Polyester suture Premisut Prime USP 0 non-absorbable – 3/8 circle reverse cutting triangular needle (DS 36 mm), green thread 75 cm, silicone coated | Ref. AMP852DS3610

Original price was: 38,56 €.Current price is: 28,30 €.

Non-absorbable braided multifilament polyester suture, Premisut Prime line, with ⅜ circle 36 mm reverse cutting triangular point needle (DS 36), USP 0 gauge, green thread 75 cm and silicone coating. Non-absorbable, with gradual encapsulation and high tensile strength that maintains wound support for more than three months. Sterilised by ethylene oxide and indicated for soft tissue approximation, ligatures, ophthalmology and neurosurgery. Factory reference P852DS3610; presentation in box of 12 units with minimum order of 30 boxes. Available for purchasing centres and operating theatre services.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP852DS3610

Description

1. Product Presentation

The Premisut Prime polyester suture is the reference choice for general surgery, ophthalmology, neurosurgery and purchasing centres looking for a high-strength permanent thread with predictable clinical behaviour. This reference combines a silicone-coated braided multifilament, USP 0 gauge, green thread 75 cm and a ⅜ circle 36 mm needle with reverse cutting triangular point (DS 36).

Its Prime quality ensures a regular surface, smooth passage through tissue and excellent knot retention, providing prolonged mechanical support during healing. Sterile product, ready to use, supplied in a box of 12 units.

2. Technical explanation

Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer with a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates thread glide through tissues and minimises the saw effect, improving handling without compromising knot retention.

As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase. The ⅜ circle 36 mm needle with reverse cutting triangular point (reverse cutting) is designed to precisely penetrate firm, inelastic tissues, cutting the tissue plane without tearing, making it especially useful in ophthalmic surgery, microsurgery and approximation of planes with reduced working fields. The green colour ensures optimal visibility of the thread on the surgical field.

3. Technical Specifications

Material Braided multifilament polyester coated with silicone (polyethylene terephthalate / polyester – polyethylene)
Structure Braided multifilament, non-grooved surface
Absorption Non-absorbable, with gradual encapsulation
Gauge USP 0 (metric 3.5)
Thread length 75 cm
Needle ⅜ circular, triangular point, reverse cutting
Needle size DS 36 (36 mm)
Colour Green (identification standard; optional white)
Sterilisation Ethylene oxide
Quality Prime (Premisut)
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference AMP852DS3610 (factory equivalent P852DS3610)

4. Equivalences and Cross-References

Non-absorbable braided polyester is the most widespread permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical behaviour, this Premisut Prime suture is comparable by category (not interchangeable 1:1) with the main commercial ranges of braided polyester:

Manufacturer / Brand Family / Model Reference code Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) ETHIBOND EXCEL (coated braided polyester) EH7688H (USP 0, green, 75 cm, reverse cutting needle 30 mm, ⅜ circle); X538H (USP 1, reverse cutting 36 mm, ½ circle) Comparable by category, not interchangeable 1:1 Polybutylate coating (not silicone); needle of 30 mm or ½ circle geometry depending on code, not DS 36 reverse cutting
B. Braun PremiCron (braided and silicone-coated) C0026017 (green, USP 0, 75 cm, HR26 needle); C0026067 (green, USP 0, 75 cm, HR37s needle) Comparable by category, not interchangeable 1:1 Same material, silicone coating and gauge; HR cardiovascular curved needles (½ circle), not DS 36 reverse cutting
Medtronic (Covidien) Surgidac / Ti-Cron (braided polyester) D / CD / ED code series (consult official catalogue by gauge and needle) Comparable by category, not interchangeable 1:1 Same base material; Surgidac uncoated and Ti-Cron with silicone; needle geometries different from DS 36
Teleflex (Deknatel) Tevdek II (PTFE-coated braided polyester) 7-555 (green, USP 0, 75 cm, ⅜ circle reverse cutting needle 24 mm, box of 36) Comparable by category, not interchangeable 1:1 PTFE coating (not silicone); 24 mm needle versus the 36 mm of the DS 36; presentation in box of 36 units

Important note: there is no equivalence table validated by the manufacturer that cross-references these brands with the DS 36 ⅜ circle reverse cutting needle configuration; the cited references have been verified in official catalogues or from authorised distributors for material and gauge, but with different needle geometry. The DS 36 needle is only interchangeable within the Premisut system itself. Before using them in tenders or direct substitution, consult the technical department of Cahnos and verify the manufacturer’s technical data sheet and IFU.

5. Selection tips and variants of interest

Select the gauge according to the tissue and the tension the suture must withstand: USP 0 is suitable for planes with medium-high mechanical demand and ligatures; consider finer gauges (USP 2/0, 3/0) for subcutaneous tissue and precision ophthalmic surgery, and USP 1 for planes under higher tension.

Within the Cahnos catalogue you will find variants of the same Prime family with reverse cutting needle: AMP852DS3010 (USP 0, DS 30), AMP852DS3020 (USP 2/0, DS 30) and AMP852DS3001 (USP 1, DS 30), as well as fine gauges with DS 16 needle (AMP852DS1630, AMP852DS1640 and AMP852DS1650). If your purchasing centre requires a standard profile, the reference AM852DS3610 maintains the same configuration with conventional quality control. For other thread structures with the same needle, you have the monofilament polypropylene version AMP732DS3610 and the absorbable PGA version AMP112DS3610. The standard presentation is the box of 12 units with a minimum order of 30 boxes; for larger volumes or supply agreements, contact the commercial department of Cahnos.

Additional information

Material

Braided multifilament polyester (polyethylene terephthalate / polyester – polyethylene)

Structure

Braided multifilament, non-grooved surface

Coating

Silicone (optimal sliding and handling)

Absorption

Non-absorbable – gradual encapsulation, support > 3 months

Metric gauge (EP)

3.5

Needle

⅜ circle, reverse cutting triangular point (reverse cutting)

Needle size

DS 36 (36 mm)

Colour

Green (white optional)

Sterilisation

Ethylene oxide

Quality

Prime (Premisut)

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P852DS3610

Medida de aguja

DS 36

Usp

0

Color

Green, White

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Polyester suture Premisut Prime USP 0 non-absorbable – 3/8 circle reverse cutting triangular needle (DS 36 mm), green thread 75 cm, silicone coated | Ref. AMP852DS3610”

Your email address will not be published. Required fields are marked *