Description
1. Product Presentation
The reusable electrosurgery electrode Reference F4045 is the active tip your operating theatre needs for reliable, reproducible and precise coagulation in every procedure. Its Ø4 mm sphere concentrates high-frequency energy on a rounded surface, ideal for working on soft tissue, small vessels and bleeding beds with control, less carbonisation and reduced lateral thermal damage compared to needle or blade tips.
Being reusable and autoclavable, the same electrode can be used for multiple sterilisation cycles with consistent performance, significantly reducing the cost per procedure in hospitals, private clinics, minor surgery practices and ambulatory surgery centres. It is supplied in a box of 5 units (non-sterile), the ideal refill format to equip the electrosurgery cart and keep the operating theatre stock always available.
2. Technical explanation of the equipment and procedure
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil (electrosurgical unit) to the active electrode, which concentrates the energy at the point of contact with the tissue; the circuit is closed via the neutral (dispersive) plate placed on the patient. Depending on the tip geometry, the predominant effect is cutting, coagulation or mixed.
The Ø4 mm sphere (ball) tip is designed for contact coagulation, desiccation and controlled fulguration: its rounded shape distributes the current over a larger surface area and by contact, achieving effective haemostasis of small vessels and bleeding beds with reduced lateral thermal damage. It is the classic configuration for cauterisation of delicate surfaces, dermatological surgery, small haemorrhages and haemostasis touch-ups at the end of the procedure. In this 156 mm straight geometry version, the electrode offers a wide reach, very useful in deep surgical fields with direct access.
The electrode is mounted on a Ø2.38 mm (3/32″) shaft, the industry standard diameter for pencil electrodes, ensuring compatibility with virtually all handpieces, pencils and electrosurgical units with universal fitting, without the need for adapters. Its stainless steel construction with insulating anti-shock handle allows sterilisation in autoclave and reuse for numerous cycles, provided the sterilisation centre protocols are followed.
3. Technical Specifications
Technical features of the reusable electrosurgery electrode Reference F4045:
| Characteristic | Specification |
|---|---|
| Reference / SKU | F4045 (distribution code Cahnos, reusable sphere Ø4 mm family) |
| Product type | Reusable monopolar electrosurgery electrode, sphere tip |
| Tip shape | Sphere (ball) |
| Ball diameter | Ø4 mm |
| Total length | 156 mm |
| Working angle | Straight (0°) |
| Shaft diameter | 2.38 mm (3/32″) — universal standard |
| Material | Stainless steel (tip) · anti-shock insulation on handle |
| Type of use | Reusable · autoclavable |
| Sterilisation | Autoclave (multiple cycles) |
| Compatibility | Pencils and electrosurgical units with universal 2.38 mm (3/32″) housing |
| Latex | Latex-free |
| Presentation | Box of 5 units (non-sterile) |
The universal 2.38 mm (3/32″) connection allows its use interchangeably in push-button, foot-switch and reusable pencils with standard fitting, both those included in the electrosurgery catalogue and most equipment on the market, without the need for adapters.
Variants of the same reusable sphere tip family (shaft 2.38 mm / 3/32″):
| Reference | Length | Tip shape | Angle |
|---|---|---|---|
| F4045 (this product) | 156 mm | Sphere Ø4 mm | Straight (0°) |
| F4045/10 | 156 mm | Sphere Ø4 mm | 10° |
| F4045/20 | 156 mm | Sphere Ø4 mm | 20° |
| F4045/30 | 156 mm | Sphere Ø4 mm | 30° |
| F4045/40 | 156 mm | Sphere Ø4 mm | 40° |
| F4068 | 70 mm | Sphere Ø4 mm | Straight (0°) |
| F4064 | 150 mm | Sphere Ø2.5 mm | Straight (0°) |
4. Equivalences and Cross-References
Reference F4045 is a proprietary distribution code of Cahnos within the family of reusable Ø4 mm sphere electrodes with 2.38 mm (3/32″) shaft. No equivalence table validated by the manufacturer has been found in public sources, regulatory databases (GUDID/FDA, EUDAMED) or official catalogues that cross-references this exact configuration (Ø4 mm sphere + 156 mm + straight + 2.38 mm shaft + reusable) with identical 1:1 codes from other brands. The following rows are functional comparisons verified against the official catalogue of each cited manufacturer and the GUDID/FDA regulatory database, and should be treated as comparable at category level, not interchangeable 1:1 without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Bovie / Aspen Surgical (USA) | Reusable ball electrode, 3/32″ shaft | A832M | Comparable by category (not interchangeable 1:1) | Reusable monopolar ball-tip electrode with standard 3/32″ (2.3–2.4 mm) shaft, non-sterile packaging ready for autoclave sterilisation (5–25 cycles). Matches in category, material and shaft diameter; differs in exact sphere diameter, total length and commercialisation (unit vs. box of 5). Code and attributes verified in GUDID/FDA (model A832M, Aspen Surgical Products, Inc.; UDI 00840113234585). |
| Bovie / Aspen Surgical (USA) | Reusable 3 mm ball electrode with extended shaft | ES06R | Comparable by category (not interchangeable 1:1) | Reusable monopolar ball electrode with standard 3/32″ (2.36 mm) shaft and extended length for deep fields. Matches in category, material, shaft and spherical tip philosophy; differs in sphere diameter (Ø3 mm vs. Ø4 mm) and presentation. Code and attributes verified in GUDID/FDA (model ES06R, Aspen Surgical Products, Inc.; UDI 00840113235018). |
| Gima (Italy) | Autoclavable straight sphere Ø3 mm electrode, Ø2.4 mm shaft | 30510 / 30530 | Comparable by category (not interchangeable 1:1) | Autoclavable stainless steel sphere electrode (up to 20 cycles) with Ø2.4 mm shaft, for monopolar handpieces from the Gima range. Matches in category, material and tip philosophy; differs in sphere diameter (Ø3 mm vs. Ø4 mm), length, straight geometry and nominal shaft diameter (2.4 mm vs. 2.38 mm). Codes and attributes verified in the official Gima catalogue. |
| ConMed (USA) | Hyfrecator, reusable ball electrode | 7-222-A | Comparable by category (not interchangeable 1:1) | Reusable ball electrode with 3/32″ shaft; differs in shaft geometry (angled shaft at 30° vs. straight), total length (approx. 53 mm vs. 156 mm) and connection system oriented to the Hyfrecator family. Code and attributes verified in ConMed catalogue and authorised distribution. |
There is no equivalence table validated by the manufacturer; consult with the technical department before use in tenders. Before any substitution, check field by field: sphere diameter (Ø4 mm), total length (156 mm), working angle (straight, 0º), shaft diameter (2.38 mm / 3/32″), autoclave sterilisation capacity and regulatory classification of the actual product. Comparable families in the sector that should be evaluated with the technical data sheet or IFU in hand include reusable ball electrodes from Medtronic / Valleylab (Covidien) and autoclavable spherical tips from other European manufacturers with 2.4 mm shaft.
5. Selection tips and variants of interest
Choose the tip geometry according to the desired effect and surgical access: the straight Ø4 mm ball tip, 156 mm (F4045), is the contact coagulation option with wide reach and direct access. If you need to orient the ball tip towards lateral bleeding without straining the surgeon’s wrist, angled versions are available: F4045/10 (10º), F4045/20 (20º), F4045/30 (30º) and F4045/40 (40º), all in 156 mm. If you prefer a wide coagulation surface in a short format, the same family offers the Ø4 mm ball tip, 70 mm (F4068), and the Ø2.5 mm ball tip in 150 mm (F4064) provides finer, precision coagulation for delicate surfaces.
For cutting and dissection, the reusable family with a 2.38 mm shaft is completed with blades F4060 (69 mm), F4053R (100 mm), F4062 (curved blade, 150 mm) and F4065 (153 mm), and with needles F4084 (Ø0.75 mm, 69 mm), F4063 (Ø0.78 mm, 152 mm), F4066 (Ø1.30 mm, 152 mm), F4086 (Ø1.30 mm, 69 mm) and F4061 (angled round needle 20º, 100 mm).
Always verify that your pencil accepts a 2.38 mm (3/32″) shaft: the vast majority of electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe and compatible) accept it, both finger-switch and foot-pedal models. As a reusable product, follow your facility’s internal cleaning, disinfection and sterilisation protocols and remove the electrode at any sign of deterioration of the tip or insulation. The sterile tip cleaner F7520 and the sterile sheath for pencils F4545 are recommended as complementary accessories. For institutional volumes, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.