Description
1. Commercial Introduction
The combined blood and plasma bank Fiocchetti PLASMA-VISION 2T 400 TOUCH (ref. Cahnos FIO-DMD0402, factory code DMD0402) is the dual-temperature solution in a single vertical unit with two glass doors: it stores blood at positive temperature (+2/+6 °C) and frozen plasma at -10/-20 °C in two completely independent compartments, each with its own refrigeration unit. With a capacity of 358 litres, it is certified as a class IIa medical device in accordance with Directive 93/42/CEE and its amendment 2007/47/CEE, is registered in the Italian Ministry of Health’s Medical Devices Register and complies with the RoHS Directive 2011/65/CE.
The two glass doors allow visual supervision of the contents without opening the unit, minimising cold losses, while the customisable interior (shelves and drawers) optimises the storage of blood bags, fresh frozen plasma and blood products. It is the reference choice for blood banks, transfusion services and small and medium-volume laboratories that require rigorous thermal traceability. It is supplied on request and with a formalised quotation; please consult our technical-commercial team to configure the interior.
2. Technical explanation of the equipment
The PLASMA-VISION 2T series integrates two independent refrigeration circuits in a single vertical cabinet, allowing simultaneous storage of refrigerated blood (usually +4 °C) and frozen plasma (-20 °C) without the risk of cross-temperature contamination. The cooling is professional forced-air: cold air is distributed homogeneously throughout the chamber, with adaptive automatic defrosting and condensate evaporation, which eliminates manual maintenance and minimises thermal fluctuations.
The high-density injected polyurethane foam insulation (43 kg/m³), CFC-free and with ecological water injection, complemented by the Night & Day energy-saving function, ensures a contained consumption of 5 kWh/24h. The monobloc structure is made of steel with white antibacterial plasticised PVC (interior and exterior), with rounded corners and a chamber with a base; it includes 4 unidirectional wheels and two front feet for maximum stability, as well as Full LED lighting with intensity adjustment along the full height of the chamber.
The microprocessor controller ECT-F TOUCH with 7″ touchscreen simultaneously displays a real-time graph, the current temperature, the programmed setpoint and the alarm limits (both editable), the energy consumption and the battery status, with a resolution of 0.1 °C and an accuracy of ±0.3 °C. It includes as standard the independent recording module DMLP TOUCH with backup battery, which maintains the temperature and alarm log even during a power outage, the product temperature simulation probe and the electronic lock with a generic or user-specific password. The acoustic and visual alarms, which can be silenced, are automatically recorded with date, time, type, duration and maximum temperature reached. It is always possible to integrate the optional GSM and Wi-Fi modules and local or cloud monitoring systems.
3. Technical Specifications
3.1. Structure and refrigeration
| Parameter | Specification |
|---|---|
| Configuration | Combined refrigerator + freezer, 2 independent compartments with 2 refrigeration units and 2 glass doors |
| Temperature range | Compartment A (blood): +2/+6 °C | Compartment B (plasma): -10/-20 °C |
| Nominal capacity | 200+200 lt (7.06+7.06 cu ft) |
| Net capacity | 170+160 lt (6.01 + 5.66 cu ft) |
| Internal dimensions | 50 x 48.5 x 68.5 / 50 x 48.5 x 73 cm |
| External dimensions (HxDxW) | 60 x 66 x 202 cm |
| Insulation type | High-density injected polyurethane foam in the walls (43 kg/m³), CFC-free and with ecological water injection |
| Insulation thickness | 70 mm rear / 50 mm on the sides |
| Structure | Steel with white antibacterial plasticised PVC (interior and exterior) or with internal structure in 18/10 AISI 304 steel; rounded corners and chamber with a base |
| Mobility | 4 unidirectional castors included + 2 front feet for maximum stability |
| Internal lighting | Full LED across the full height of the chamber, with intensity adjustment |
| Cooling type | Professional ventilated |
| Defrosting type | Adaptive automatic with condensate evaporation |
| Energy saving | Night & Day function |
3.2. Electronic controller ECT-F TOUCH and safety
| Characteristic | Description |
|---|---|
| Display | 7″ touchscreen with real-time graph; resolution 0.1 °C and accuracy ±0.3 °C |
| Registration | Temperatures and alarms with date, time, type, duration and maximum temperature; history on SD card |
| Ports | SD card (data history), USB (download and system update) and SIM card (for optional GSM module) |
| Connectivity | Integrated web server for LAN (RJ45) and MODBUS TCP/IP; dry contacts for remote alarm |
| DMLP TOUCH module | Independent recording with backup battery (works during power outage); product temperature simulation probe |
| Safety | Anti-freezing and anti-overheating devices; electronic lock with generic or user-specific password; silenceable acoustic and visual alarms |
| Optional accessories | GSM and Wi-Fi modules; local and cloud monitoring systems |
3.3. Technical data of the refrigerator
| Parameter | Value |
|---|---|
| Refrigerant gas type | R290 |
| Consumption | 5 kWh/24h |
| Absorbed power | kW 0.17+0.32 / Amp 1+2.3 |
| Starting absorption | Amp 3+5 |
| Noise level | <50 dBA |
| Heat output EN 12900 | W 208 |
| Number of shelves included | 4 (2+2) |
| Max. no. of shelves | 3+3 |
| Shelf dimensions | cm 46×45 |
| Max. no. of drawers | 5+3 |
| Internal dimension of drawers with dividers (LxDxH) x number of spaces | cm 11.8x40x7.5 (3) |
| Internal dimension of the drawers without dividers (LxDxH) | cm 39x40x7.5 |
| Max. number of stainless steel wire drawers | 5+3 |
| Internal dimension of stainless steel wire drawers (LxDxH) | cm 43.5×40.5×6.2 |
| Classification | Medical device class IIa (Directive 93/42/CEE and amendment 2007/47/CEE); RoHS 2011/65/CE |
3.4. Available references
| Model | Fiocchetti code | Controller | Temperature range | Capacity | External dimensions (HxDxW) |
|---|---|---|---|---|---|
| PLASMA-VISION 2T 400 TOUCH | DMD0402 | ECT-F TOUCH | +2/+6°C | -10/-20°C | 358 L (12.64 cu ft) | 60 x 66 x 202 |
Variants of the same series (glass doors):
| Model | Fiocchetti code | Controller | Temperature range | Capacity | External dimensions (HxDxW) |
|---|---|---|---|---|---|
| PLASMA-VISION 2T 500 TOUCH | DMD0502 | ECT-F TOUCH | +2/+6°C | -10/-20°C | 486 lt (17.16 cu ft) | 72 x 76 x 208 |
| PLASMA-VISION 2T 700 TOUCH | DMD0702 | ECT-F TOUCH | +2/+6°C | -10/-20°C | 593 L (20.94 cu ft) | 72 x 85.5 x 203 |
4. Equivalences and Cross-References
The factory code for this unit is DMD0402 (model PLASMA-VISION 2T 400 TOUCH), verified in the official technical data sheet of the manufacturer Fiocchetti Scientific S.r.l. and on its corporate website; the corresponding Cahnos SKU is FIO-DMD0402. The variants of the same series and from the same manufacturer with glass doors are DMD0502 (2T 500, 486 litres) and DMD0702 (2T 700, 593 litres), identical in controller and certification and differing only in capacity and dimensions. As variants from the same manufacturer with a solid door, the PLASMA-LABOR 2T series offers DML0402, DML0502 and DML0702, and the PLASMA-SUPERARTIC 2T series offers the DMT0702 (-20/-40 °C).
There is no manufacturer-validated equivalence table linking this model to specific codes from other manufacturers of combined blood bank refrigerator-freezer cabinets with glass doors; consult the technical department before use in tenders. The homologous brands and families in the sector for this category (dual-temperature blood + plasma cabinets, positive range +2/+6 °C and frozen -20/-25 °C, with continuous recording and alarms, for blood bank and transfusion use) include Angelantoni Life Science, Kirsch, Liebherr (Medline range), Gram and Labcold. They are comparable at category level, not interchangeable 1:1: each manufacturer has different chamber geometry, controller, internal fittings, door type, consumption, refrigerant gas and certifications. Before any replacement, compare field by field the thermal range of both compartments, net capacity, dimensions, chamber material, controller type and regulatory classification (class IIa) of the actual product, validating it with the Cahnos technical department.
5. Selection tips and variants of interest
Installation space: allow access for a unit measuring 60 x 66 x 202 cm (W x D x H) and ensure adequate ventilation at the rear (70 mm insulation). Check doorways, corridors and delivery platform before placing the order; the unit includes 4 unidirectional castors for easy manoeuvring.
Traceability and compliance: if your specification requires independent continuous recording and alerts in the event of power cuts, this model includes it as standard with the DMLP TOUCH module with backup battery, product temperature simulation probe, dry contacts and RJ45 port. For hospital network integration, request the GSM/Wi-Fi modules and cloud monitoring.
Internal configuration: the unit accepts up to 3+3 shelves (includes 4 as standard, 46×45 cm) and up to 5+3 drawers with or without dividers, as well as stainless steel wire drawers, allowing blood bags (red cell concentrates, platelets) and fresh frozen plasma to be organised according to the workflow of your service. Racks and accessories are quoted separately.
Variants of the same family: if your patient volume is higher, the PLASMA-VISION 2T series offers models 500 (DMD0502, 486 litres) and 700 (DMD0702, 593 litres), both with the same controller and certification. If your centre prefers a solid door, consider the PLASMA-LABOR 2T series (DML0402 and DML0502). If you only need to store frozen plasma, consult the PLASMA-VISION series (DMV0402, DMV0702) or PLASMA-FREEZER TOUCH. Sales are made under a formal quotation; contact our technical-commercial team to size the correct solution and receive the regulatory documentation (technical data sheet, CE certificate) for tenders and competitions.