Description
1. Commercial Introduction
The PREMISUT PRIME SILK Suture is the precision reference of the non-absorbable range from Cahnos for the professional seeking a natural-origin thread that is manageable and has predictable clinical behaviour. This configuration (Ref. P542HR1650 · SKU AMP542HR1650) combines a 100% natural braided silk multifilament, coated with wax and silicone and with a non-grooved Prime finish, in high-visibility black, USP 5/0 (metric EP 1) gauge, with a 75 cm strand mounted on a ½ circle taper-point needle of 16 mm.
Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability and a minimum order of 30 boxes. It is the usual choice in skin surgery, ophthalmology, plastic and reconstructive surgery departments and purchasing centres looking for a permanent thread with an excellent price-quality ratio for hospital replenishment, tenders and volume contracts.
2. Technical explanation
Surgical silk is a natural protein fibre (fibroin) transformed into a braided multifilament suture, whose filaments are washed, degummed, dyed black and coated with a mixture of wax and silicone. This coating reduces capillarity and tissue drag, improves the sliding of the strand through tissue and guarantees a firm and secure knot with the recommended knotting technique 2 = 1 = 1 = 1, one of the most valued qualities of surgical silk.
Being a non-absorbable material, the thread does not degrade enzymatically: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HR16 needle of 16 mm has a ½ circle curvature with a conical point (taper point): the cylindrical body and sharp point separate tissue fibres without cutting them, minimising trauma in lax, well-irrigated or low-density planes (subcutaneous tissue, conjunctiva, mucous membranes). The USP 5/0 (metric EP 1) gauge provides fineness and clean passage, and the 75 cm strand offers sufficient length for continuous sutures or several stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified against the official technical data sheet of the PREMISUT SEDA PRIME line (manufacturer’s catalogue).
| Parameter | Specification |
| Brand / quality | PREMISUT PRIME (premium range) |
| Factory reference | P542HR1650 |
| Reference Cahnos (SKU) | AMP542HR1650 |
| Thread material | 100% natural braided silk, coated with wax and silicone |
| Thread structure | Braided multifilament, PRIME (non-grooved) finish |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / size | USP 5/0 (metric EP 1); conforming to USP and European Pharmacopoeia |
| Approximate thread diameter | 0.10 – 0.149 mm (USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (single strand) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Atraumatic conical (taper point) |
| Needle size | HR 16 (16 mm), Prime profile |
| Swaged | 1 needle / 1 suture per unit |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); minimum order 30 boxes; batch traceability |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR) |
Reading of reference P542HR1650: P = PRIME line; 542 = 75 cm thread (541 = 45 cm); HR16 = ½ circle needle with 16 mm conical point; 50 = USP 5/0 gauge (40 = 4/0, 60 = 6/0). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Reference P542HR1650 corresponds to the official nomenclature of the PREMISUT PRIME range (HR16 profile: ½ circle needle with 16 mm conical point, USP 5/0 gauge, 75 cm non-grooved black thread and single needle attachment). Non-absorbable coated black braided silk is one of the most traditional and standardised permanent suture families on the market (commercial types PERMA-HAND™ / MERSILK®, SILKAM®, SOFSILK™, DemeSILK™, LuxSilk®). However, after cross-checking the official catalogues of the main manufacturers and the GUDID/FDA regulatory database, no reference from another house has been found that simultaneously meets all the critical fields of this specific configuration (black braided silk, USP 5/0 gauge, 75 cm strand, ½ circle curvature, atraumatic conical point and 16 mm needle within ±1 mm tolerance): the 5/0 codes verified in other brands mostly mount ⅜ circle needles with cutting point (e.g., Ethicon MERSILK® 5/0 and B. Braun Silkam® 5/0 in DS series), or conical needles of different curvature and size, so they differ in geometry or strand length and are outside direct substitution.
There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; consult the technical department of Cahnos before use in tendering or direct substitution. The homologous families on the market that must be reviewed property by property (material, gauge, ½ circle curvature, conical point family, 16 mm needle size within ±1 mm tolerance, 75 cm strand length, black colour, single needle attachment and CE/MDR regulatory classification) before any substitution are: PERMA-HAND™ / MERSILK® (Ethicon / Johnson \u0026 Johnson MedTech), SILKAM® (B. Braun / Aesculap), SOFSILK™ (Medtronic), DemeSILK™ (DemeTECH), LuxSutures® LuxSilk and the braided silk ranges from Serag-Wiessner and Unilene. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
Tissue to suture: the HR16 conical ½ circle needle is the choice for soft, lax or well-irrigated tissues (subcutaneous tissue, mucous membranes, conjunctiva), where its atraumatic passage minimises tearing; if the plane is firm and not very distensible, consider a reverse cutting needle from the same range (e.g., HS13 profile). The USP 5/0 gauge balances fineness and strength for skin closures, ophthalmology and ligatures; for higher tension planes, the same conical needle family is available in larger gauges.
Strand length: this reference has 75 cm, optimal for continuous sutures or multiple stitches; if the procedure requires less length, the Prime family offers 45 cm formats with the same needle profile.
Similar variants in Cahnos: within the HR family (½ circle, conical point) in black silk 5/0 of 75 cm, the standard needle version of 13 mm (SKU AM542HR1350) and 20 mm (SKU AM542HR2050) are available, as well as the Prime version of 20 mm (SKU AMP542HR2050). For skin suture with reverse cutting needle in the same thread length, consult the HS range (e.g. SKU AM542HS1350), and for larger gauge planes the DS family of ¾ circle.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P542HR1650 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.





Reviews