Description
1. Commercial Introduction
The Rigid Hysterographic Catheter PM-CARE® 1V-STD small model (Ref. PS1870733) is Prince Medical’s solution for contrast studies of the uterine cavity in patients with a cervix of usual diameter. Its polyurethane foam sealing cone of Ø 15 mm rests against the cervix and guarantees a watertight seal throughout the examination, preventing reflux of the contrast medium. A sterile, single-use, latex-free device designed for gynaecological diagnostic radiology departments, gynaecology clinics and assisted reproduction units.
2. Technical explanation of the equipment and procedure
This catheter is indicated for performing hysterographies (X-rays with contrast medium) and hysterosonographies (ultrasound imaging with physiological saline or saline solution), as well as for evaluating the uterine cavity in fertility studies. It consists of a transparent Pebax catheter, a 1-way stopcock fixed to the body, a rigid polyester handle and a polyurethane foam sealing cone. The foam is positioned against the cervix and acts as an obturator: it prevents contrast reflux and maintains watertightness throughout the examination. Its rigid structure provides stability and atraumatic insertion, while the no-touch insertion technique preserves the sterility of the device. The diameter of 7.5 Fr (2.45 mm) is ideal for firm access to the cervical canal.
3. Technical Specifications
Data verified according to the technical data sheet from the manufacturer Prince Medical for reference PS1870733:
| Parameter | Value |
|---|---|
| Type | Rigid single-lumen hysterographic catheter with foam |
| Model | Small (Ø 15 mm foam) |
| Brand / Line | PM-CARE® 1V-STD (Prince Medical) |
| Reference | PS1870733 |
| Number of ways | 1 lumen (1-way stopcock) |
| Catheter diameter | 2.45 mm (7.5 Fr) |
| Foam diameter | 15 mm |
| Catheter length | 330 mm |
| Sealing mechanism | Polyurethane foam sealing cone |
| Materials | Pebax catheter, rigid polyester handle, polyurethane foam |
| Use | Single-use |
| Device class | Is |
| Sterile | Yes |
| Sterilisation method | Ethylene oxide |
| Contains latex | No |
| Shelf life | 5 years |
| Certification | CE |
| Launch date | 2004 |
| Presentation | Box of 5 units in individual sterile packaging |
| Storage | In its original box, in a cool, dry place |
References for the PM-CARE® 1V-STD family (catheters with foam):
| Reference | Model | Foam diameter | Length | Packaging |
|---|---|---|---|---|
| PS1870733 | Small | 15 mm | 330 mm | Box of 5 units |
| PS2010733 | Large | 25 mm | 330 mm | Box of 5 units |
| PS2020733 | Sliding | 15 mm | 340 mm | Box of 5 units |
Comparison of the three 1V-STD variants:
| Characteristic | Small (PS1870733) | Large (PS2010733) | Sliding (PS2020733) |
|---|---|---|---|
| Catheter diameter | 2.45 mm (7.5 Fr) | 2.45 mm (7.5 Fr) | 2.45 mm/1.5 mm (7.5/4.5 Fr) |
| Foam diameter | 15 mm | 25 mm | 15 mm |
| Length | 330 mm | 330 mm | 340 mm |
| Sliding catheter | No | No | Yes |
4. Equivalences and Cross-References
This catheter belongs to the PM-CARE® family from Prince Medical (French manufacturing), available in full in the Cahnos catalogue. Within the same foam-sealing range are the large model (PS2010733, 25 mm foam) and the sliding model (PS2020733), which share design, materials and cervical obturation system. As alternatives for cervical sealing in hysterography and hysterosonography, the catalogue offers the malleable 3-way balloon catheter PM-CARE® 3V-BALLOON (Ref. PS3310733), indicated when silicone balloon fixation is preferred, and the rigid 2-way vacuum-cup catheters PM-CARE® 2V-CUP (Refs. PS4292340, PS4292840, PS4293540 and the PS3460845 set), comparable to suction cup systems used in gynaecological radiology. To extend the injection line outside the radiological field, the PM-CARE® EXTEND extensions of 20 cm (PS0700002) or 140 cm (PS0700014) can be used. Functionally, the concept of a catheter with a cervical sealing element is equivalent to that of other balloon hysterosalpingography devices present on the European market; our technical-sales team can verify exact gauge and length equivalences according to your protocol.
5. Selection tips and variants of interest
Select reference PS1870733 (small model) for a standard examination with a cervix of usual diameter: its 15 mm foam adapts to the cervix with a comfortable and effective seal. For larger-diameter cervices, common in multiparous patients, choose the large model (PS2010733) with 25 mm foam. If you need to reach deeper areas of the cavity or adjust the tip during injection, consider the sliding model (PS2020733). If your centre prefers alternative sealing systems, consider the PS3310733 balloon catheter or the vacuum cups of the 2V-CUP range. It is recommended to use a no-touch insertion technique, not to use the device if the internal packaging is damaged and to store the box horizontally in a cool, dry place. For large-volume orders or specific needs, consult our technical-sales team at Cahnos.