Description
1. Commercial Introduction
The NYLON PREMISUT Prime 1/2 Cylindrical HR50 mm – USP 1 – Black – 90 cm Suture (Ref. P643HR5001 · SKU AMP643HR5001) is the premium reference in Cahnos’s range of non-absorbable sutures for procedures requiring maximum sharpness precision and batch-to-batch consistency. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black, USP 1 gauge and 90 cm of fluted thread, mounted on a Prime ½ circle needle with cylindrical body and conical point (taperpoint) of 50 mm (HR50 profile). It is a common choice in ophthalmology, neurosurgery, general surgery departments and purchasing centres that need a high-performance permanent thread with predictable clinical behaviour and full traceability. Sterile product, ready to use, presented in a box of 12 units in individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The fluted finish of the strand improves knot retention and handling.
The 50 mm HR50 Prime needle features a ½ circle curvature with cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fasciae, peritoneum, muscle, conjunctiva) where minimising trauma is sought. Prime quality ensures more consistent sharpening and more predictable penetration at every stitch. USP 1 gauge (EP metric 4) provides high tensile strength for tissues under medium-high tension, and the 90 cm thread offers sufficient length for continuous sutures or multiple stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.40 – 0.499 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 90 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / cylindrical (Taperpoint) |
| Needle size | HR 50 Prime (50 mm) |
| Configuration | 1 needle per unit, 1 suture of 90 cm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and general surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P643HR5001 |
| Reference Cahnos (SKU) | AMP643HR5001 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
3.3. PREMISUT HR50 family (½ circle needle, 50 mm, conical point (taperpoint), black thread)
| Needle profile | USP size | Thread | Reference |
| HR 50 Prime | 1 | 1 × 90 cm (black) | P643HR5001 / AMP643HR5001 (this product) |
| HR 50 | 1 | 1 × 90 cm (black, standard range) | 643HR5001 / AM643HR5001 |
| HR 50 Prime | 1 | 1 × 150 cm loop (black, Loop) | P645HR50L01 / AMP645HR50L01 |
| HR 50 Prime | 0 | 1 × 150 cm loop (black, Loop) | P645HR50L10 / AMP645HR50L10 |
The same HR50 needle is available with 75 cm thread (series 642) and, within the ½ circle conical needle family, in shorter profiles such as HR30 (30 mm) and HR40 (40 mm) for procedures with shorter runs.
4. Equivalences and Cross-References
Reference P643HR5001 corresponds to the official nomenclature of the PREMISUT Prime range (HR50 profile: ½ circle conical point needle of 50 mm, USP 1 gauge, black fluted 90 cm thread) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this product with other brands for the exact combination of USP 1 + ½ circle taperpoint needle of 50 mm + black 90 cm strand; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, USP 1, 75 cm thread, CTX needle of 48 mm (½ circle, conical point) | 830H (verified in GUDID/FDA and official Ethicon catalogue) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP 1 gauge (EP 4), black colour, ½ circle curvature and conical point family; they differ in needle size (CTX 48 mm vs HR50 50 mm, outside the ±1 mm tolerance) and thread length (75 cm vs 90 cm). Confirm IFU and CE/MDR classification before substituting. |
| Medtronic / Covidien | Monosof™ – black nylon monofilament, USP 1, 100 cm thread (40″), GS-25 needle of 48 mm (½ circle, conical point) | CN724 (verified in official Medtronic catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6.6), USP 1 gauge, black colour, ½ circle curvature and conical point family; they differ in needle size (GS-25 48 mm vs HR50 50 mm, outside the ±1 mm tolerance) and thread length (100 cm vs 90 cm). Confirm IFU and CE/MDR classification before substituting. |
| DemeTECH | DemeLON™ – black nylon monofilament, USP 1, 75 cm thread, DCTX needle of 48 mm (½ circle, round body, conical point) | NL260148B0P (verified in official DemeTECH store and authorised distributor) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6), USP 1 gauge, black colour, ½ circle curvature and conical point family; they differ in needle size (DCTX 48 mm vs HR50 50 mm, outside the ±1 mm tolerance) and thread length (75 cm vs 90 cm). Confirm IFU and CE/MDR classification before substituting. |
Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: DAFILON® (B. Braun, black polyamide 6.6), DERMALON™ (Medtronic), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these manufacturers have been verified in public sources for the exact HR50 configuration of 50 mm, USP 1 and black 90 cm strand; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no equivalence table validated by the manufacturer for this configuration; check the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) in the technical data sheet or instructions for use of the alternative manufacturer before using this information in tenders or direct substitution. This needle geometry (HR50 Prime, USP 1, 90 cm) can only be safely interchanged within the PREMISUT system itself. Consult Cahnos’s technical department to validate any equivalence.
5. Selection tips and variants of interest
Tissue to be sutured: USP 1 (EP 4) gauge offers high tensile strength for subcutaneous tissue, fasciae, aponeuroses and soft tissues under high tension, always with a conical-point needle to minimise tissue damage. For finer planes, consider USP 0 or USP 2/0 from the same Prime family.
Needle length: the 50 mm HR50 profile covers medium-depth access. For smaller fields, the HR30 and HR40 families from the same Prime range are available (e.g. HR40 in USP 1 with 75 cm thread, Ref. AMP642HR4001, or HR30 in USP 1 with 75 cm thread, Ref. AMP642HR3001).
Thread length and presentation: this reference is 1 × 90 cm (P643 series). The 150 cm loop version (Ref. P645HR50L01 / AMP645HR50L01) is practical for ligatures and deep-field surgery without re-threading; the loop version in USP 0 gauge is available under Ref. P645HR50L10 / AMP645HR50L10.
Prime quality: if the procedure requires maximum sharpness precision and batch-to-batch consistency, the Prime range offers this same geometry and gauge; if the cost per unit is a critical factor, the standard range (Ref. 643HR5001 / AM643HR5001) maintains the same dimensional specifications with standard sharpening performance.
Sterility verification: product sterilised by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P643HR5001 and batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact Cahnos’s technical-commercial team.





Reviews
There are no reviews yet.