We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

PREMISUT Prime Non-Absorbable Silk Suture · ½ Circle Needle Cylindrical Body Taperpoint Conical Point 16 mm (HR16) · USP 4/0 · Braided Black Thread 75 cm · Box of 12 units (Ref. P542HR1640)

Original price was: 24,90 €.Current price is: 18,90 €.

Non-absorbable suture of 100% natural braided silk, PREMISUT Prime range: black non-grooved thread, 75 cm, USP 4/0 gauge (metric EP 1.5), mounted on a ½ circle needle with cylindrical body and 16 mm Taperpoint conical point (HR16 profile). Coated with wax and silicone: reduces capillarity, favours sliding through tissue and ensures a very firm knot (2 = 1 = 1 = 1 technique), with wound support for more than three months due to gradual encapsulation. Indicated for soft tissue approximation, ligatures, ophthalmology and skin surgery. Sterilised by ethylene oxide, single-use and non-resterilisable. B2B format in a box of 12 individual sterile sachets with batch traceability and minimum order of 30 boxes. Factory ref. P542HR1640 · SKU Cahnos AMP542HR1640.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP542HR1640

Description

1. Commercial Introduction

The Silk Suture PREMISUT Prime is the reference of the premium range of non-absorbable silk from Cahnos for the professional who demands a natural-origin thread that is manageable and with predictable clinical behaviour. This configuration combines a 100% natural braided silk multifilament, coated with wax and silicone, in high-visibility black, USP gauge 4/0, mounted on a ½ circle needle with cylindrical body and Taperpoint conical tip of 16 mm (HR16 profile) and a 75 cm strand.

Sterile product, ready to use, presented in a box of 12 units in individual sachets with full batch traceability. Ideal for hospital replenishment, purchasing centres, tenders and volume contracts that seek a permanent high-performance thread, consistent sharpening from batch to batch and excellent value for money.

2. Technical Explanation

Surgical silk is a natural protein fibre —fibroin from the cocoon of Bombyx mori— presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating reduces capillarity and bacterial drag, favours the sliding of the strand through the tissue and guarantees a firm and secure knot with the recommended tying technique 2 = 1 = 1 = 1, one of the most valued qualities of surgical silk.

Being a non-absorbable material, the thread does not degrade by hydrolysis: the body encapsulates it gradually by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HR16 needle of 16 mm presents a ½ circle curvature with cylindrical body and Taperpoint conical tip: it separates and displaces tissue fibres without cutting them, minimising trauma and bleeding at the entry point, a decisive advantage in soft, lax and well-vascularised tissues, as well as in reduced surgical fields of ophthalmology and skin surgery. The USP gauge 4/0 (metric EP 1.5) balances fineness and resistance for approximation of soft tissues. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

Data verified according to the technical data sheet and instructions for use of the PREMISUT Prime range.

3.1. General characteristics

Parameter Specification
Factory reference P542HR1640 (Prime range)
Reference Cahnos (SKU) AMP542HR1640
Brand / Quality PREMISUT Prime (premium range)
Thread material 100% natural silk (Bombyx mori fibroin), braided multifilament
Thread structure Braided (multifilament), Prime non-grooved finish
Coating Wax and silicone (anti-capillarity, low tissue drag)
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / Size USP 4/0 (EP metric 1.5), in accordance with USP Pharmacopoeia and European Pharmacopoeia
Approximate thread diameter 0.150 – 0.199 mm (USP Pharmacopoeia, non-absorbable suture)
Thread length 75 cm (single strand)
Thread colour Black non-ribbed (high visibility in surgical field)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Taperpoint conical (non-cutting)
Needle size HR16 Prime (16 mm), 1 needle per thread
Swaged 1 swaged needle / 1 thread per unit
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability
Regulatory standard Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
5/0 1.0 0.10 – 0.149 mm
4/0 (this product) 1.5 0.150 – 0.199 mm
3/0 2.0 0.20 – 0.249 mm

The diameter of the strand complies with the official ranges of the USP Pharmacopoeia for non-absorbable sutures, without exceeding its limits.

3.3. Decoding the factory reference

The reference P542HR1640 is decoded as follows: P = Prime quality; 542 = black silk thread of 75 cm (541 = 45 cm); HR16 = ½ circle needle with cylindrical body and Taperpoint conical tip of 16 mm; 40 = USP gauge 4/0 (50 = 5/0, 60 = 6/0). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

3.4. PREMISUT family in silk with ½ circle Taperpoint conical point needle and black thread

Needle profile USP size Thread Reference (SKU)
HR12 Prime (taper point, 12 mm) 6/0 1 × 45 cm (black) P541HR1260 / AMP541HR1260
HR13 Prime (taper point, 13 mm) 6/0 1 × 45 cm (black) P541HR1360 / AMP541HR1360
HR13 Prime (taper point, 13 mm) 5/0 1 × 75 cm (black) P542HR1350 / AMP542HR1350
HR13 Prime (taper point, 13 mm) 4/0 1 × 75 cm (black) P542HR1340 / AMP542HR1340
HR16 Prime (taper point, 16 mm) · this product 4/0 1 × 75 cm (black) P542HR1640 / AMP542HR1640
HR16 Prime (taper point, 16 mm) 5/0 1 × 75 cm (black) P542HR1650 / AMP542HR1650
HR16 Prime (taper point, 16 mm) 6/0 1 × 45 cm (black) P541HR1660 / AMP541HR1660

4. Equivalences and Cross-References

The reference P542HR1640 corresponds to the official nomenclature of the PREMISUT Prime range (HR16 profile: ½ circle needle with cylindrical body and Taperpoint conical tip of 16 mm, USP gauge 4/0, black thread of 75 cm and single needle configuration) and Cahnos markets it without altering characters. The coated non-absorbable black braided silk is one of the most traditional and standardised natural suture families on the market.

There is no equivalence table validated by the manufacturer that cross-references this specific configuration with references from other houses; the following row is a functional comparison verified against the manufacturer’s official catalogue and authorised distribution, and does not constitute an exact reference equivalence (reserved to the same manufacturer). It must be validated against the IFU and the CE/MDR classification before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Silkam® Black – natural braided and impregnated multifilament silk, black, USP 4/0 (EP 1.5), 75 cm, HR17 needle of ½ circle, round body (taper) C0760137 / G0760137 Comparable by category (not interchangeable 1:1) Code verified in the official catalogue of B. Braun and authorised distribution: they match material (coated braided silk), gauge 4/0 (metric 1.5), black colour, length 75 cm, ½ circle curvature, round/taper body and needle size (17 mm vs 16 mm, within tolerance ±1 mm for needles ≥ 10 mm). They differ in the exact coating (wax/paraffin vs wax and silicone) and sterilisation (gamma radiation vs ethylene oxide). Confirm IFU before substituting.

This needle geometry (HR16, taper point, USP 4/0, black thread of 75 cm) is only interchangeable with full safety within the PREMISUT system itself. Other homologous families of black braided silk in the sector —Ethicon MERSILK® / PERMA-HAND™ Silk (e.g. reference W582 on a BB needle of 17 mm in ⅜ circle, which differs in curvature), Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Assusilk®, LuxSutures® LuxSilk, Serag-Wiessner, Unilene, Lorca Marín and Laboratorio Aragó— must be reviewed property by property (material, USP/metric gauge, ½ circle curvature, taper point family, needle size and length, thread length, colour, coating and CE/MDR regulatory classification) before any substitution. Consult with the technical department of Cahnos before using in tenders.

5. Selection tips and variants of interest

Tissue to suture: the USP 4/0 gauge (metric EP 1.5, diameter 0.150 – 0.199 mm) is the precision choice for soft tissue approximation, subcutaneous planes and skin surgery. The Taperpoint HR16 conical needle, 16 mm in a ½ circle, separates the fibres without cutting them, which is why it is especially recommended for lax, well-vascularised tissues of high aesthetic quality, as well as in surgical fields of ophthalmology and skin surgery.

Needle size: the 16 mm HR16 offers an intermediate reach with great rotational control in confined fields. If the protocol requires a shorter needle with the same gauge and conical point, the HR13 4/0 75 cm variant is available (SKU AMP542HR1340); if greater reach is sought while maintaining the conical point, move up to the higher profiles of the HR range.

Portfolio unification: the same HR16 Prime needle is offered in silk in 5/0 gauge, 75 cm (SKU AMP542HR1650) and 6/0, 45 cm (SKU AMP541HR1660), allowing several gauges to be covered with a single supplier and volume B2B conditions. For extreme precision needs, the HR13 Prime family covers gauges 4/0, 5/0 and 6/0.

Sterility verification: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P542HR1640 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special volume B2B conditions, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

P542HR1640

Product line

PREMISUT Prime (premium range)

Material

100% natural silk (Bombyx mori fibroin), braided multifilament

Coating

Wax and silicone

Thread structure

Braided (multifilament), Prime non-grooved finish

Absorption type

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 4/0 (metric EP 1.5)

Thread diameter

0.150 – 0.199 mm (USP Pharmacopoeia, non-absorbable suture)

Thread length

75 cm (single strand)

Thread colour

Black non-ribbed

Needle shape

½ circle (1/2 circular), cylindrical body

Tip type

Taperpoint conical (non-cutting)

Needle size

16 mm (HR16 Prime profile)

Swaged

1 needle / 1 suture per unit

Knotting technique

2 = 1 = 1 = 1

Sterilisation

Ethylene oxide (EO); single-use, not re-sterilisable

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

30 boxes

Regulatory standard

Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

Medida de aguja

HR 16

Usp

4/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “PREMISUT Prime Non-Absorbable Silk Suture · ½ Circle Needle Cylindrical Body Taperpoint Conical Point 16 mm (HR16) · USP 4/0 · Braided Black Thread 75 cm · Box of 12 units (Ref. P542HR1640)”