Description
1. Commercial Introduction
The straight peripheral intravenous catheter Nipro 20G x 2″ (0.9 x 50 mm) pink, reference NIC-2050R-EJ, is the venous access solution your service needs to cannulate medium-calibre veins in adult patients with a free, simple and reliable puncture technique: hospitalisation, emergency, operating theatre, oncology, infusion units and home care. Its straight assembly, without wings and without a safety system, respects the classic cannulation technique and allows rapid, controlled insertion at a very competitive cost per unit. It is supplied in a box of 50 sterile single-use units, optimising stock rotation and availability in high-demand units.
2. Technical explanation of the device
It is a peripheral catheter of the over-the-needle type (over needle): the flexible cannula is mounted on a bevelled metal stylet that passes through skin and venous wall in a single step. Once inside the vein, the transparent body of the connector allows visual confirmation of blood flashback, an unmistakable sign of correct puncture; the cannula is then advanced, the stylet removed and the assembly secured with a standard dressing.
The 20G gauge corresponds to the pink colour code according to standard ISO 10555-5 and offers a medium-high flow rate, suitable for most drugs, maintenance fluids, contrast media and scheduled transfusions, with less trauma to the vascular endothelium than larger gauges. Its 50 mm (2″) length provides a longer intravascular course, useful for accesses with adipose panniculus or when a long cannula is required within the same gauge. Being a straight design, without wings or injection port, the device is very easy to secure and handle in direct cannulation protocols, minimising additional elements on the line.
3. Technical Specifications
| Brand / Line | Nipro, family of straight peripheral catheters |
| Reference (SKU) | NIC-2050R-EJ |
| Gauge | 20G (pink colour code, according to ISO 10555-5) |
| Size (diameter x length) | 0.9 x 50 mm (2″) |
| Design | Straight peripheral, without wings, without injection port, without safety system |
| Body | Transparent for blood flashback verification |
| Connection | Universal Luer, compatible with standard infusion lines |
| Sterility / use | Sterile, single-use |
| Presentation | Box of 50 units |
| Indications | Intravenous injection, infusion and transfusion |
Variants of the same family of Nipro straight peripheral catheters:
| Reference | Gauge | Size | Colour |
| NIC-1450R-EJ | 14G | 2″ | Orange |
| NIC-1650-EJ | 16G | 2″ (1.6 x 50 mm) | Grey |
| NIC-1832R-EJ | 18G | 1 1/4″ (1.4 x 21 mm) | Green |
| NIC-1850R-EJ | 18G | 2″ (1.2 x 50 mm) | Green |
| NIC-2032R-EJ | 20G | 1 1/4″ (0.9 x 32 mm) | Pink |
| NIC-2050R-EJ | 20G | 2″ (0.9 x 50 mm) — this product | Pink |
| NIC-2225R-EJ | 22G | 1″ (0.7 x 25 mm) | Blue |
| NIC-2232R-EJ | 22G | 1 1/4″ (0.7 x 32 mm) | Blue |
| NIC-2420-EJ | 24G | 3/4″ (0.55 x 20 mm) | Yellow |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references this product with specific codes from other brands as direct 1:1 equivalents. After verifying official manufacturer catalogues and internal documentation, no straight catheter without safety from another manufacturer has been found that simultaneously matches the 20G gauge, 50 mm length, straight design without wings and without injection port; therefore, the substitution cannot be classified as a 1:1 exchange.
As documented references for category approximation (comparable by category, not 1:1 interchangeable), the B. Braun 20G polyurethane catheters can be cited: Vasofix Safety G20 of 1.1 x 33 mm (ref. 4269110S-01) and Introcan Safety with wings G20 of 1.1 x 32 mm (ref. 4253566-01): both match in gauge and material, but incorporate a safety system and/or wings and injection port, and their length (32–33 mm) is shorter than the 50 mm of this reference, so they are not 1:1 interchangeable. At category level, the 20G peripheral catheter families from BD (Insyte™ and Venflon™ lines), Terumo (Surflo™ / Surshield™ Versatus) and Vygon (Leader-Cath®) are also comparable, whose specific codes for 20G x 50 mm must be checked in the official technical data sheet of each manufacturer before any substitution. Always verify gauge, cannula length, material (polyurethane versus other polymers), connection type, presence of wings or injection port, and safety system.
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before use in tendering.
5. Selection tips and variants of interest
The 20G gauge (pink) is one of the most used in daily clinical practice, indicated for medium-calibre veins and medium-high flow intravenous therapies in adult patients, as well as for transfusions and medication administration. Its 50 mm length offers a longer intravascular course, useful for accesses with adipose panniculus or when a long cannula is required.
- If you prefer the standard length of 1 1/4″ in the same gauge, the 20G x 32 mm variant is available (ref. NIC-2032R-EJ).
- If your protocol requires protection of the professional against accidental needlestick injuries (Directive 2010/32/EU), consider the SafeTouch safety range of the same gauge and length, ref. NIC-SF-2050P-ET (20G x 50 mm, polyurethane cannula with passive safety), which is not 1:1 interchangeable with this straight version without safety.
- For higher flow rates in adult patients, move up to the 18G (refs. NIC-1832R-EJ / NIC-1850R-EJ), 16G (ref. NIC-1650-EJ) or 14G (ref. NIC-1450R-EJ) gauges from the same family, always adjusting to the smallest gauge that allows the prescribed therapy.
- For finer veins (paediatrics, geriatrics), consider the 22G (refs. NIC-2225R-EJ / NIC-2232R-EJ) and 24G (ref. NIC-2420-EJ) gauges.
Always check the integrity of the sterile packaging and the expiry date before each use, use the device only once and dispose of it in an approved container for sharp healthcare waste.




Reviews