Description
1. Introduction
The 15 mm pass-through port (ref. Cahnos FIO-ACC-2315, Fiocchetti request code PID 2315) is an original accessory from the Italian manufacturer Fiocchetti, designed to be installed in the door of medical and laboratory refrigeration equipment from the EMOTECA, FREEZER, LABOR, MEDIKA, SUPERARTIC, VISION, CROMATOGRAPHY and PLASMA-FREEZER series. It allows temperature probes, sensors or small-diameter cables to pass into the chamber while keeping the door closed and the chamber sealed.
It is the practical solution for continuous temperature monitoring, verification with reference probes, thermal mapping studies and the integration of external recording systems, without compromising thermal stability or traceability of the stored product. It is sold on quotation: Fiocchetti configures each unit and each accessory according to customer specifications.
2. Technical explanation of the accessory
The 15 mm pass-through port is a feed-through element (cable entry hole) mounted on the door panel of the refrigeration unit. Its function is to allow the entry of probes and cables from the outside into the refrigerated chamber with the door fully closed, avoiding the thermal leakage that would result from leaving the door ajar or damaging the door gasket when passing a cable through the frame.
This type of access is particularly useful in blood banks and transfusion services, where the actual product temperature must be monitored continuously and in an auditable manner (simulated probe or reference probe), as well as in plasma freezers and ultra-low temperature freezers where the slightest door opening causes cold loss and risk of condensation. The nominal passage diameter is 15 mm, sufficient for PT100 probes, thermocouples and small-gauge sensor wiring.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Accessory type | Pass-through port / cable feed-through for door |
| Nominal passage diameter | 15 mm |
| Manufacturer | Fiocchetti Scientific S.r.l. (Luzzara, Italy) — Italian manufacture |
| Manufacturer request code | PID 2315 (official datasheet reference: Port mm 15) |
| Reference Cahnos | FIO-ACC-2315 |
| Intended use | Passage of temperature probes, sensors and cables into the chamber with the door closed |
| Installation | On the equipment door; installation recommended by technical service |
| Commercialisation | On request / subject to quotation |
| Presentation | Unit |
Compatibility (according to official Fiocchetti datasheet)
| Family | Compatible models |
|---|---|
| EMOTECA (blood bank) | EMOTECA 100, EMOTECA 140, EMOTECA 1500, EMOTECA 170, EMOTECA 200, EMOTECA 250, EMOTECA 2T 280, EMOTECA 2T 400, EMOTECA 2T 500, EMOTECA 400, EMOTECA 500, EMOTECA 700, EMOTECA TWIN 1500, EMOTECA TWIN 250, EMOTECA TWIN 400, EMOTECA TWIN 700 |
| FREEZER (plasma freezer) | FREEZER 140, FREEZER 1500, FREEZER 250, FREEZER 400, FREEZER 700 |
| LABOR | LABOR 100, LABOR 140, LABOR 1500, LABOR 170, LABOR 200, LABOR 250, LABOR 2T 280, LABOR 2T 400, LABOR 2T 500, LABOR 2T 700, LABOR 400, LABOR 500, LABOR 700 |
| MEDIKA | MEDIKA 100, MEDIKA 140, MEDIKA 1500, MEDIKA 170, MEDIKA 200, MEDIKA 250, MEDIKA 2T 1000, MEDIKA 2T 1500, MEDIKA 2T 280, MEDIKA 2T 400, MEDIKA 2T 500, MEDIKA 2T 600, MEDIKA 2T 800, MEDIKA 300, MEDIKA 400, MEDIKA 500, MEDIKA 700, MEDIKA 700 PT |
| SUPERARTIC | SUPERARTIC 400 |
| VISION | VISION 2T 700, VISION 400, VISION 700 |
| CROMATOGRAPHY | CROMATOGRAPHY 1500, CROMATOGRAPHY 700 |
| PLASMA-FREEZER | PLASMA-FREEZER 140, PLASMA-FREEZER 1500 |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer for this accessory: Fiocchetti does not publish official cross-references of its pass-through ports against other brands, so no exact reference equivalence can be declared. It is recommended to consult the technical department at Cahnos before using it in a tender.
In terms of functional comparison by category (not interchangeable 1:1), door-mounted cable feed-through ports or probe pass-through accesses are available as an option from most medical refrigeration manufacturers for blood bank, plasma and ultra-low temperature freezing (e.g. B Medical Systems, Helmer Scientific, Kirsch or Thermo Fisher Scientific), usually in diameters from 10 to 35 mm. Before considering any replacement with accessories from other brands, the following must be verified: passage diameter, geometry and thickness of the door panel, fixing system, material and tightness, as well as the compatibility of the probe to be inserted. The original manufacturer of the Cahnos brand is not cited either as manufacturer or as competitor.
Within the Fiocchetti range itself, the larger-diameter variant port mm 35 with plug covers wider pass-through needs; check the datasheet for compatibility with your equipment model before choosing.
5. Selection tips and variants of interest
Before ordering this accessory, confirm the exact model of your equipment (series and capacity) to verify the compatibility of the port on the corresponding door. If the probe or cable to be passed through exceeds 15 mm in diameter, consider the larger-diameter variant with plug (port mm 35).
For installations intended for continuous monitoring with auditable recording, combine this port with reference or product-simulation probes and external data loggers; installation must be carried out by qualified technical personnel to preserve the tightness and thermal conditions of the chamber. This accessory is supplied on order and quotation; contact our sales team to confirm lead times, compatibility and terms.