We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Combined blood and plasma bank Fiocchetti PLASMA-LABOR 2T 500 TOUCH (Ref. FIO-DML0502) | +2/+6 °C and -10/-25 °C, 486 litres, class IIa medical device

Price on request

Heavy / bulky product. Shipping is neither free nor included in the price: it depends on the destination, Cahnos subsidises part of it and we will confirm the cost separately after your order. If you need it before buying, please contact us.

Refrigerator-freezer combined and certified as a class IIa medical device for storing blood (+2/+6 °C) and plasma (-10/-25 °C) in two independent compartments within a single 486-litre vertical unit. 7″ touch controller with real-time graph, independent DMLP TOUCH recording module with backup battery (works during power outage), temperature simulation catheter, electronic lock, RJ45 port with web server and MODBUS TCP/IP protocol. Professional ventilated refrigeration with eco-friendly R290 gas, automatic defrost, Full LED lighting and 75 mm polyurethane insulation. Ideal for blood banks, transfusion services and laboratories that need to store blood products with full thermal traceability.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIO-DML0502

Description

1. Commercial Introduction

The Fiocchetti PLASMA-LABOR 2T 500 TOUCH combined blood and plasma bank (ref. Cahnos FIO-DML0502, factory code DML0502) is the dual-temperature solution in a single vertical unit: it stores blood at positive temperature (+2/+6 °C) and frozen plasma at -10/-25 °C (usual setpoint -20 °C) in two completely independent compartments, each with its own refrigeration unit and solid closing door.

With a total capacity of 486 litres (250+250 nominal), it is certified as a class IIa medical device in accordance with Directive 93/42/EEC and its amendment 2007/47/EC, registered in the Italian Ministry of Health’s Medical Devices Register, and complies with standard DIN 13277 and Directive RoHS 2011/65/EU. It is the reference choice for blood banks, transfusion services and medium-to-high volume laboratories that demand rigorous thermal traceability and regulatory compliance in tenders and bids. It is supplied on order and formal quotation; consult our technical-commercial team to configure the interior.

2. Technical explanation of the equipment

The PLASMA-LABOR 2T series integrates two independent refrigeration circuits in a single vertical cabinet, allowing refrigerated blood and frozen plasma to be maintained simultaneously without risk of cross-contamination of temperatures. The cooling is professional forced-air: cold air is distributed homogeneously throughout the chamber, with adaptive automatic defrosting and condensate evaporation, eliminating manual maintenance and reducing thermal fluctuations. The high-density injected polyurethane foam insulation (43 kg/m³, 75 mm at the rear and 60 mm at the sides), CFC-free and with ecological water injection, ensures a contained consumption of 4.5 kWh/24h.

The ECT-F TOUCH microprocessor controller with 7″ touchscreen simultaneously displays a real-time graph, current temperature, programmed setpoint and alarm limits (both editable), energy consumption and battery status, with a resolution of 0.1 °C and accuracy of ±0.3 °C. It includes as standard the independent recording module DMLP TOUCH with backup battery that maintains the temperature and alarm record even during a power outage, the product temperature simulation probe (instead of ambient), electronic lock with generic or individual password per user, dry contacts for remote alarm and RJ45 port with integrated web server and MODBUS TCP/IP protocol. The acoustic and visual alarms, which can be silenced, are automatically recorded with date, time, type, duration and maximum temperature reached. It is always possible to integrate the optional GSM and Wi-Fi modules and local or cloud monitoring systems.

3. Technical Specifications

Structure and refrigeration

Parameter Specification
Configuration Combined refrigerator + freezer, 2 independent compartments with 2 refrigeration units and 2 solid doors
Temperature range Compartment A (blood): +2/+6 °C | Compartment B (plasma): -10/-25 °C
Nominal capacity 250+250 litres (8.82+8.82 cu ft)
Net capacity 249+230 litres (8.80 + 8.13 cu ft)
Internal dimensions 60 x 58.8 x 70 / 60 x 58.8 x 74 cm
External dimensions (HxDxW) 72 x 74.5 x 208 cm
Insulation type High-density injected polyurethane foam (43 kg/m³), CFC-free, with ecological water injection
Insulation thickness 75 mm rear / 60 mm sides
Structure Steel with white antibacterial plastified PVC (interior and exterior), rounded corners and chamber with base
Mobility 4 unidirectional wheels + 2 front stability feet
Internal lighting Full LED across the full height of the chamber, with intensity adjustment
Cooling type Professional ventilated
Defrosting type Adaptive automatic with condensate evaporation
Energy saving Night & Day function

ECT-F TOUCH electronic controller

Characteristic Description
Display 7″ touchscreen with real-time graph; resolution 0.1 °C and accuracy ±0.3 °C
Registration Temperatures and alarms with date, time, type, duration and maximum temperature; history on SD card
Ports SD card, USB (download and update) and SIM card (for optional GSM module)
Connectivity Integrated web server for LAN (RJ45) and MODBUS TCP/IP; dry contacts for remote alarm
DMLP TOUCH module Independent recording with backup battery (operates during power outage); product temperature simulation probe
Safety Anti-freezing and anti-overheating devices; electronic lock with generic or per-user password; silenceable acoustic and visual alarms
Optional accessories GSM and Wi-Fi modules; local and cloud monitoring systems

Technical data of the refrigerator

Parameter Value
Refrigerant gas type R290
Consumption 4.5 kWh/24h
Absorbed power kW 0.17+0.32 / Amp 1+2.3
Starting absorption Amp 3+5
Noise level <50 dBA
Heat emitted (EN 12900) 187 W
Shelves included / max. 4 (2+2) / max. 3+3 — dimensions cm 56×55
Drawers max. 3+3 — with dividers (LxDxH): cm 15x50x7.5 (3 spaces); without dividers: cm 49x50x7.5
Classification Class IIa medical device (Directive 93/42/EEC and amendment 2007/47/EC); standard DIN 13277; RoHS 2011/65/EC

Available references in the series

Model Fiocchetti code Controller Temperature range Capacity External dimensions (HxDxW)
PLASMA-LABOR 2T 280 TOUCH DML0282 ECT-F TOUCH +2/+6°C | -10/-20°C 306 lt (10.81 cu ft) 52 x 66.5 x 177.5 cm
PLASMA-LABOR 2T 400 TOUCH DML0402 ECT-F TOUCH +2/+6°C | -10/-25°C 358 L (12.64 cu ft) 60 x 64.5 x 202 cm
PLASMA-LABOR 2T 500 TOUCH DML0502 ECT-F TOUCH +2/+6°C | -10/-25°C 486 lt (17.16 cu ft) 72 x 74.5 x 208 cm

4. Equivalences and Cross-References

The manufacturer’s factory code for this equipment is DML0502 (model PLASMA-LABOR 2T 500 TOUCH), verified in Fiocchetti’s official technical documentation; the corresponding Cahnos SKU is FIO-DML0502. The variants of the same series and same manufacturer are DML0282 (2T 280) and DML0402 (2T 400), identical in controller and certification and differing only in capacity and dimensions.

There is no equivalence table validated by the manufacturer relating this model to specific codes from other manufacturers of combined refrigerator-freezer units for blood banks; consult the technical department before using in a tender. The homologous brands and families in the sector for this category (dual-temperature blood + plasma cabinets, positive range +2/+6 °C and frozen -25/-30 °C, with continuous recording and alarms, for blood bank and transfusion use) include Angelantoni Life Science (blood and plasma banks with dual circuit), Kirsch (medical refrigeration and freezing lines for blood products), Liebherr (Medline range for laboratory and blood bank), Gram and Labcold. They are comparable at category level, not interchangeable 1:1: each manufacturer has different chamber geometry, controller, internal equipment (shelves, drawers, baskets), consumption, refrigerant gas and certifications. Before any substitution, compare field by field: thermal range of both compartments, net capacity, external and internal dimensions, chamber material, type of controller and alarm recording, and MDR regulatory classification (class IIa) of the actual product, validating it with the Cahnos technical department.

5. Selection tips and variants of interest

Installation space: provide access for equipment measuring 72 x 74.5 x 208 cm (WxDxH) and ensure adequate ventilation at the rear (75 mm insulation). Check doorways, corridors and delivery platform before placing the order.

Traceability and regulations: if your tender requires independent continuous recording and alerts in the event of power cuts, this model includes it as standard with the DMLP TOUCH module with backup battery, product temperature simulation probe, dry contacts and RJ45. For hospital network integration, request the GSM/Wi-Fi modules and cloud monitoring.

Internal configuration: the equipment accepts up to 3+3 shelves (56×55 cm) and 3+3 drawers with or without dividers, allowing blood bags (red blood cell concentrates, platelets) and fresh frozen plasma to be organised according to the flow of your service. The racks and accessories are quoted separately.

Variants of the same family: if your care volume is lower, the PLASMA-LABOR 2T series offers the 400 model (DML0402, 358 litres) and the 280 model (DML0282, 306 litres) with identical controller and certification. If you only need to store frozen plasma, see the PLASMA-FREEZER TOUCH series (DMF0142, DMF0252, DMF0402, DMF0702 and DMF1502). Sales are made under a formal quotation; contact our technical-commercial team to size the correct solution and receive the regulatory documentation (technical data sheet, CE/MDR certificate) for tenders and bids.

Additional information

Product line

PLASMA-LABOR 2T

Controller

ECT-F TOUCH with 7" touch screen

Capacity

486 lt (17.16 cu ft)

Dimensions

72 x 74.5 x 208 cm

Manufacturer reference

DML0502

Product type

Combined refrigerator-freezer for blood and plasma bank (medical device class IIa)

Configuration

2 independent compartments, 2 refrigeration units and 2 solid doors

Temperature range

+2/+6 °C (blood), -10/-25 °C (plasma)

Nominal capacity

250+250 litres

Net capacity

249+230 litres (486 litres total)

External dimensions

72 x 74.5 x 208 cm (WxDxH)

Internal dimensions

60 x 58.8 x 70 / 60 x 58.8 x 74 cm

Refrigerant gas

R290

Energy consumption

4.5 kWh/24h

Data recording

Independent DMLP TOUCH module with backup battery; product temperature simulation probe

Connectivity

RJ45 with web server and MODBUS TCP/IP; dry contacts for remote alarm; SD, USB and SIM ports

Insulation

High-density injected polyurethane foam (43 kg/m3), CFC-free; 75 mm rear / 60 mm sides

Refrigeration

Professional ventilated with adaptive automatic defrost

Lighting

Full LED with intensity adjustment

Safety

Electronic lock with password; silenceable acoustic and visual alarms; anti-freezing and anti-overheating devices

Regulatory standard

Directive 93/42/EEC and amendment 2007/47/EEC (class IIa); DIN 13277; RoHS 2011/65/EC

Shelves

4 included (2+2); max. 3+3 (cm 56×55)

Drawers

Max. 3+3; with dividers cm 15x50x7.5 (3 spaces); without dividers cm 49x50x7.5

Documentation

Reviews

There are no reviews yet.

Be the first to review “Combined blood and plasma bank Fiocchetti PLASMA-LABOR 2T 500 TOUCH (Ref. FIO-DML0502) | +2/+6 °C and -10/-25 °C, 486 litres, class IIa medical device”

Your email address will not be published. Required fields are marked *

You may also like…