Non-Absorbable SILK Suture PREMISUT · ½ Circle Needle Taperpoint Conical Point HR20 (20 mm) · USP 5/0 (Metric EP 1) · Black Braided Thread 75 cm · Box of 12 units (Ref. 542HR2050 · SKU AM542HR2050)

Original price was: 19,90 €.Current price is: 12,70 €.

Non-absorbable surgical suture of 100% natural braided silk from the PREMISUT range: 75 cm black grooved thread in USP 5/0 (metric EP 1), coated with wax and silicone for low capillarity and smooth sliding. It mounts a ½-circle needle with cylindrical body and 20 mm Taperpoint conical point (HR20 profile), atraumatic penetration ideal for soft tissue approximation, ligatures, ophthalmology and skin surgery. Very firm knot (technique 2 = 1 = 1 = 1) and wound support for more than 3 months. Sterilised by ethylene oxide, single-use. Factory ref. 542HR2050 · Price per box of 12 units in individual sterile sachets. Ref. AM542HR2050.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM542HR2050

Description

1. Commercial Introduction

The SILK SUTURE PREMISUT 1/2 Cylindrical HR20 (factory ref. 542HR2050 · SKU Cahnos AM542HR2050) combines the clinical tradition of natural silk thread with modern braiding and coating, offering a reliable solution with exceptional handling and secure knotting for the approximation of soft tissues. Each unit mounts a ½-circle needle with a cylindrical body and a 20 mm Taperpoint conical point (HR20 profile), the reference geometry for atraumatic penetration in reduced to medium access fields.

It is the usual choice in ophthalmology departments, skin surgery, minor surgery and ligatures, as well as in purchasing centres and B2B tenders: sterile, ready-to-use product, presented in a box of 12 units in individual sachets, with complete batch traceability. The standard quality of the PREMISUT range offers the best balance between clinical performance and acquisition cost for continuous replacement in the operating theatre.

2. Technical explanation of the material and procedure

Surgical silk is a natural protein fibre —fibroin from the cocoon of Bombyx mori— processed to remove natural waxes and gums and presented in a braided multifilament construction, coated with a mixture of wax and silicone. This coating reduces the capillarity of the multifilament and the friction when passing through tissue, improves handling and favours knot seating with the recommended tying technique 2 = 1 = 1 = 1, one of the most valued qualities of surgical silk.

As a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The 20 mm HR20 needle features a ½-circle curvature with a cylindrical body and conical point (Taperpoint): the point separates tissue fibres without cutting them, achieving atraumatic penetration with minimal trauma to the puncture bed, ideal for soft, lax and well-vascularised tissues. The fluted black colour ensures optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Factory reference 542HR2050
Reference Cahnos (SKU) AM542HR2050
Brand / quality PREMISUT (standard range)
Thread material 100 % natural silk (fibroin from Bombyx mori), multifilament
Thread structure Braided (multifilament), fluted surface
Coating Wax and silicone (anti-capillarity, low tissue drag)
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 5/0 (metric EP 1); conforming to USP and European Pharmacopoeia
Approximate thread diameter 0.10 – 0.149 mm (USP Pharmacopoeia, non-absorbable suture)
Thread length 75 cm (single strand, no loop)
Thread colour Fluted black (high visibility on the surgical field)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Conical (Taperpoint), non-cutting
Needle size HR20 (20 mm), 1 needle per thread
Swaged 1 needle / 1 thread of 75 cm per unit
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (individual sterile sachets)
Regulatory standard Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
5/0 (this product) 1 0.10 – 0.149 mm
4/0 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.

3.3. PREMISUT Silk family with HR20 needle (½ circle, cylindrical body, conical point, black thread 75 cm)

USP size Quality Thread Reference (SKU)
5/0 Normal 1 × 75 cm (black) 542HR2050 / AM542HR2050 (this product)
5/0 Prime 1 × 75 cm (black) P542HR2050 / AMP542HR2050
4/0 Normal 1 × 75 cm (black) 542HR2040 / AM542HR2040
3/0 Normal 1 × 75 cm (black) 542HR2030 / AM542HR2030
2/0 Normal 1 × 75 cm (black) 542HR2020 / AM542HR2020
0 Normal 1 × 75 cm (black) 542HR2010 / AM542HR2010

Decoding of reference 542HR2050: 542 (black silk thread, 75 cm) + HR (½-circle needle with cylindrical body and conical point) + 20 (20 mm) + 50 (USP 5/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

Reference 542HR2050 corresponds to the official nomenclature of the PREMISUT range (HR20 profile: 20 mm ½-circle Taperpoint conical-point needle, USP 5/0 gauge, 75 cm fluted black thread, single-strand configuration). This needle geometry is only fully safely interchangeable within the PREMISUT system itself: the Prime range variant with identical configuration (Ref. P542HR2050 · SKU AMP542HR2050) is the direct equivalent within the same manufacturer.

Black non-absorbable braided silk is one of the most standardised natural suture families on the market. The cross-reference detailed below respects the configuration property by property (material, gauge, curvature, point family, needle size, length and number of threads, colour, configuration and presentation); as it is another brand, it does not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU and CE/MDR classification before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
LuxSutures® (Corza Medical) LuxSilk® – non-absorbable black braided silk SI50HR20 – LuxSilk 5/0, black, 75 cm, HR20 ½-circle conical-point needle (verified in authorised distribution technical data sheet) Comparable by category (not interchangeable 1:1) Closest technical match located: same material (braided silk), USP 5/0 gauge (EP 1), black colour, length 75 cm, configuration of 1 needle per thread, ½-circle needle with round body and 20 mm conical point (HR20) and box of 12 units. The exact coating formulation, the manufacturer and their own regulatory classification differ; confirm IFU and CE/MDR marking before substituting.

There is no manufacturer-validated equivalence table cross-referencing this specific configuration (black braided silk, 20 mm HR20 needle in ½-circle with conical point, USP 5/0 gauge and 75 cm thread) with codes from other commercial houses; consult the Cahnos technical department before using in tendering or direct substitution, always verifying property by property (material, gauge, curvature, point family, needle length, number and length of threads, colour, coating and CE/MDR regulatory classification) in the alternative manufacturer’s technical data sheet or IFU. Verified against the official B. Braun catalogue, the closest SILKAM® Black with conical point in USP 5/0 and 75 cm mounts an HR17 17 mm needle (ref. C0760129), outside the ±1 mm tolerance compared to the 20 mm HR20 of this data sheet, so it is not published as a cross-reference; the SILKAM® configuration with HR20 needle is marketed in larger gauges. Other homologous market families that should be reviewed before any substitution are MERSILK® / PERMA-HAND™ Silk (Ethicon), Silkam® (B. Braun/Aesculap), Sofsilk™ (Medtronic), DemeSILK™ (DemeTECH), LOOK™ Silk (Corza Medical) and the braided silk ranges from Assut, Serag-Wiessner and Unilene. The brands cited belong to their respective manufacturers and are mentioned only as a category reference.

5. Selection tips and variants of interest

Tissue to be sutured: USP 5/0 gauge (metric EP 1) is the classic choice for fine and low-tension tissues: skin, subcutaneous tissue, mucous membranes, precision closures and ophthalmology procedures, always with a conical-point needle to minimise tissue damage in lax and well-vascularised tissues.

Needle length: the HR20 profile of 20 mm covers reduced to medium access fields. For smaller accesses in the same gauge 5/0, the HR16 profile (Ref. 542HR1650 · SKU AM542HR1650) and the HR13 (SKU AM542HR1350) are available; for larger reach fields, the HR24 (AM542HR2430), HR26 (AM542HR2630) and HR30 (AM542HR3030) profiles of the same Silk PREMISUT family, all with conical point.

Gauge variants on the same HR20 needle: the range offers the same profile in USP 4/0 (AM542HR2040), 3/0 (AM542HR2030), 2/0 (AM542HR2020) and 0 (AM542HR2010), all with 75 cm black thread, allowing a single supplier across the entire family. Prime quality: if you need maximum sharpness consistency and batch-to-batch traceability, the same configuration is available in the Prime range (Ref. P542HR2050 · SKU AMP542HR2050).

Sterility and storage: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep reference 542HR2050 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer reference

542HR2050

Product line

PREMISUT (standard range)

Material

100 % natural silk (Bombyx mori fibroin), multifilament

Structure

Braided (multifilament), fluted surface

Coating

Wax and silicone (anti-capillarity, low tissue drag)

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 5/0 (metric EP 1)

Metric gauge (EP)

1

Thread diameter

0.10 – 0.149 mm

Suture colour

Fluted black

Needle shape

½ circle (1/2 circular), cylindrical body

Tip type

Conical (Taperpoint), non-cutting

Needle size

HR20 (20 mm)

Swaged

1 needle / 1 thread of 75 cm per unit

Knotting technique

2 = 1 = 1 = 1

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units (individual sterile sachets)

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HR 20

Usp

5/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal