We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reusable handle for Bovie Change-A-Tip «AA» electrocautery (thermocautery) with included non-sterile fine tip – Ref. 30590 (1 unit)

48,45 €

Reusable handle for Bovie Change-A-Tip «AA» thermocautery (electrocautery), ref. 30590, with included non-sterile fine high-temperature tip. Powered by replaceable AA batteries, it operates completely independently, without an external electrosurgical generator or neutral plate. Its recessed power button reduces the risk of accidental activation, and its design allows the end to be detached to remove the batteries safely and effectively. It accepts all interchangeable tips in the series (sterile 30568, 30569, 30570, 30571 and 30576, as well as non-sterile 30584 and 30590), without the need for sterilisation. Ideal for haemostasis and precision cauterisation in dermatology, ENT, gynaecology, cardiology and minor surgery. Class II B medical device. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30590

Description

1. Bovie Change-A-Tip «AA» handle: the reusable working body of your thermocautery

The Bovie Change-A-Tip «AA» handle (ref. 30590) is the reusable component of the most versatile battery-powered electrocautery system from the Italian company: a portable high-temperature thermocautery that allows cauterising and achieving targeted haemostasis without relying on external electrosurgical generators or a neutral plate. It includes a fine, non-sterile, high-temperature tip ready for use and is recommended for all interchangeable tips in the series, so a single handle lets you tackle procedures in dermatology, ENT, gynaecology, cardiology, vasectomy and minor surgery with complete autonomy. As it requires no sterilisation and accepts replaceable batteries, it becomes the simplest and most cost-effective solution for equipping consulting rooms, operating theatres and outpatient minor surgery rooms.

2. What the Change-A-Tip system is and how it works

The Bovie thermocautery generates heat by resistive effect at the tip when activated with the batteries, reaching a high temperature at the point of contact that allows coagulating small vessels and achieving rapid, targeted haemostasis with excellent control of the treated area. This handle incorporates a recessed power button that reduces the risk of accidental activation and an improved design that allows detaching the handle end to remove the batteries safely and efficiently once depleted.

  • Change-A-Tip system: interchangeable high-temperature tips (sterile, except for the non-sterile ones from refs. 30584 and 30590).
  • Replaceable batteries: autonomous operation, without cables or external generator.
  • Reusable handle: only the tips need replacing, optimising the cost per procedure.
  • No sterilisation required: ready to use and maintain with a simple tip change.

3. Technical Specifications

Main characteristics

Manufacturer reference Ref. 30590 (SKU GM30590)
Product type Reusable battery-powered thermocautery (electrocautery) handle, Change-A-Tip system
Tip included Fine high-temperature tip, non-sterile
Tip system Interchangeable – recommended for all tips in the series
Power supply Replaceable batteries (AA batteries)
Activation Recessed power button (reduces the risk of accidental activation)
Battery removal Detachable handle end for safe and efficient battery removal
Sterilisation Not required
Handle Reusable

Product data

Manufacturer GIMA
Sales unit 1 unit (1 pc)
Device type Medical device (medical device)
Device class II B
CND K0299
GMDN 18011
EAN 8023279305906

Available references from the Bovie family

Reference Component Details
30584 Complete Change-A-Tip kit 1 handle + 4 non-sterile tips (2 loop 30568 + 2 fine 30571) + 2 AA alkaline batteries, in padded case
30568 High-temperature loop tip Sterile, box of 10 units – recommended for DER/ENT
30569 Flexible loop tip 2″ Sterile, box of 10 units – recommended for GYN/ENT
30570 Long loop tip 5″ Sterile, box of 10 units – recommended for gynaecology
30571 Fine high-temperature tip Sterile, box of 10 units – recommended for DER/CARDIO
30576 Elongated tip Sterile, box of 10 units – recommended for vasectomy
30579 High-temperature electrocautery Fixed fine tip – recommended for DER/Cardio
30588 High-temperature electrocautery Fixed loop tip – recommended for DER/ENT
30598 High-temperature handle 1,200 °C «AA» handle without tip, compatible with nickel-chromium wire tips 30599/30600/30601

4. Equivalences and Cross-References

No validated official equivalence table cross-referencing reference 30590 with other manufacturers’ codes has been found in reliable sources. The verified correspondences are established within the Bovie family itself: the reusable Change-A-Tip handle (30590) is interchangeable with the complete Change-A-Tip kit (30584) and compatible with the sterile replacement tips 30568, 30569, 30570, 30571 and 30576 (box of 10 units), as well as with the non-sterile tips 30568 and 30571 included in kit 30584. At category level, the concept of a high-temperature disposable thermocautery is comparable to the Bovie® line from Aspen Surgical, although the tip attachment system and the battery type must be checked with Cahnos’s technical-commercial service before any replacement.

5. Selection tips and variants of interest

  • Choose the tip geometry according to the technique: fine tip (30571) for precision haemostasis in dermatology and cardiology; loop (30568) for small-calibre resections and dissections in dermatology and ENT; flexible loop (30569) and long loop (30570) for gynaecology and ENT; elongated tip (30576) for vasectomy.
  • If you need a complete starter solution, combine this handle with the Change-A-Tip kit (30584), which provides non-sterile tips and AA batteries in a padded case.
  • To equip several rooms with the same system, combine the reusable 30590 handle with the sterile replacement tips 30568, 30569, 30570, 30571 and 30576.
  • If you prefer fixed-tip equipment, the family offers models 30579 (fine tip) and 30588 (loop tip); for temperatures up to 1,200 °C with nickel-chromium wire tips, consider the 30598 handle.
  • The tips are single-use: do not re-sterilise or reuse. The handle is reusable and requires no sterilisation; only replace the batteries when they run out.

For large orders you can request a quote: consult your technical-commercial advisor at Cahnos for terms and volumes.

Additional information

Manufacturer reference

ref. 30590 (SKU GM30590)

Sales unit

1 unit (1 pc)

Device type

Medical device (medical device)

CND code

K0299

GMDN code

18011

EAN

8023279305906

Product type

Reusable battery-powered thermocautery (electrocautery) handle, Change-A-Tip system

Power supply

Replaceable batteries (AA batteries)

Tip included

Fine high-temperature tip, non-sterile

Tip system

Interchangeable – recommended for all tips in the series

Activation

Recessed power button (reduces accidental activation)

Battery removal

Detachable handle end for safe and efficient battery removal

Sterilisation

Not required

Handle

Reusable

Tip compatibility

Sterile tips 30568, 30569, 30570, 30571, 30576; non-sterile 30568 and 30571 (kit 30584)

Application

Dermatology, ENT, gynaecology, cardiology, vasectomy and minor surgery

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Reusable handle for Bovie Change-A-Tip «AA» electrocautery (thermocautery) with included non-sterile fine tip – Ref. 30590 (1 unit)”

Your email address will not be published. Required fields are marked *