Description
1. Introduction: precision in cervical cancer screening
The exo/endocervical cytological brush (ref. 0658046) is the reference device for cervical cell sampling in gynaecology clinics, health centres and screening units. Designed for liquid-based cytology (LBC) —the current method for cervical cancer screening in Spain, which replaces the conventional Papanicolaou smear—, it allows a representative sample of the cervical transformation zone to be obtained in a single manoeuvre, essential for reliable diagnosis according to the Bethesda System. Single-use, latex-free and with a detachable head, it is designed to streamline the daily work of the healthcare professional and ensure patient comfort.
2. How it works: exo/endocervical sampling for liquid-based cytology
The brush is inserted into the cervical canal and gently rotated to simultaneously exfoliate and retain cells from the endocervix and ectocervix: the long filaments collect endocervical cells and the short filaments, ectocervical cells. In liquid-based cytology the sample is released directly into the pre-filled vial with cell preservative, eliminating the drying artefacts of the conventional smear and optimising morphological reading in thin layer.
Operating mode (manufacturer’s summary):
- Insert the brush into the cervix and take the sample from the exo-endocervical transition zone.
- Rotate 5 times clockwise with light pressure and remove carefully avoiding contact with the speculum.
- Place the brush in the pre-filled vial with cell preservative and shake it.
- Separate the brush head by pressing the sleeve slightly downwards: the head detaches by itself.
- Remove the sleeve, close the vial and identify the patient.
For use by healthcare professionals only. Contraindicated from the tenth week of pregnancy. Not recommended for conventional cytology: designed for thin-layer / liquid-based techniques (LBC).
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Type | Single-use exo/endocervical cytological brush |
| Reference | 0658046 |
| Handle material | Polypropylene (PP) |
| Head material | Low-density polyethylene (PE-LD) |
| Handle length | 170 ± 2 mm |
| Handle diameter | 5 mm |
| Latex | Latex-free |
| Sterility | Non-sterile |
| Use | Single-use / disposable |
| System | Liquid-based cytology (LBC), thin layer, classification according to the Bethesda system |
| Detachable head | Yes (it detaches by pressing the sleeve to deposit it in the vial with preservative) |
| Presentation | Box of 100 units (plastic bag) |
| Outer packaging | 2,500 units |
| Expiry | 5 years from date of manufacture |
| Unit EAN code | 8437011999214 |
| Packaging EAN code | 8437011999221 |
| Marking | CE 0197 |
Cytological classification according to the Bethesda system (basis of the descriptive diagnosis of the thin-layer smear):
| Type of lesion | Description |
|---|---|
| Low-grade intraepithelial lesion | Groups together HPV infection and mild dysplasia (CIN 1) |
| High-grade intraepithelial lesion | Groups together moderate (CIN II) and severe (CIN III) dysplasia |
| Invasive squamous cell carcinoma | Invasive carcinomas |
4. Equivalences and Cross-References
The following references correspond to endocervical cytobrushes from other manufacturers verified against official sources (manufacturer’s catalogue and IFU and GUDID regulatory database). All are considered comparable at category level, not interchangeable 1:1: they share the rotational sampling principle and use in liquid-based cytology, but differ in head geometry, presentation or accessories.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| CooperSurgical® (Medscand®) | Cytobrush Plus® GT | C0104 (box of 100, non-sterile) | Comparable by category (not interchangeable 1:1) | Head with Gentle-Touch protective bulb versus free filaments; same endocervical indication and LBC compatibility. Code confirmed on official website and GUDID. |
| Rovers Medical Devices | EndoCervex-Brush® | 380100703 / 380100731 | Comparable by category (not interchangeable 1:1) | Single piece with 600 fine bristles and safety ring; requires verification of the presentation (sterile/non-sterile) of each pack. Codes confirmed in the manufacturer’s official IFU. |
| Fisher Scientific (Fisherbrand™) | EndoCervex-Brush | 14959103 (box of 50) | Comparable by category (not interchangeable 1:1) | Same exo/endocervical sampling technique; 50-unit format and non-sterile. Code confirmed in GUDID. |
There is no equivalence table validated by the manufacturer that cross-references this reference with the brands mentioned; the above correspondences are documented functional comparisons against official sources (each manufacturer’s catalogue and IFU and GUDID database). Consult the technical department before using an alternative reference in a tender or protocol.
5. Selection tips and variants of interest
- For sampling under strict aseptic conditions, consider the sterile version of the same family (ref. 0658089, box of 100 units).
- The detachable head allows the sample to be left in the vial without manual contact, ideal when transport to the laboratory is prolonged or when preserving sample integrity is required.
- Verify the brush’s compatibility with the liquid preservation medium used by your laboratory (liquid-based cytology / thin-layer preservatives).
- In patients with cervical stenosis, atrophic cervix or narrow anatomy, consider cytobrushes with a smaller diameter (3.5 mm), such as the references from the PN/PS1643520 and PN/PS3653520 series.
- For simultaneous endo/ectocervical collection with a 17 cm long handle, Cahnos offers the PM-CARE® ENDOEXO cytobrush (ref. PN3742519); for a 5 mm conical head, the PS/PN1655020 and PS/PN3665020 series.
- Single-use product: do not reuse. Reuse may cause contamination and erroneous diagnoses. Dispose of waste in accordance with current regulations.





Reviews