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (sterile individual sachets); minimum order 30 boxes; batch traceability
Regulatory standard Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

Reading of reference P542HR1650: P = PRIME line; 542 = 75 cm thread (541 = 45 cm); HR16 = ½ circle needle with 16 mm conical point; 50 = USP 5/0 gauge (40 = 4/0, 60 = 6/0). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

Reference P542HR1650 corresponds to the official nomenclature of the PREMISUT PRIME range (HR16 profile: ½ circle needle with 16 mm conical point, USP 5/0 gauge, 75 cm non-grooved black thread and single needle attachment). Non-absorbable coated black braided silk is one of the most traditional and standardised permanent suture families on the market (commercial types PERMA-HAND™ / MERSILK®, SILKAM®, SOFSILK™, DemeSILK™, LuxSilk®). However, after cross-checking the official catalogues of the main manufacturers and the GUDID/FDA regulatory database, no reference from another house has been found that simultaneously meets all the critical fields of this specific configuration (black braided silk, USP 5/0 gauge, 75 cm strand, ½ circle curvature, atraumatic conical point and 16 mm needle within ±1 mm tolerance): the 5/0 codes verified in other brands mostly mount ⅜ circle needles with cutting point (e.g., Ethicon MERSILK® 5/0 and B. Braun Silkam® 5/0 in DS series), or conical needles of different curvature and size, so they differ in geometry or strand length and are outside direct substitution.

There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; consult the technical department of Cahnos before use in tendering or direct substitution. The homologous families on the market that must be reviewed property by property (material, gauge, ½ circle curvature, conical point family, 16 mm needle size within ±1 mm tolerance, 75 cm strand length, black colour, single needle attachment and CE/MDR regulatory classification) before any substitution are: PERMA-HAND™ / MERSILK® (Ethicon / Johnson \u0026 Johnson MedTech), SILKAM® (B. Braun / Aesculap), SOFSILK™ (Medtronic), DemeSILK™ (DemeTECH), LuxSutures® LuxSilk and the braided silk ranges from Serag-Wiessner and Unilene. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

Tissue to suture: the HR16 conical ½ circle needle is the choice for soft, lax or well-irrigated tissues (subcutaneous tissue, mucous membranes, conjunctiva), where its atraumatic passage minimises tearing; if the plane is firm and not very distensible, consider a reverse cutting needle from the same range (e.g., HS13 profile). The USP 5/0 gauge balances fineness and strength for skin closures, ophthalmology and ligatures; for higher tension planes, the same conical needle family is available in larger gauges.

Strand length: this reference has 75 cm, optimal for continuous sutures or multiple stitches; if the procedure requires less length, the Prime family offers 45 cm formats with the same needle profile.

Similar variants in Cahnos: within the HR family (½ circle, conical point) in black silk 5/0 of 75 cm, the standard needle version of 13 mm (SKU AM542HR1350) and 20 mm (SKU AM542HR2050) are available, as well as the Prime version of 20 mm (SKU AMP542HR2050). For skin suture with reverse cutting needle in the same thread length, consult the HS range (e.g. SKU AM542HS1350), and for larger gauge planes the DS family of ¾ circle.

Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P542HR1650 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer reference

P542HR1650

Material

100% natural braided silk, coated with wax and silicone

Thread structure

Braided multifilament, PRIME (non-grooved) finish

Absorption type

Non-absorbable; gradual encapsulation, support for more than 3 months

USP size

USP 5/0 (metric EP 1)

Metric gauge (EP)

1.0

Thread diameter

0.10 – 0.149 mm

Needle shape

½ circle (1/2 circular), cylindrical body

Tip type

Atraumatic conical (taper point)

Needle size

HR16 (16 mm), Prime profile

Swaged

1 needle / 1 suture

Knotting technique

2 = 1 = 1 = 1

Finish

PRIME (non-grooved)

Sterilisation

Ethylene oxide (EO); single-use, not re-sterilisable

Presentation

Box of 12 units; minimum order 30 boxes

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HR 16

Usp

5/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “SILK Suture PREMISUT PRIME 5/0 (EP 1) Non-Absorbable · ½ Circle Conical Point Needle 16 mm (HR16 Prime) · Black Braided Thread 75 cm · Box of 12 units (Ref. P542HR1650)”

Your email address will not be published. Required fields are marked *