NYLON Suture PREMISUT Prime · ½ Circle Cylindrical Taperpoint Conical Point Needle 20 mm (HR20) · USP 3/0 (EP 2) · Black Monofilament Thread 75 cm · Non-Absorbable Polyamide · Box of 12 units (Ref. P642HR2030 · SKU AMP642HR2030)

13,83 €

Non-absorbable monofilament nylon suture (polyamide 6 or 6.6) from the PREMISUT Prime range, in USP 3/0 gauge (metric EP 2), high-visibility black colour and 75 cm grooved strand without coating. It mounts a Prime needle of ½ circle, cylindrical body and 20 mm taperpoint conical point (HR20 profile): atraumatic passage through soft tissues, minimal tissue reaction and excellent knot retention, with wound support for more than 3 months. Indicated for soft tissue approximation, ligatures, ophthalmology and neurosurgery. Sterile by ethylene oxide, single-use, in a box of 12 individual sachets with batch traceability. Factory ref. P642HR2030 · SKU AMP642HR2030.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP642HR2030

Description

1. Commercial Introduction

The NYLON PREMISUT Prime Suture (factory reference P642HR2030 · SKU Cahnos AMP642HR2030) is the premium reference from Cahnos among non-absorbable nylon sutures for procedures requiring a permanent, manageable, high-performance thread. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black colour, USP 3/0 gauge (metric EP 2) and a 75 cm uncoated strand, mounted on a Prime ½ circle needle with a 20 mm taperpoint conical tip (HR20 profile).

It is a common choice in ophthalmology, neurosurgery, general surgery and purchasing departments that value batch-to-batch consistency and full traceability of the Prime range. Sterile product, ready to use, presented in a box of 12 individual sterile pouches.

2. Technical Explanation

Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and maintains high tensile strength for more than three months, amply covering the critical phase of wound healing. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared to multifilaments, and minimises the inflammatory reaction.

Its grooved finish improves knot grip and handling in the surgical field, while the black colour ensures optimal contrast on the field, especially in precision specialties. The 20 mm HR20 Prime needle features a ½ circle curvature with a cylindrical body and conical tip (taperpoint): the sharp tip without cutting edges penetrates tissues by separating fibres without cutting them, making it especially suitable for fascias, peritoneum, muscle, conjunctiva and other soft, well-vascularised tissues where minimising trauma is sought. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical specifications and tables

3.1. General characteristics

Parameter Specification
Factory reference P642HR2030
Reference Cahnos (SKU) AMP642HR2030
Brand / Quality PREMISUT Prime (premium range)
Thread material Nylon monofilament (polyamide 6 or 6.6), uncoated
Thread structure Monofilament with grooved surface
Coating None
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / Size USP 3/0 (metric EP 2), in accordance with USP and European Pharmacopoeia gauges.
Approximate thread diameter 0.20 – 0.249 mm
Thread length 75 cm (single strand, no loop)
Thread colour Black identifier (high visibility in surgical field)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Conical / Taperpoint, grooved
Needle size HR 20 Prime (20 mm)
Configuration 1 needle per suture; 1 suture of 75 cm per pack
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Commercial presentation Box of 12 sterile individual sachets; batch traceability
Regulatory standard Complies with USP/EP Pharmacopoeia; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
4/0 1.5 0.15 – 0.199 mm
3/0 (this product) 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm

The thread diameter complies with the official ranges of the USP Pharmacopoeia for non-absorbable sutures, without exceeding its limits.

3.3. PREMISUT Prime family in nylon — ½ circle needle of 20 mm, taperpoint conical tip, black thread

Needle size USP EP Colour Suture size Reference
HR 20 Prime 5/0 1 Black 75 cm P642HR2050 (AMP642HR2050)
HR 20 Prime 4/0 1.5 Black 75 cm P642HR2040 (AMP642HR2040)
HR 20 Prime 3/0 2 Black 75 cm P642HR2030 (AMP642HR2030) — this product
HR 20 Prime 3/0 2 Black 2×75 cm P642HR2030.2 (AMP642HR2030.2)
HR 20 Prime 2/0 3 Black 75 cm P642HR2020 (AMP642HR2020)
HR 20 Prime 2/0 3 Black 2×75 cm P642HR2020.2 (AMP642HR2020.2)

The same Prime conical needle is available in longer travel profiles (HR26, HR30, HR37 and HR40) and in USP gauges 6/0, 5/0, 4/0, 3/0, 2/0, 0 and 1 depending on the tissue plane to be sutured.

4. Equivalences and Cross-References

The reference P642HR2030 corresponds to the official nomenclature of the PREMISUT Prime range (HR20 profile: ½ circle needle with 20 mm taperpoint conical tip, USP 3/0 gauge, black grooved thread of 75 cm in a single strand) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or bidding.

Non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type «Ethilon»). There is no manufacturer-validated equivalence table that cross-references this specific configuration (½ circle needle with 20 mm conical tip, USP 3/0, black, 75 cm) with references from other houses; matches must be treated as functional comparisons at category level, not interchangeable 1:1 without prior technical validation.

As a guide, references from the same nylon monofilament family have been cross-checked in official catalogues which, despite matching in material, gauge (USP 3/0 / EP 2) and thread length (75 cm), differ in at least one critical field (curvature, tip family, needle length or colour) and therefore cannot be listed as 1:1 equivalents: ETHILON® 3-0 black 75 cm with PS-1 needle (Ethicon, code EH7563H, ⅜ circle reverse cutting needle of 24 mm) and DAFILON® blue 3/0 (EP 2) 75 cm DS24 (B. Braun / Aesculap, code C0935352, ⅜ circle reverse cutting needle of 24 mm). In both cases, the IFU and CE/MDR classification must be confirmed before any substitution.

Homologous families of non-absorbable nylon monofilament that must be reviewed property by property (material, gauge, curvature, tip family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution are: ETHILON® (Ethicon / Johnson \u0026 Johnson MedTech), DAFILON® (B. Braun / Aesculap), MONOSOF™ and DERMALON™ (Medtronic / Covidien), DEMELON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these houses have been verified in public sources for the exact HR20 configuration of 20 mm, USP 3/0, conical tip and black 75 cm strand; they must be confirmed with the manufacturer before use in substitution or tendering.

There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (HR20 Prime, USP 3/0, black 75 cm thread) is only fully safely interchangeable within the PREMISUT system itself: the standard-range variant of identical configuration is Ref. 642HR2030 (SKU AM642HR2030) and the double-strand version is Ref. P642HR2030.2 (SKU AMP642HR2030.2). The cited brands belong to their respective manufacturers and are mentioned solely as an equivalence reference.

5. Selection tips and variants of interest

Tissue to suture: the USP 3/0 gauge (metric EP 2) offers the optimal balance between fineness and strength for subcutaneous tissue, skin, mucous membranes, soft tissues with low-medium tension and ligatures, always with a conical point needle to minimise tissue damage. For finer planes, consider USP 4/0 (Ref. AMP642HR2040) or 5/0 (Ref. AMP642HR2050) with the same Prime needle; for higher loads, USP 2/0 (Ref. AMP642HR2020) or USP 0.

Needle length: the 20 mm HR20 profile is the ideal option for surgical fields with very limited access (ophthalmology, minor surgery, paediatric surgery and neurosurgery). For medium-depth access, the HR26 (Ref. AMP642HR2630), HR30, HR37 and HR40 profiles are available from the same Prime range.

Alternative point: if the protocol requires a reverse cutting needle for skin or mucous membranes, the same gauge and length is available in the HS26 family (Ref. AMP642HS2630), always with prior validation of the technical data sheet.

Double-thread presentation: for continuous sutures or high-consumption programmes, the same needle and gauge is offered in a 2×75 cm presentation (Ref. AMP642HR2030.2).

Prime vs. standard quality: the Prime range provides maximum sharpening precision and batch-to-batch consistency; if unit cost is critical, the standard range (Ref. AM642HR2030) maintains the same dimensional specifications with standard sharpening.

Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642HR2030 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Product line

PREMISUT Prime

Manufacturer reference

P642HR2030

Material

Nylon monofilament (polyamide 6 or 6.6), uncoated

Structure

Monofilament with grooved surface

Coating

None

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 3/0 (metric EP 2)

Metric gauge (EP)

2

Thread diameter

0.20 – 0.249 mm

Thread length

75 cm (1 strand)

Needle shape

1/2 circle (½ circular), cylindrical body

Tip type

Conical / Taperpoint, grooved

Needle size

HR 20 Prime (20 mm)

Configuration

1 needle per unit, single strand

Sterilisation

Ethylene oxide (EO)

Use

Single-use, sterile. Do not re-sterilise

Presentation

Box of 12 sterile individual sachets

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Regulatory standard

Complies with USP/EP Pharmacopoeia; CE marking (MDR)

Swaged

1 needle per suture

Medida de aguja

HR 20

Usp

3/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime