We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Intravenous safety catheter with wings and injection port Nipro SafeTouch 16G x 50 mm (1.7 mm) | Box of 50 units | Ref. NIC-SF-1650PWP-ET

65,40 €

Peripheral intravenous safety catheter 16G x 50 mm with wings and Y-injection port, from the Nipro SafeTouch line (ref. NIC-SF-1650PWP-ET). Its passive and irreversible safety mechanism covers the needle upon withdrawal with an audible locking click, reducing the risk of accidental needlestick injuries. Thermosensitive and radiopaque polyurethane cannula with a minimum flow rate of 162 ml/min, ideal for high-flow transfusions, surgery and emergencies. Latex-free, DEHP-free and PVC-free; sterile, single-use, in box of 50 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
NIC-SF-1650PWP-ET

Description

1. Introduction

The intravenous safety catheter with wings and injection port Nipro SafeTouch 16G x 50 mm (ref. NIC-SF-1650PWP-ET) is the solution your nursing service needs to achieve a high-flow, rapid, reliable and fully protected peripheral vascular access. It combines the comfort of secure wings, the versatility of a Y injection port and a passive safety mechanism that protects the professional against accidental needlestick injuries, one of the most frequent occupational hazards in the healthcare environment. Supplied in a box of 50 sterile units, it is the usual choice in operating theatres, emergency departments, hospitalisation and transfusion services when a large gauge and high flow rate are required.

2. Technical Explanation

This peripheral safety catheter incorporates a passive and irreversible activation system: when the needle is withdrawn after venipuncture, the stainless steel protector advances automatically and covers the tip, with the lock confirmed by an audible click, without requiring any additional manoeuvre from the professional and without changing the puncture technique. The flexible wings allow a firm grip and precise control during insertion, and also facilitate fixation of the catheter to the patient’s limb once it has been cannulated. The Y injection port with universal luer connector allows administration of medication boluses or flushing of the system without disconnecting the main line, reducing unnecessary manipulations and the risk of contamination. The thermosensitive and radiopaque polyurethane cannula softens at body temperature, adapting to the venous bed, minimising kinking and maintaining a guaranteed minimum flow rate of 162 ml/min. The stainless steel needle with triple bevel and silicone coating reduces penetration force and patient discomfort. It is manufactured latex-free, DEHP-free and PVC-free.

3. Technical Specifications

Manufacturer reference NIC-SF-1650PWP-ET
Brand / line Nipro SafeTouch, catheter with wings and injection port
Gauge 16G (grey)
Size (diameter x length) 1.7 x 50 mm (2″)
Minimum flow rate ≥ 162 ml/min
Cannula material Thermosensitive, radiopaque polyurethane (PUR)
Needle material Stainless steel SUS-304, triple bevel, silicone-coated
Safety system Passive and irreversible, with audible click lock (SafeTouch)
Design Colour-coded flexible wings + Y injection port with universal Luer connector
Sterility Sterile, single-use
Composition Latex-free, DEHP and PVC-free
Presentation Box of 50 units
Indications Intravenous infusion, injection and transfusion
Regulatory classification CE Class IIa medical device (Rule 7, MDD 93/42/EEC); compliant with ISO 10555-5, ISO 7864 and ISO 23908

Full range available in the same manufacturer’s line (catheter with wings and injection port), with references verified in the official technical data sheet:

Reference Gauge / Size Minimum flow rate
NIC-SF-1650PWP-ET 16G x 2″ (1.7 x 50 mm) ≥ 162 ml/min
NIC-SF-1832PWP-ET 18G x 1 1/4″ (1.3 x 32 mm) ≥ 81 ml/min
NIC-SF-1850PWP-ET 18G x 2″ (1.3 x 50 mm) ≥ 81 ml/min
NIC-SF-2032PWP-ET 20G x 1 1/4″ (1.1 x 32 mm) ≥ 49 ml/min
NIC-SF-2050PWP-ET 20G x 2″ (1.1 x 50 mm) ≥ 49 ml/min
NIC-SF-2225PWP-ET 22G x 1″ (0.8 x 25 mm) ≥ 29 ml/min
NIC-SF-2232PWP-ET 22G x 1 1/4″ (0.8 x 32 mm) ≥ 29 ml/min
NIC-SF-2419PWP-ET 24G x 3/4″ (0.7 x 19 mm) ≥ 17 ml/min
NIC-SF-2425PWP-ET 24G x 1″ (0.7 x 25 mm) ≥ 17 ml/min

4. Equivalences and Cross-References

Within the same manufacturer’s family (SafeTouch with wings and Y injection port), this catheter shares design, material and safety system with other sizes verified in the manufacturer’s official documentation:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Nipro SafeTouch with wings and injection port NIC-SF-1850PWP-ET Comparable by category (not interchangeable 1:1) 18G x 50 mm (1.3 x 50 mm): same length and design; smaller gauge and flow rate 81 ml/min. Reference verified in official data sheet
Nipro SafeTouch with wings and injection port NIC-SF-1832PWP-ET Comparable by category (not interchangeable 1:1) 18G x 32 mm: same design and safety system; smaller gauge and length
Nipro SafeTouch with wings (without injection port) NIC-SF-1650P-ET Comparable by category (not interchangeable 1:1) 16G x 50 mm: same gauge and length, but without Y injection port; not interchangeable if the protocol requires a Y port
B. Braun Introcan Safety® 3, 16G 1.7 x 50 mm, PUR, with wings 4251133-01 Comparable by category (not interchangeable 1:1) Same gauge, length and PUR material, with wings but without injection port in this variant (closed catheter with blood control); flow rate 185 ml/min. Reference verified in the manufacturer’s official catalogue

As for other manufacturers, the product is comparable at category level with peripheral safety catheters with injection port and wings from brands such as B. Braun (Introcan Safety line), BD (Nexiva and Insyte Autoguard lines) or Vygon (Leader-Cath). Before substituting in a tender or internal protocol, the professional must verify in each brand’s technical data sheet the following fields: equivalent gauge, cannula length, material (polyurethane versus other polymers), type of safety mechanism (active/passive), presence of injection port and presentation per box. There is no equivalence table validated by the manufacturer that cross-references these references with other brands; consult the technical department before use in a tender.

5. Selection tips and variants of interest

The 16G gauge with 50 mm length is the highest flow rate in the range (≥ 162 ml/min), making it the ideal choice for rapid blood and blood product transfusions, surgery, emergency care and administration of high-viscosity fluids in adult patients with good venous capital. For medium-duration access in patients with medium-sized veins, the 18G x 50 mm (ref. NIC-SF-1850PWP-ET) or 20G x 32/50 mm is recommended; for paediatric patients or those with fragile veins, reduce to 22G x 25 mm (ref. NIC-SF-2225PWP-ET) or 24G from the same line. If your protocol requires an injection port, always check that the code includes the PWP suffix (Y port), since the SafeTouch line offers variants without a port (P/PW suffix) that are not interchangeable 1:1. Always purchase 50-unit presentations to ensure correct stock rotation and availability in hospitalisation, emergency and operating theatre services.

Additional information

Gauge

16G (grey)

Size

1.7 x 50 mm (2")

Minimum flow rate

≥ 162 ml/min

Cannula material

Thermosensitive, radiopaque polyurethane (PUR)

Needle material

Stainless steel SUS-304, triple bevel, silicone-coated

Safety system

Passive and irreversible, with audible click lock (SafeTouch)

Design

Colour-coded flexible wings + Y injection port with universal Luer connector

Sterilisation

Sterile, single-use

Composition

Latex-free, DEHP and PVC-free

Presentation

Box of 50 units

Indications

Intravenous infusion, injection and transfusion

Regulatory classification

CE Class IIa medical device; compliant with ISO 10555-5, ISO 7864 and ISO 23908

Reference

NIC-SF-1650PWP-ET