Safe Touch winged safety intravenous catheter Nipro 18G x 50 mm (2″) – Box of 50 sterile units (Ref. NIC-SF-1850-PW-ET)

65,40 €

Safe Touch winged safety intravenous catheter Nipro 18G x 50 mm, in a box of 50 sterile units (ref. NIC-SF-1850-PW-ET). 18G (1.3 mm) gauge with a 50 mm cannula in thermosensitive and biocompatible polyurethane that softens at body temperature for greater patient comfort. Its passive safety system isolates the needle tip at the moment of withdrawal, reducing the risk of accidental needlestick injury to healthcare staff. Green colour coding, reference flow rate ≈ 90 ml/min and winged design for firm grip and stable fixation. Latex-free and PVC-free, with visible flashback for precise insertion. Ideal for transfusions, volume infusions and medication administration in hospitalisation, emergency and ICU.

International shipping. Import duties and taxes are payable by the recipient.

Reference
NIC-SF-1850-PW-ET

Description

1. Commercial Introduction

The Safe Touch winged intravenous safety catheter from Nipro in 18G gauge and 50 mm length is the ideal solution for establishing rapid, reliable and fully protected peripheral venous access in medium-to-large veins of adult patients. Its passive safety technology, biocompatible polyurethane cannula and winged design make it a common choice in hospitalisation, emergency, ICU, operating theatre, oncology and home care services, for infusions as well as transfusions of blood products and administration of large volumes. It is supplied in a box of 50 sterile units and is an essential ally in occupational risk prevention programmes for accidental needlestick injuries and blood exposure.

2. Technical explanation of the device

This peripheral safety catheter incorporates the Safe Touch technology, a passive protection mechanism that isolates and covers the needle tip at the moment of its withdrawal, activating automatically and irreversibly without changing the puncture technique or requiring additional manoeuvres from the professional. The transparent structure of the device allows easy confirmation of blood flashback during cannulation, ensuring precise insertion.

The cannula is made of thermosensitive and biocompatible polyurethane (PUR), a flexible and resistant material that softens with body temperature, reducing irritation of the venous wall and improving patient comfort. The lateral wings provide a firm grip during puncture and facilitate fixation of the device to the patient’s limb. All components are latex-free and PVC-free, and the product complies with the applicable requirements of standards ISO 10555-5, ISO 7864 and ISO 23908 as a CE Class IIa medical device.

3. Technical Specifications

Features verified from the GUDID/FDA regulatory registration (NIPRO SAFETOUCH IV CATHETER, reference NI-CSF1850PWET) and from the manufacturer’s official Safe Touch family documentation.

Specification Value
Brand / Line Nipro, Safe Touch family with wings (winged)
Reference (SKU Cahnos) NIC-SF-1850-PW-ET
Manufacturer catalogue code NI-CSF1850PWET (GUDID/FDA registration)
Gauge 18G (needle outer diameter 1.3 mm; green colour coding)
Size (cannula length) 50 mm (2″)
Reference flow rate ≈ 90 ml/min (Safe Touch 18G series; GUDID registration)
Cannula material Polyurethane (PUR) thermosensitive, biocompatible and radiopaque
Safety system Passive needle protection (anti-needlestick), automatic and irreversible activation
Design With wings for grip and fixation; transparent body for flashback verification
Injection port No (version without port; a variant with Y-type port exists in the same family)
Latex / PVC Latex-free and PVC-free
Sterility Sterile, single-use
Packaging Individual blister
Presentation Box of 50 units
Regulatory classification CE Class IIa medical device; compliant with ISO 10555-5, ISO 7864 and ISO 23908

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer that cross-references this reference with specific codes from other brands as direct 1:1 equivalents. After verifying official manufacturer catalogues and regulatory databases (GUDID/FDA), safety catheters have been identified that share clinical function, material and protection system, classified as comparable by category:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Nipro (same family) Safe Touch with wings 18G x 32 mm NIC-SF-1832PW-ET Comparable by category (not interchangeable 1:1) Same 18G gauge, same PUR material and same safety system; differs in cannula length (32 mm vs 50 mm). Reference verified in the manufacturer’s range.
Nipro (same family) Safe Touch with wings 16G x 50 mm NIC-SF-1650PW-ET Comparable by category (not interchangeable 1:1) Same 50 mm length and same safety system; differs in gauge (16G, higher flow rate for large-volume infusions). Reference verified in the manufacturer’s range.
Terumo Surshield™ Versatus WP (PUR, with needle protector) SR+DS1645PD Comparable by category (not interchangeable 1:1) PUR safety catheter with professional protection; differs in gauge (16G), length (45 mm), safety mechanism (guard-type needle cover vs Safe Touch passive clip) and absence of wings. Code verified in the manufacturer’s official datasheet.

At category level, the product is also comparable with 18G peripheral safety catheters from brands such as B. Braun (Introcan Safety® / Introcan Safety®-W family, winged), BD (Insyte™ Autoguard™ and Nexiva™ lines) and Vygon (Leader-Cath®), whose specific codes must be checked against each manufacturer’s official technical data sheet before any substitution. As this is a winged reference, without an injection port and with a 50 mm length, always verify gauge, length, cannula material (polyurethane versus FEP or other polymers), type of safety mechanism (active/passive), presence of wings and packaging per box. There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; consult the technical department before use in a tender.

5. Selection tips and variants of interest

The 18G (green) gauge provides a reference flow rate of ≈ 90 ml/min, making it ideal for blood product transfusions, large-volume infusions and fluid administration in adult patients with medium-to-large veins. Its 50 mm length offers a longer intracatheter path, useful in accesses with adipose panniculus or when a long cannula is required.

If you need the same family with a shorter length, the 18G x 32 mm (ref. NIC-SF-1832PW-ET) is available; if you require a higher infusion flow rate, consider the 16G x 50 mm (ref. NIC-SF-1650PW-ET); and if you prefer a finer gauge for smaller-diameter veins, the Safe Touch range with wings offers 20G (refs. NIC-SF-2032PW-ET and NIC-SF-2050PW-ET), 22G (refs. NIC-SF-2225PW-ET and NIC-SF-2232PW-ET) and 24G. To administer additional medication without reconnections, the same family has variants with a Y-type injection port. Always check the integrity of the sterile packaging before each use, use the device only once and dispose of it in an approved container for sharp healthcare waste.

Additional information

Brand

Nipro

Manufacturer reference

NI-CSF1850PWET

Gauge

18G (1.3 mm)

Colour code

Green

Cannula length

50 mm (2")

Flow rate

≈ 90 ml/min

Cannula material

Polyurethane (PUR) thermosensitive, biocompatible and radiopaque

Safety system

Passive needle protection (anti-needlestick)

Design

With wings; visible flashback

Injection port

Without port

Latex PVC

Latex-free and PVC-free

Sterility

Sterile, single-use

Packaging

Individual blister

Presentation

Box of 50 units

Regulatory classification

Medical device CE class IIa

Regulatory standard

ISO 10555-5, ISO 7864, ISO 23908

Indications

Peripheral intravenous access: infusions, transfusions and volume administration

Reviews

There are no reviews yet.

Be the first to review “Safe Touch winged safety intravenous catheter Nipro 18G x 50 mm (2″) – Box of 50 sterile units (Ref. NIC-SF-1850-PW-ET)”

Your email address will not be published. Required fields are marked *