Description
1. Product Presentation
The disposable electrosurgery electrode Ref. F4044/TEF is the reference coagulation tip when clean, safe and effective contact haemostasis is required in medium-depth surgical fields. Its 4 mm sphere with non-stick Teflon (PTFE) coating slides over tissue without dragging carbonised eschar, reduces interruptions to clean the tip and maintains stable performance throughout the procedure. Each box includes 24 sterile single-use units, with individually heat-sealed packaging that preserves sterility until the moment of surgery: the most hygienic and cost-effective solution for hospitals, private clinics, ambulatory surgery centres and minor surgery clinics.
2. Technical explanation and operation
The F4044/TEF acts as the active electrode of a monopolar electrosurgery system: the radiofrequency current generated by the electrosurgical unit (ESU) travels to the spherical tip and concentrates at the point of contact with the tissue, producing contact coagulation and controlled fulguration with less carbonisation of adjacent tissue than other tip geometries. The circuit is closed through the neutral (dispersive) plate placed on the patient.
- Sphere tip Ø 4 mm: large contact surface, ideal for coagulating and sealing soft tissue and small vessels with controlled energy delivery.
- Teflon (PTFE) coating on the active area: non-stick (antisticking) effect that minimises adherence of slough, reduces eschar and surgical smoke and prolongs tip performance without frequent cleaning.
- Total length 70 mm: adequate reach for open surgery, dermatology, minor surgery and medium-depth surgical fields.
- 2.38 mm (3/32″) shaft with anti-rotation hexagonal locking: universal fixation standard, compatible with virtually all pencils and electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe type and compatible), without the need for adapters.
- Sterile single-use: eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.
3. Technical Specifications
| Specification | Detail |
|---|---|
| Reference / SKU | F4044/TEF |
| Product type | Disposable monopolar electrosurgery electrode, ball tip |
| Ball diameter | 4 mm |
| Total length | 70 mm |
| Electrode material | AISI stainless steel with Teflon (PTFE) coating on the active area |
| Coating | Non-stick Teflon (PTFE) |
| Shaft diameter | 2.38 mm (3/32″) — universal standard |
| Fixation system | Anti-rotation hexagonal lock |
| Compatibility | Pencils and electrosurgical units with universal 2.38 mm (3/32″) fitting, type Valleylab, ConMed, Bovie, Erbe and compatible |
| Use | Disposable, single-use |
| Sterilisation | Ethylene oxide (EO) |
| Sterility | Sterile, individually heat-sealed packaging |
| Latex | Latex-free |
| Presentation | Box of 24 units |
| Shelf life / storage | 4 years from the date of manufacture |
| Classification | Medical device class IIb · CE marking (Directive 93/42/EEC) |
Variants of the same family (Teflon coating, 2.38 mm shaft, box of 24 units):
| Reference | Length | Tip shape |
|---|---|---|
| F4044/TEF (this product) | 70 mm | Sphere Ø 4 mm |
| F4067/TEF | 150–156 mm | Sphere Ø 4 mm |
| F4046/TEF | 70 mm | Blade |
| F4048/TEF | 70 mm | Needle |
| F4053/TEF | 100 mm | Blade |
| F4050/TEF | 150–153 mm | Blade |
| F4052/TEF | 150–152 mm | Needle |
Compatibility note: verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal locking; virtually all electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe and compatible) accept it without adapters.
4. Equivalences and Cross-References
The reference F4044/TEF is a factory code verified on the manufacturer’s official website. No official manufacturer cross-reference table has been found in public sources validating an exact 1:1 equivalence of this 4 mm sphere electrode with those of other brands. The following rows are functional comparisons verified against official catalogues, manufacturer websites and the GUDID/FDA regulatory database, and should be treated as comparable at category level, not 1:1 interchangeable without validation by the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Bovie / Aspen Surgical (Symmetry Surgical, USA) | Resistick II™ Coated Standard Ball Electrode, PTFE-coated | ES21T (4 mm ball × 2″ / 5.08 cm, box of 12) | Comparable by category (not interchangeable 1:1) | Same 4 mm sphere with non-stick PTFE coating (Resistick II) and standard 3/32″ (≈2.3 mm) shaft, sterile and single-use; the shaft length (5.08 cm vs 70 mm) and presentation (box of 12 vs 24) differ. Code and attributes verified in GUDID/FDA (class II, sterile) and manufacturer’s catalogue. |
| Prima Medical (United Kingdom) | NonStick™ ball electrode, 4 mm sphere, single-use | PMS 2907 (4 mm × 110 mm sphere, pack of 10) | Comparable by category (not interchangeable 1:1) | Same single-use 4 mm sphere with non-stick behaviour; the length (110 mm vs 70 mm) and presentation (pack of 10 vs box of 24) differ. Code and attributes verified in the manufacturer’s official catalogue. |
| Prima Medical (United Kingdom) | NonStick™ ball electrode, 4 mm sphere, long version, single-use | PMS 2907L (4 mm × 130 mm sphere, pack of 10) | Comparable by category (not interchangeable 1:1) | Same non-stick 4 mm sphere in long version; the length (130 mm vs 70 mm) and presentation (pack of 10 vs box of 24) differ. Code and attributes verified in the manufacturer’s official catalogue. |
There is no manufacturer-validated equivalence table; consult the technical department before use in tenders. Before any substitution, check field by field: sphere diameter (4 mm exact), total length (70 mm), shaft diameter (2.38 mm / 3/32″), fixation system (hexagonal locking), coating (Teflon/PTFE), sterility and presentation. The third-party codes cited have been verified in public sources (GUDID/FDA and official catalogues) and correspond to electrodes of the same category, not certified 1:1 equivalents.
5. Selection tips and variants of interest
The choice of tip geometry should be based on the surgical technique and the tissue to be treated. The 4 mm sphere of the F4044/TEF is indicated for contact coagulation and haemostasis of broad surfaces and soft tissue in medium-depth accesses (70 mm), such as open surgery, dermatology and minor surgery. If you need greater reach for deep fields, reference F4067/TEF offers the same Teflon spherical tip with a length of 150 mm. For cutting surgery, the Teflon family is completed with the blades F4046/TEF (70 mm), F4053/TEF (100 mm) and F4050/TEF (150 mm); and for precision dissection and targeted haemostasis, with the needles F4048/TEF (70 mm) and F4052/TEF (150 mm).
In applications where cost per procedure is prioritised, the stainless steel electrode F4044 offers the same 4 mm sphere in a short uncoated format; the F4044T (titanium) version provides an alternative non-stick behaviour with greater corrosion resistance. Always verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal locking: Valleylab, ConMed, Bovie, Erbe and compatible electrosurgical pencils accept it. This is a single-use product: do not re-sterilise or reuse. For institutional volumes, supply agreements or tenders, consult our technical-commercial department.