SEDA PREMISUT Prime 3/0 Non-Absorbable Suture · ½ Circle Cylindrical Body Taperpoint Conical Point Needle 16 mm (HR16) · Black Braided Thread 75 cm · Box of 12 units (Ref. P542HR1630)

Original price was: 24,90 €.Current price is: 18,90 €.

Non-absorbable suture of 100 % natural braided silk in PREMISUT Prime quality: black non-grooved thread of 75 cm, USP 3/0 gauge (metric EP 2), coated with wax and silicone and mounted on a ½-circle needle with cylindrical body and 16 mm Taperpoint conical point (HR16 profile). Atraumatic penetration that separates the fibres without cutting them, very secure knot (2 = 1 = 1 = 1 technique) and wound support for more than 3 months due to gradual encapsulation. Indicated for approximation of soft tissues, ligatures, ophthalmology and skin surgery. Sterilised by ethylene oxide, single-use; B2B presentation in a box of 12 individual sterile sachets with batch traceability and minimum order of 30 boxes. Factory ref. P542HR1630 · SKU AMP542HR1630.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP542HR1630

Description

1. Commercial Introduction

The Silk Suture PREMISUT Prime is the benchmark of the premium range of non-absorbable sutures from Cahnos for the professional who demands a material of natural origin, extremely manageable and with predictable clinical behaviour. This configuration combines a 100% natural braided silk strand, coated with wax and silicone, in high-visibility black, USP gauge 3/0, with a ½ circle needle with cylindrical body and 16 mm Taperpoint conical point (HR16 Prime profile) and a suture length of 75 cm.

Sterile product, ready to use, presented in a box of 12 units in individual sachets with full batch traceability. It is the usual choice in operating theatres, ophthalmology services, skin surgery, general soft tissue surgery, ligatures and B2B purchasing centres that need a permanent suture of high performance, batch-to-batch consistency and excellent value for money for hospital replenishment, tenders and volume contracts.

2. Technical Explanation

Surgical silk is a natural protein fibre (fibroin from the cocoon of Bombyx mori) processed to remove natural waxes and gums and presented in a braided multifilament construction. In the Prime finish, the suture is offered with a non-grooved surface and a wax and silicone coating, which reduces capillarity and bacterial wicking, favours the sliding of the strand through the tissue and guarantees a firm and secure knot with the recommended knotting technique 2 = 1 = 1 = 1.

Being a non-absorbable material, the suture does not degrade by hydrolysis: the body gradually encapsulates it with connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The 16 mm HR16 needle has a ½ circle curvature with a cylindrical body and conical point (Taperpoint): the point separates and displaces the tissue fibres without cutting them, minimising trauma and bleeding at the entry point, a decisive advantage in soft, lax and well-vascularised tissues, as well as in reduced surgical fields in ophthalmology and skin surgery. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / quality PREMISUT Prime (premium range, non-grooved)
Factory reference P542HR1630
Reference Cahnos (SKU) AMP542HR1630
Thread material 100 % natural silk (fibroin from Bombyx mori), braided multifilament
Thread structure Braided (multifilament), Prime non-grooved finish
Coating Wax and silicone (anti-capillarity, low tissue drag)
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / size USP 3/0 (metric EP 2)
Approximate thread diameter 0.20 – 0.249 mm (USP, non-absorbable suture)
Thread length 75 cm (single strand)
Thread colour Black identifier (high visibility in surgical field)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Taperpoint conical (non-cutting)
Needle size HR 16 Prime (16 mm), 1 needle per suture
Swaged 1 swaged needle / 1 thread per unit
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability
Regulatory standard Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
3/0 (this product) 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm
4/0 1.5 0.15 – 0.199 mm
5/0 1 0.10 – 0.149 mm

The strand diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without extending their limits.

3.3. Decoding the factory reference

The reference P542HR1630 is decoded as follows: P = Prime quality (non-grooved suture with reinforced batch traceability); 542 = black silk suture of 75 cm (541 = 45 cm); HR16 = ½ circle needle with cylindrical body and 16 mm Taperpoint conical point; 30 = USP gauge 3/0 (20 = 2/0, 50 = 5/0, 60 = 6/0). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

3.4. Family PREMISUT SILK Prime with HR16 needle with Taperpoint conical point and black suture

Needle profile USP size Thread Reference (SKU)
HR16 Prime 3/0 1 × 75 cm (black) P542HR1630 / AMP542HR1630 (this product)
HR16 Prime 2/0 1 × 75 cm (black) P542HR1620 / AMP542HR1620
HR16 Prime 5/0 1 × 75 cm (black) P542HR1650 / AMP542HR1650
HR16 Prime 6/0 1 × 45 cm (black) P541HR1660 / AMP541HR1660

4. Equivalences and Cross-References

The reference P542HR1630 corresponds to the official nomenclature of the PREMISUT Prime range (HR16 profile: ½ circle needle with cylindrical body and 16 mm Taperpoint conical point, USP gauge 3/0, black non-grooved suture of 75 cm and assembly of 1 needle per suture). Black non-absorbable braided silk with a round-bodied needle and conical point in ½ circle is one of the most standardised natural suture families on the market, with homologous lines in B. Braun / Aesculap SILKAM® Black, Ethicon (Johnson \u0026 Johnson MedTech) MERSILK™ / PERMA-HAND™ Silk, Medtronic Sofsilk™, DemeTECH DemeSILK™, as well as the braided silk ranges from Assut, Unilene, Serag-Wiessner and Laboratorio Aragó.

After comparing the official catalogues of the main manufacturers and the regulatory basis (GUDID/FDA) for this specific configuration (black braided silk, ½ circle curvature, 16 mm Taperpoint conical point within ±1 mm tolerance, USP gauge 3/0 and 75 cm strand), no reference from another house has been found that simultaneously meets all the critical fields: the 3/0 75 cm homologues verified in other brands mount conical needles of a different size (e.g. HR20 needle configurations or higher, outside the ±1 mm tolerance versus the HR16) or trocar point geometries, so they differ in size, curvature or point family and fall outside direct substitution. The homologous families cited must be reviewed property by property (material, coating, gauge, ½ circle curvature, Taperpoint point family and size, 75 cm strand length, black colour, 1 needle assembly and CE/MDR regulatory classification) in the technical data sheet or IFU of the alternative manufacturer before any substitution. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference; no unverified cross-reference codes are published.

There is no manufacturer-validated equivalence table that cross-references this specific configuration (black braided silk, 16 mm HR16 needle in ½ circle with Taperpoint conical point, USP gauge 3/0 and 75 cm strand) with references from other houses; consult the technical department of Cahnos before use in tendering or direct substitution. This needle geometry is only fully safely interchangeable within the PREMISUT system itself, verifying reference by reference in the official catalogue.

5. Selection tips and variants of interest

Tissue to suture: the USP 3/0 gauge (metric EP 2, diameter 0.20 – 0.249 mm) offers the optimal balance between fineness and strength for approximating soft tissues under low-to-medium tension: skin, subcutaneous tissue, mucous membranes, ligation of small-calibre vessels and precision surgery such as ophthalmology. The Taperpoint HR16 conical needle, 16 mm in a ½ circle, separates the fibres without cutting them, and is therefore especially recommended for lax, well-vascularised tissues with high aesthetic requirements; for firm, non-distensible planes, consider the reverse-cutting profiles in the same PREMISUT range (HS family).

Variants within the Cahnos catalogue:

Variant / Reference Description
AMP542HR1620 (P542HR1620) SEDA Prime HR16 – 2/0 black – 75 cm (same needle and length, larger gauge)
AMP542HR1650 (P542HR1650) SEDA Prime HR16 – 5/0 black – 75 cm (same needle and length, finer gauge)
AMP541HR1660 (P541HR1660) SEDA Prime HR16 – 6/0 black – 45 cm (same needle, microsurgery gauge and short thread)
AMP542HR2050 (P542HR2050) SEDA Prime HR20 – 5/0 black – 75 cm (same conical point, longer-reach needle)
AMP542HR2630 (P542HR2630) SEDA Prime HR26 – 3/0 black – 75 cm (same gauge, long needle for deep planes)

Sterility and storage: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep reference P542HR1630 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

100% natural silk (Bombyx mori fibroin), braided multifilament

Structure

Braided, Prime non-grooved finish

Coating

Wax and silicone (anti-capillarity, low tissue drag)

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

Gauge

USP 3/0 (metric EP 2)

Thread diameter

0.20 – 0.249 mm (USP)

Needle shape

½ circle (1/2 circular), cylindrical body

Tip type

Taperpoint conical (non-cutting)

Needle size

HR16 (16 mm)

Swaged

1 swaged needle / 1 suture

Knotting technique

2 = 1 = 1 = 1

Sterilisation

Ethylene oxide (EO); sterile, single-use, non-resterilisable

Presentation

Box of 12 units (individual sterile sachets); minimum order 30 boxes

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Manufacturer reference

P542HR1630

Regulatory standard

Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HR 16

Usp

3/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “SEDA PREMISUT Prime 3/0 Non-Absorbable Suture · ½ Circle Cylindrical Body Taperpoint Conical Point Needle 16 mm (HR16) · Black Braided Thread 75 cm · Box of 12 units (Ref. P542HR1630)”