Description
1. Introduction
The intravenous safety catheter with wings and injection port Nipro SafeTouch 20G x 50 mm (reference NIC-SF-2050PWP-ET) is the solution your nursing service needs to achieve fast, reliable and protected peripheral vascular access. It combines the comfort of a winged catheter, the Y injection port for administering medication without additional punctures, and a safety mechanism that protects the professional against accidental needlestick injuries, one of the most common occupational hazards in the hospital environment.
2. Technical Explanation
This peripheral safety catheter incorporates a passive activation system: upon removing the needle after venipuncture, the protective mechanism activates automatically and covers the tip, without requiring additional manoeuvres from the professional. The lateral wings allow a firm grip and precise control during insertion, as well as facilitating fixation of the catheter to the patient’s limb once cannulated. The integrated Y injection port allows administration of medication boluses or flushing of the system without disconnecting the main infusion line, reducing the risk of contamination and unnecessary manipulations. The cannula, made of thermosensitive polyurethane, adapts to the venous bed while maintaining its flexibility and strength, minimises the risk of kinking and is compatible with standard infusion, injection and transfusion solutions.
3. Technical Specifications
| Manufacturer reference | NIC-SF-2050PWP-ET |
| Brand / line | Nipro SafeTouch with wings and injection port |
| Gauge | 20G (pink) |
| Inner diameter | 0.8 mm |
| Usable length | 50 mm (2″) |
| Cannula material | Thermosensitive polyurethane, radiopaque |
| Safety system | Passive activation (SafeTouch) |
| Design | Fixation wings + Y injection port |
| Sterility | Sterile, single-use |
| Latex | Latex-free |
| Presentation | Box of 50 units |
| Indications | Intravenous infusion, injection and transfusion |
4. Equivalences and Cross-References
Within the same manufacturer family, this catheter shares the design (wings + Y injection port) with other available sizes. The references from the same line verified in official catalogue documentation are shown below:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Nipro | SafeTouch with wings and Y port | NIC-SF-2032PWP-ET | Exact reference equivalence (same family) | 20G x 32 mm: same line and design, shorter length |
| Nipro | SafeTouch with wings and Y port | NIC-SF-1832PWP-ET | Comparable by category (not interchangeable 1:1) | 18G x 32 mm: different gauge and length |
| Nipro | SafeTouch with wings and Y port | NIC-SF-1850PWP-ET | Comparable by category (not interchangeable 1:1) | 18G x 50 mm: different gauge, same length |
| Nipro | SafeTouch with wings and Y port | NIC-SF-1650PWP-ET | Comparable by category (not interchangeable 1:1) | 16G x 50 mm: larger gauge for high flow rates |
| Nipro | SafeTouch with wings (without Y port) | NIC-SF-2050PW-ET | Comparable by category (not interchangeable 1:1) | 20G x 50 mm without injection port: same gauge and length, but without Y port |
As for other manufacturers, the product is comparable at category level with peripheral safety catheters with injection port and wings from brands such as B. Braun (Introcan Safety line), BD (Nexiva and Insyte Autoguard lines) or Vygon (Leader-Cath). Before substituting in a tender or in an internal protocol, the professional must verify in the technical data sheet of each brand the following fields: equivalent gauge, cannula length, material (polyurethane versus other polymers), type of safety mechanism (active/passive), presence of injection port and presentation per box. There is no equivalence table validated by the manufacturer that cross-references these references with other brands; consult the technical department before using in a tender.
5. Selection tips and variants of interest
The 20G gauge with a length of 50 mm is a balanced choice for medium-duration access in adult patients with medium-calibre veins, suitable for most infusion fluids, medication administration and blood transfusions. For paediatric patients or those with fragile veins, it is recommended to reduce the gauge (22G x 25 mm, reference NIC-SF-2225P-ET from the SafeTouch line). For surgery, emergency or high-flow transfusions, opt for larger gauges such as 18G or 16G from the same family. If your protocol requires an injection port, always verify that the code includes the suffix “PWP” (Y port), since the SafeTouch line offers variants without a port that are not interchangeable 1:1. Always purchase presentations of 50 units to ensure correct stock rotation and availability in hospitalisation, emergency and operating theatre services.






Reviews