Oocyte Puncture Needle PM-LIFE® OVO-PUNC 17G – ext. Ø 1.5 mm / int. Ø 1.2 mm x 30 cm for IVF | Ref. PS1341530

140,00 €

PM-LIFE® OVO-PUNC (ref. PS1341530) is the ultrasound-guided oocyte puncture needle in 17G gauge, with a working length of 30 cm and an external diameter of 1.5 mm that ensures optimal flow in follicular suction. Made of medical stainless steel, it is sterile by gamma radiation, single-use and latex-free, with class IIa and CE marking. Its thin-wall design offers excellent ultrasound visibility and precise, reproducible oocyte recovery during in vitro fertilisation (IVF) cycles. Presentation in a box of 10 units in individual sterile packaging, with a shelf life of 5 years. Ideal for assisted reproduction laboratories and fertility clinics that require a versatile loose needle, compatible with external suction systems.

International shipping. Import duties and taxes are payable by the recipient.

Reference
PS1341530

Description

1. Introduction

The PM-LIFE® OVO-PUNC needle (ref. PS1341530) is the ideal solution for ultrasound-guided puncture of ovarian follicles in in vitro fertilisation (IVF) cycles. Designed by and for assisted reproduction specialists, it enables oocyte retrieval with maximum safety, precision and care for the biological material. It is supplied in a box of 10 units in individual sterile packaging, ready for use in the operating theatre or fertility clinic.

2. Technical explanation of the equipment and procedure

Ultrasound-guided follicular puncture is the standard technique for obtaining oocytes before in vitro fertilisation. The PM-LIFE® OVO-PUNC needle combines a 17G gauge and a working length of 30 cm that allow ovarian follicles to be reached through the vaginal transducer guide with excellent ultrasound visibility throughout the entire path. Its internal diameter of 1.2 mm ensures an efficient suction flow of the follicular fluid, minimising trauma to the cumulus-oocyte complex. As an individual needle without a valve, the vacuum is regulated from the external pump or suction system, which simplifies the circuit and handling during the procedure, guaranteeing safe and reproducible oocyte recovery in each cycle.

3. Technical Specifications

Parameter Specification
Reference PS1341530
Brand / Range PM-LIFE® OVO-PUNC
Needle gauge 17G
Outer diameter 1.5 mm
Inner diameter 1.2 mm
Usable length 30 cm
Use Single-use
Class IIa
Sterile Yes
Sterilisation method Gamma radiation
Contains latex No
Shelf life 5 years
Certification CE
Launch date 2002
Presentation Box of 10 units in individual sterile packaging
Storage In its original box, in a cool, dry place

4. Equivalences and Cross-References

The PM-LIFE® OVO-PUNC needle (PS1341530) shares gauge and needle dimensions (17G, ext. Ø 1.5 mm, int. Ø 1.2 mm) with the kits in the same range. The OVO-KIT without valve PS3251533 integrates a needle with the same dimensional characteristics with a working length of 31.5 cm, together with a fixation base, Luer-Lock tubes and a Falcon-type cap, presented in a box of 5 kits. The OVO-KIT with three-way valve PS4341533 adds a stopcock with Luer-Lock base for direct vacuum control, in a box of 4 kits. In routine clinical practice, the loose needle and the kits are interchangeable depending on each centre’s protocol: the PS1341530 is the recommended option for diagnostic aspiration, training or maximum flexibility of use, maintaining identical flow and ultrasound visibility performance.

5. Selection tips and variants of interest

Select the PM-LIFE® OVO-PUNC needle (PS1341530) when your team has a suction pump with external vacuum regulation and prefers a loose, versatile needle with excellent value for money per unit. If your protocol requires a complete ready-to-use circuit, opt for the valve-free kit PS3251533; if you need an airtight seal and direct control of the vacuum opening from the needle, choose the kit with valve PS4341533. Always verify the working length (30 cm) and the 17G gauge to ensure compatibility with your usual vaginal transducer and ultrasound catheters. All products are single-use: do not reuse under any circumstances. Consult our technical-commercial team at Cahnos for validation of stock under order and quotation conditions.

Additional information

Reference

PS1341530

Brand / Range

PM-LIFE OVO-PUNC

Gauge

17G

Inner diameter

1.2 mm

Usable length

30 cm

Material

Medical stainless steel

Bevel type

Standard bevel for follicular suction

Class

IIa

Sterilisation

Gamma radiation

Shelf life

5 years

Certifications

CE

Presentation

Box of 10 units in individual sterile packaging

Storage

In its original box, in a cool, dry place

Compatibility

Suction systems with external vacuum regulation